Development of evanescent wave all-fiber immunosensor for environmental water analysis.

A compact and portable evanescent wave all-fiber immunosensor is developed, which employs a novel single-multi-mode fiber optic coupler for exciting and collecting fluorescence emission from the fiber optic probe. Combination tapered fiber probes are produced by tube-etching method and the best tapered ratio of the probe determined is approximately 0.37. Calibration curves obtained for 2,4-dichlorophenoxyacetic acid (2,4-D) and Microcystin-LR (MC-LR) have detection limits of 0.09 microgL(-1)and 0.03 microgL(-1), respectively. The 50% inhibition concentration (IC(50)) for MC-LR and 2,4-D were 1.12+/-0.01 microgL(-1)and 3.81+/-0.03 microgL(-1), respectively. A reusable immunosurface is provided via the covalent attachment of the analyte derivative to a self-assembled monolayer formed onto the fiber optic probe. The regeneration of the sensor surface allows the performance of more than 100 assay cycles within an analysis time of about 20 min for each assay cycle.

[1]  J. Homola Present and future of surface plasmon resonance biosensors , 2003, Analytical and bioanalytical chemistry.

[2]  N. Nath,et al.  Evanescent wave fiber optic fluorosensor: effect of tapering configuration on the signal acquisition , 1998 .

[3]  F. Ligler,et al.  Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor. , 1999, Biosensors & bioelectronics.

[4]  C Barzen,et al.  Part per trillion level determination of isoproturon in certified and estuarine water samples with a direct optical immunosensor , 2001 .

[5]  Dietrich Marcuse,et al.  Launching light into fiber cores from sources located in the cladding , 1988 .

[6]  Francesco Baldini,et al.  Antibody immobilisation on fibre optic TIRF sensors. , 2003, Biosensors & bioelectronics.

[7]  D. Demarco,et al.  Detection of Escherichia coli O157:H7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides. , 2002, Journal of food protection.

[8]  F. Spener,et al.  Development of an amperometric flow injection immunoanalysis system for the determination of the herbicide 2,4-dichlorophenoxyacetic acid in water. , 1997, Biosensors & bioelectronics.

[9]  R. Puchades,et al.  Optical immunosensors for environmental monitoring: How far have we come? , 2006, Analytical and bioanalytical chemistry.

[10]  J M Calvert,et al.  Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces. , 1989, Analytical biochemistry.

[11]  A. Waggoner,et al.  Cyanine-labeling reagents: sulfobenzindocyanine succinimidyl esters. , 1996, Bioconjugate chemistry.

[12]  F. Ligler,et al.  An evanescent wave biosensor. I. Fluorescent signal acquisition from step-etched fiber optic probes , 1994, IEEE Transactions on Biomedical Engineering.

[13]  C. MacKintosh,et al.  Purification of type 1 protein (serine/threonine) phosphatases by microcystin‐Sepharose affinity chromatography , 1994, FEBS letters.

[14]  F. Ligler,et al.  An evanescent wave biosensor. II. Fluorescent signal acquisition from tapered fiber optic probes , 1994, IEEE Transactions on Biomedical Engineering.

[15]  Miao He,et al.  A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodies. , 2006, Analytica chimica acta.

[16]  J. Andrade,et al.  Remote fiber-optic biosensors based on evanescent-excited fluoro-immunoassay: Concept and progress , 1985, IEEE Transactions on Electron Devices.

[17]  H. M. Widmer,et al.  Fiber-optic Atrazine immunosensor☆ , 1993 .

[18]  C. Barzen,et al.  Optical multiple-analyte immunosensor for water pollution control. , 2002, Biosensors & bioelectronics.

[19]  D. Barceló,et al.  Sampling of polar pesticides from water matrices , 1997 .

[20]  Frances S. Ligler,et al.  Portable multichannel fiber optic biosensor for field detection , 1997 .

[21]  David W. Conrad,et al.  Detection of TNT in Water Using an Evanescent Wave Fiber-Optic Biosensor , 1995 .

[22]  L. Mosiello,et al.  A fibre-optic immunosensor for 2,4-dichlorophenoxyacetic acid detection , 1997 .

[23]  L M Lechuga,et al.  Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor. , 2006, Biosensors & bioelectronics.

[24]  Frances S. Ligler,et al.  A fiber optic biosensor: combination tapered fibers designed for improved signal acquisition , 1993 .