Heat Flux Distribution And Flame Shapes On The Inert Facade

Fire spread in high rise buildings from floor to floor occurs if flames emerge and extend on the facade of the building to cause ignition in the floor above the floor where flashover has developed. Even though considerable effort has been exerted to address this issue, proposed relations for heat fluxes on facade are incomplete and contradictory because the relevant physics have been poorly clarified. By systematically performing a series small scale experiments having various enclosure geometries, door-like openings and fire locations, the physics and new relations are underpinned for the emerging flames on inert facades in ventilation controlled (under-ventilated) fires at the floor of fire origin. To limit the variables and uncertainties, propane and methane gas burners create a controlled (theoretical) heat release rate at the source. Gas temperatures inside the enclosure and at the opening, heat fluxes on the facade wall, flame contours (by a Charge Coupled Device camera-CCD camera) and heat release rates (by oxygen calorimetry) inside and outside the enclosure have been measured. The gas temperatures inside the enclosure were uniform for aspect ratio (length to width) of the enclosure from one to one to three to one. Previous relations for the air inflow and heat release rate inside the enclosure were verified. The flames are highly radiative because soot can be formed at high temperatures inside the enclosure before the combustion gases and the unburned fuel exit the enclosure. The heat fluxes on an inert facade, both at the centreline and off-center above the opening, have been well correlated by identifying two length scales. One related to the effective area of the outflow ( 1 A ), and the other represented the length after which the flames turn from horizontal to vertical ( 3 A ). Finally, Correlation of the maximum flame width which is valid for the case having aspect ratio of the opening (width to height) between 0.375 and 2 was proposed in this paper. The results can be used for engineering calculations for real fires and for validation of new large eddy scale simulation models.

[1]  Michael A. Delichatsios,et al.  Heat fluxes and flame heights in façades from fires in enclosures of varying geometry , 2007 .

[2]  Benny Bøhm,et al.  The development of a small-scale fire compartment in order to determine thermal exposure inside and outside buildings , 1987 .

[3]  Haukur Ingason,et al.  Flame heat transfer in storage geometries , 1998 .

[4]  Michael A. DELlCHATSIOS Flame Heights in Turbulent Wall Fires with Significant Flame Radiation , 1984 .

[5]  M Delichatsios Effect of fuel sootiness on the heat fluxes to the walls in enclosure fires , 2005 .

[6]  Yuji Hasemi,et al.  Experimental Wall Flame Heat Transfer Correlations for the Analysis of Upward Wall Flame Spread , 1984 .

[7]  Jose L. Torero,et al.  Average centreline temperatures of a buoyant pool fire obtained by image processing of video recordings , 1995 .

[8]  T. J. Shields,et al.  Wall Heat Fluxes In Enclosure Fires , 2004 .

[9]  Thomas G. Cleary,et al.  Heat flux from flames to vertical surfaces , 1994 .

[10]  S E. Dillon,et al.  Analysis of the ISO 9705 Room/Corner Test: Simulations, Correlations and Heat Flux Measurements. | NIST , 1998 .

[11]  James G. Quintiere,et al.  Enclosure Fire Dynamics , 1999 .

[12]  S. Klopovic,et al.  Flames venting externally during full-scale flashover fires: two sample ventilation cases , 1998 .

[13]  Als Nscort Estimation of Rate of Heat Release by Means of Oxygen Consumption Measurements , 2003 .

[14]  M. Delichatsios,et al.  Flame Heights In Wall Fires: Effects Of Width, Confinement And Pyrolysis Length , 2000 .

[15]  G. M. Faeth,et al.  Turbulent wall fires , 1979 .