2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distance.

A method of tomographic phase retrieval is developed for multi-material objects whose components each has a distinct complex refractive index. The phase-retrieval algorithm, based on the Transport-of-Intensity equation, utilizes propagation-based X-ray phase contrast images acquired at a single defocus distance for each tomographic projection. The method requires a priori knowledge of the complex refractive index for each material present in the sample, together with the total projected thickness of the object at each orientation. The requirement of only a single defocus distance per projection simplifies the experimental setup and imposes no additional dose compared to conventional tomography. The algorithm was implemented using phase contrast data acquired at the SPring-8 Synchrotron facility in Japan. The three-dimensional (3D) complex refractive index distribution of a multi-material test object was quantitatively reconstructed using a single X-ray phase-contrast image per projection. The technique is robust in the presence of noise, compared to conventional absorption based tomography.

[1]  S. Wilkins,et al.  Contrast and resolution in imaging with a microfocus x-ray source , 1997 .

[2]  Gilles Peix,et al.  Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam , 1999 .

[3]  A R Sovijärvi,et al.  Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent. , 2001, Physics in medicine and biology.

[4]  Aimin Yan,et al.  X-ray phase-attenuation duality and phase retrieval. , 2005, Optics letters.

[5]  Lorenzo Crocco,et al.  Inverse scattering from phaseless measurements of the total field on open lines. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  Andrei V. Bronnikov,et al.  Reconstruction formulas in phase-contrast tomography , 1999 .

[7]  Attila Kovacs,et al.  Recent advances in imaging the lungs of intact small animals. , 2004, American journal of respiratory cell and molecular biology.

[8]  Bastiaan Driehuys,et al.  Imaging Techniques for Small Animal Models of Pulmonary Disease: MR Microscopy , 2007, Toxicologic pathology.

[9]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[10]  Zwi Barnea,et al.  Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation , 2001 .

[11]  Lorenzo Crocco,et al.  Phaseless imaging with experimental data: facts and challenges. , 2008, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Lucia Mancini,et al.  Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA , 2005 .

[13]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[14]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[15]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[16]  M. Teague Deterministic phase retrieval: a Green’s function solution , 1983 .

[17]  T. Gureyev,et al.  The binary dissector: phase contrast tomography of two- and three-material objects from few projections. , 2008, Optics express.

[18]  Lorenzo Crocco,et al.  Faithful non-linear imaging from only-amplitude measurements of incident and total fields. , 2007, Optics express.

[19]  K. Nugent,et al.  Phase retrieval with the transport-of-intensity equation. II. Orthogonal series solution for nonuniform illumination , 1996 .

[20]  K. Umetani,et al.  Construction and commissioning of a 215-m-long beamline at SPring-8 , 2001 .

[21]  E. Förster,et al.  Double crystal diffractometry for the characterization of targets for laser fusion experiments , 1980 .

[22]  P. Cloetens,et al.  Mixed transfer function and transport of intensity approach for phase retrieval in the Fresnel region. , 2007, Optics letters.

[23]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[24]  S. Wilkins,et al.  X-ray phase-contrast microscopy and microtomography. , 2003, Optics express.

[25]  S. Wilkins,et al.  Phase-and-amplitude computer tomography , 2006 .

[26]  P. Cloetens,et al.  Phase objects in synchrotron radiation hard x-ray imaging , 1996 .

[27]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[28]  William Thomlinson,et al.  Quantitative measurement of regional lung gas volume by synchrotron radiation computed tomography , 2005, Physics in medicine and biology.

[29]  K. Nugent,et al.  Rapid quantitative phase imaging using the transport of intensity equation , 1997 .

[30]  K. Nugent,et al.  Noninterferometric phase imaging with partially coherent light , 1998 .

[31]  K K W Siu,et al.  Dynamic measures of regional lung air volume using phase contrast x-ray imaging , 2008, Physics in medicine and biology.

[32]  A. Bronnikov,et al.  Theory of quantitative phase-contrast computed tomography. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.