[Dynamic contour tonometry].

Dynamic contour tonometry (DCT) is a new technology for noninvasive and direct measurement of intraocular pressure (IOP); its results are thought to be influenced less than those of other methods by structural characteristics of the eye. The curvature of the pressure sensing device is concave and only slightly flatter than that of the human cornea. The cornea adapts to the curvature of the transducer head, and the sensor in the centre of the adapted area measures the pressure on the other side of the cornea in the force-free range. Studies published so far suggest that DCT is less heavily dependent than applanation tonometry on the biomechanical properties of the cornea . A further advantage of DCT over other forms of tonometry is the capability of dynamic measurements over time. It is also possible to measure both the diastolic and the systolic IOD and determine the difference between the two, i.e. the ocular pulse amplitude (OPA). OPA is an indirect indicator of choroidal perfusion and reflects the condition of the arterial vascular system and the action of the heart. It could be important in the diagnosis and treatment of glaucoma.

[1]  M. Breve,et al.  Goldmann applanation tonometry after myopic photorefractive keratectomy. , 1998, Acta ophthalmologica Scandinavica.

[2]  J. Parel,et al.  Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. , 1993, Refractive & corneal surgery.

[3]  Y. Lachkar,et al.  Comparison of Dynamic Contour Tonometry With Goldman Applanation Tonometry Over a Wide Range of Central Corneal Thickness , 2005, Journal of glaucoma.

[4]  F. Grehn,et al.  Intraocular Pressure Measurement-Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry , 2005 .

[5]  G. Gamble,et al.  Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry , 2006, Eye.

[6]  R. Stamper,et al.  Dynamic contour tonometry: a comparative study on human cadaver eyes. , 2004, Archives of ophthalmology.

[7]  W. Argus,et al.  Ocular hypertension and central corneal thickness. , 1995, Ophthalmology.

[8]  D. Pye,et al.  Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo , 1999, Bulletin of mathematical biology.

[9]  N. Ehlers,et al.  APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS , 1975, Acta ophthalmologica.

[10]  T. Hikichi,et al.  Pulsatile ocular blood flow study: decreases in exudative age related macular degeneration , 2001, The British journal of ophthalmology.

[11]  D. Mojon,et al.  Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension , 2001, The British journal of ophthalmology.

[12]  C. Kaufmann,et al.  Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. , 2003, Investigative ophthalmology & visual science.

[13]  L. Kagemann,et al.  Intraocular Pressure and Photorefractive Keratectomy: A Comparison of Three Different Tonometers , 2001, Cornea.

[14]  A. Wirthlin,et al.  Dynamic Contour Tonometry for Post-LASIK Intraocular Pressure Measurements , 2004, Klinische Monatsblatter fur Augenheilkunde.

[15]  J. Funk,et al.  Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings , 2001, The British journal of ophthalmology.

[16]  G. Vrensen,et al.  The specific architecture of the anterior stroma accounts for maintenance of corneal curvature , 2001, The British journal of ophthalmology.

[17]  Ocular pulse amplitude after trabeculectomy , 2005, Graefe's Archive for Clinical and Experimental Ophthalmology.

[18]  G. Papastergiou,et al.  Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK , 2004, Journal of cataract and refractive surgery.

[19]  D. Henson,et al.  Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. , 1999, Ophthalmology.

[20]  M. B. Shields,et al.  Effect of Mild to Moderate Myopic Correction by Laser-Assisted In Situ Keratomileusis on Intraocular Pressure Measurements with Goldmann Applanation Tonometer, Tono-Pen, and Pneumatonometer , 2002, Journal of glaucoma.

[21]  T. Reinhard,et al.  [Impression and applanation tonometry in irregular corneas. Comparison with intraocular needle tonometry]. , 2000, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[22]  R. Stamper,et al.  Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states , 2005, Graefe's Archive for Clinical and Experimental Ophthalmology.

[23]  Shan C. Lin,et al.  Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. , 2005, Archives of ophthalmology.

[24]  H. Kanngiesser,et al.  Simulation of Dynamic Contour Tonometry Compared to an In Vitro Study Revealing Minimal Influence of Corneal Radius and Astigmatism , 2003 .

[25]  R. Stein,et al.  The effect of corneal thickness on applanation tonometry. , 1993, American journal of ophthalmology.

[26]  D. Garway-Heath,et al.  The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry , 2005, British Journal of Ophthalmology.

[27]  M. Podtetenev,et al.  Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis , 1998, Journal of cataract and refractive surgery.

[28]  N. Pfeiffer,et al.  Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry , 2004, BMC ophthalmology.

[29]  M. Twa,et al.  Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia. , 1999, Journal of cataract and refractive surgery.

[30]  E. Perkins,et al.  The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis. , 1985, The British journal of ophthalmology.

[31]  J. Beiser,et al.  Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). , 2001, Ophthalmology.

[32]  B. Emara,et al.  Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis , 1998, Journal of cataract and refractive surgery.

[33]  K. Mori,et al.  Evaluation of intraocular pressure change after laser in situ keratomileusis using the pressure phosphene tonometer , 2004, Journal of cataract and refractive surgery.

[34]  R. Stodtmeister,et al.  Applanation tonometry and correction according to corneal thickness. , 1998, Acta ophthalmologica Scandinavica.

[35]  A. Hofman,et al.  Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. , 1997, American journal of ophthalmology.

[36]  A. Serra,et al.  Tonometry After Laser in Situ Keratomileusis Treatment , 2001, Journal of glaucoma.

[37]  E. Perkins The ocular pulse. , 1981, Current eye research.

[38]  C. Kaufmann,et al.  Comparison of dynamic contour tonometry with goldmann applanation tonometry. , 2004, Investigative ophthalmology & visual science.

[39]  J. Jonas,et al.  Dynamic contour tonometry for intraocular pressure measurement. , 2005, American journal of ophthalmology.

[40]  F. Grus,et al.  Goldmann-Applanationstonometrie und dynamische Konturtonometrie , 2006, Der Ophthalmologe.

[41]  R. Stodtmeister [Comment on Velten IM, Bergua A, Horm FK, Junemann A, Korth M. "Central corneal thickness in normal probands, patients with ocular hypertension, normal pressure and open-angle glaucomas--a clinical study"]. , 2001, Klinische Monatsblatter fur Augenheilkunde.

[42]  J. Funk,et al.  Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study , 2005, Graefe's Archive for Clinical and Experimental Ophthalmology.

[43]  N. Çağıl,et al.  Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis , 2000, Journal of cataract and refractive surgery.

[44]  M. Langham,et al.  A rapid pneumatic applanation tonometer. Comparative findings and evaluation. , 1968, Archives of ophthalmology.

[45]  B. B. Fresco A new tonometer--the pressure phosphene tonometer: clinical comparison with Goldman tonometry. , 1998, Ophthalmology.