The Integrated Effect of Medical Lamp Position and Diffuser Discharge Velocity on Ultra-clean Ventilation Performance in an Operating Theatre

The ventilation system of an operating theatre (OT) in a hospital needs to provide a comfortable and healthy surgical environment, particularly to minimise the risk of airborne infection. Engineering standards are available to outline specialised ventilation design and installation requirements based on knowledge accumulated from quality research and day-to-day practices. In this paper, the integrated effect of a reduction in supply air velocity and changed medical lamp positions on the ultra-clean ventilation performance of a standard OT environment is reported. The dispersion of infectious particles from both the surgical team and the patient were examined through computational fluid dynamic analysis. It was observed that variations in supply velocity and medical lamp configuration will only slightly affect the thermal comfort environment. However, they could have a serious effect on the movement of infectious particles and hence increase the cross infection risk.

[1]  R. W. Rasmussen,et al.  Ventilation requirements in hospital operating rooms. I: Control of airborne particles , 1986 .

[2]  John Colquhoun,et al.  Computational Fluid Dynamics Applications in Hospital Ventilation Design , 2003 .

[3]  Henning Rüden,et al.  The Influence of Various Air Exchange Rates on Airborne Particles and Microorganisms in Conventionally Ventilated Operating Rooms , 1996 .

[4]  D. Dunn-Rankin,et al.  Transport of surgically produced aerosols in an operating room. , 1998, American Industrial Hygiene Association journal.

[5]  N. Zamuner Operating room environment with turbulent airflow , 1986 .

[6]  Jan van der Linden,et al.  Wound Ventilation With Ultraclean Air for Prevention of Direct Airborne Contamination During Surgery , 2004, Infection Control & Hospital Epidemiology.

[7]  Tin-Tai Chow,et al.  Performance of ventilation system in a non-standard operating room , 2003 .

[8]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[9]  Nhs Estates Ventilation in Healthcare Premises , 1994 .

[10]  P J Borm,et al.  Simulation of nitrous oxide concentrations in operating and recovery rooms. , 1990, The Annals of occupational hygiene.

[11]  Qingyan Chen,et al.  Control of Airborne Particle Concentration and Draught Risk in an Operating Room , 1992 .

[12]  O M Lidwell,et al.  Suggested bacteriological standards for air in ultraclean operating rooms. , 1983, The Journal of hospital infection.

[13]  J. Charnley,et al.  SECTION II GENERAL ORTHOPAEDICS Postoperative Infection after Total Hip Replacement with Special Reference to Air Contamination in the Operating Room , 1972, Clinical orthopaedics and related research.

[14]  Chia-Jung Hsu Numerical Heat Transfer and Fluid Flow , 1981 .

[15]  B Friberg,et al.  Mobile zoned/exponential LAF screen: a new concept in ultra-clean air technology for additional operating room ventilation. , 2002, The Journal of hospital infection.

[16]  Monika Woloszyn,et al.  Diagonal air-distribution system for operating rooms: experiment and modeling , 2004 .