Evaluation of a new rapid and fully automated electrochemiluminescence immunoassay for thyrotropin receptor autoantibodies.

BACKGROUND Hyperthyroidism in Graves' disease is caused by autoantibodies to the TSH receptor (TSHR), and measurement of the TSHR autoantibody (TRAb) yields important information to diagnose and decide on the course of treatment of Graves' disease. We evaluated basic and clinical performance of a new, rapid, and fully automated electrochemiluminescence immunoassay Elecsys Anti-TSHR (Elecsys TRAb) for measuring serum TRAb. METHODS For evaluation of basic performance of the assay, we carried out intra- and interassay precision studies using five serum pools and three serum pools, respectively, and the assay was compared with four commercial TRAb assays. Clinical performance of the assay was evaluated with sera from 298 patients with untreated Graves' disease, 220 patients with destructive (painless and subacute) thyroiditis, and 332 healthy volunteers. The optimal cutoff point, which was calculated by receiver operating characteristic (ROC) analysis with the above subjects, was then used to classify an independent sample set of 80 patients with untreated Graves' disease, and 152 patients with destructive thyroiditis. RESULTS Intraassay coefficient of variation (CV) was 4.24% at 1.85 IU/L and interassay CV was 10.1% at 1.46 IU/L. All the correlation coefficient values calculated against four commercial assays were larger than 0.85. ROC analysis resulted in a specificity of 99.1% with a sensitivity of 97.0% at a decision limit of 1.86 IU/L from comparison with untreated Graves' disease and destructive thyroiditis. The cutoff point yielded a sensitivity of 87.5% and specificity of 96.7% with the independent sample set. CONCLUSION In spite of the short measuring time of only 27 minutes, the assay showed the same or better results with the existing commercial products. The short measuring time would contribute to speedy, preconsultation diagnosis of thyroid disease, especially of Graves' disease.

[1]  A. Miyauchi,et al.  Quantitative measurement of anti-TSH receptor antibodies is useful for the evaluation of treatment effect. , 2007, Thyroid.

[2]  Megumi Tanaka,et al.  Clinical evaluation of 3rd generation assay for thyrotropin receptor antibodies: the M22-biotin-based ELISA initiated by Smith. , 2005, Endocrine journal.

[3]  D. Weightman,et al.  A new assay for thyrotropin receptor autoantibodies. , 2004, Thyroid : official journal of the American Thyroid Association.

[4]  T. Blundell,et al.  Characteristics of a human monoclonal autoantibody to the thyrotropin receptor: sequence structure and function. , 2004, Thyroid : official journal of the American Thyroid Association.

[5]  B. Smith,et al.  Human monoclonal thyroid stimulating autoantibody , 2003, The Lancet.

[6]  K. Kamijo TSH-receptor antibody measurement in patients with various thyrotoxicosis and Hashimoto's thyroiditis: a comparison of two two-step assays, coated plate ELISA using porcine TSH-receptor and coated tube radioassay using human recombinant TSH-receptor. , 2003, Endocrine journal.

[7]  C. Chapman,et al.  Measurement of thyroid-stimulating hormone receptor autoantibodies by ELISA. , 1999, Clinical chemistry.

[8]  B. Smith,et al.  The interaction of TSH receptor autoantibodies with 125I-labelled TSH receptor. , 1999, The Journal of clinical endocrinology and metabolism.

[9]  K. Usadel,et al.  Second generation assay for thyrotropin receptor antibodies has superior diagnostic sensitivity for Graves' disease. , 1999, The Journal of clinical endocrinology and metabolism.

[10]  A. Weetman,et al.  The antibody response in human autoimmune thyroid disease. , 1997, Clinical science.

[11]  U. Feldt-Rasmussen,et al.  Analytical and clinical performance goals for testing autoantibodies to thyroperoxidase, thyroglobulin, and thyrotropin receptor. , 1996, Clinical chemistry.