Comparative evaluation of the cerebral state index and the bispectral index during target-controlled infusion of propofol.

BACKGROUND Cerebral state index (CSI) has recently been introduced as an intra-operative monitor of anaesthetic depth. We compared the performance of the CSI to the bispectral index (BIS) in measuring depth of anaesthesia during target-controlled infusion (TCI) of propofol. METHODS Twenty Chinese patients undergoing general anaesthesia were recruited. CSI and BIS, and predicted effect-site concentration of propofol were recorded. The level of sedation was tested by Modified Observer's Assessment of Alertness/Sedation Scale (MOAAS) every 20 s during stepwise increase (TCI, 0.5 microg ml(-1)) of propofol. The loss of verbal contact (LVC) and loss of response (LOR) were defined by MOAAS values of 2-3 and less than 2, respectively. Baseline variability and the prediction probability (P(K)) were calculated for the BIS and CSI. The values of BIS(05) and CSI(05), BIS(50) and CSI(50), BIS(95) and CSI(95) were calculated at each end-point (LVC and LOR). RESULTS Baseline variability of CSI was more than that of BIS. Both CSI and BIS showed a high prediction probability for the steps awake vs LVC, awake vs LOR, and LVC vs LOR, and good correlations with MOAAS values. CONCLUSION Despite larger baseline variation, CSI performed as well as BIS in terms of P(K) values and correlations with step changes in sedation.

[1]  Peter S. Sebel,et al.  Bispectral Index Monitoring Allows Faster Emergence and Improved Recovery from Propofol, Alfentanil, and Nitrous Oxide Anesthesia , 1997 .

[2]  J. Jakobsson,et al.  Cerebral state index during anaesthetic induction: a comparative study with propofol or nitrous oxide , 2005, Acta anaesthesiologica Scandinavica.

[3]  D. Chernik,et al.  Validity and Reliability of the Observer's: Assessment of Alertness/Sedation Scale Study with Intravenous Midazolam , 1990, Journal of clinical psychopharmacology.

[4]  Steven L Shafer,et al.  Artifact Robustness, Inter- and Intraindividual Baseline Stability, and Rational EEG Parameter Selection , 2002, Anesthesiology.

[5]  G N Kenny,et al.  Development of the technology for ‘Diprifusor’ TCI systems , 1998, Anaesthesia.

[6]  M G Irwin,et al.  Relationship between bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points. , 2003, British journal of anaesthesia.

[7]  P. Sebel,et al.  Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia. BIS Utility Study Group. , 1997, Anesthesiology.

[8]  S. Kreuer,et al.  Narcotrend Monitoring Allows Faster Emergence and a Reduction of Drug Consumption in Propofol–Remifentanil Anesthesia , 2003, Anesthesiology.

[9]  J. Glen,et al.  The development of ‘Diprifusor’: a TCI system for propofol , 1998, Anaesthesia.

[10]  Warren D. Smith,et al.  Measuring the Performance of Anesthetic Depth Indicators , 1996, Anesthesiology.

[11]  P. Glass,et al.  Targeting effect compartment or central compartment concentration of propofol: what predicts loss of consciousness? , 1999, Anesthesiology.

[12]  E. Iannuzzi,et al.  Relationship between Bispectral Index, electroencephalographic state entropy and effect-site EC50 for propofol at different clinical endpoints. , 2005, British journal of anaesthesia.

[13]  Thomas Standl,et al.  Comparative Evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index® Monitor during Propofol–Remifentanil Anesthesia , 2004, Anesthesiology.

[14]  J. Drummond,et al.  Monitoring depth of anesthesia: with emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall. , 2000, Anesthesiology.

[15]  A. Zbinden,et al.  Different benefit of bispectal index (BIS™) in desflurane and propofol anesthesia , 2003, Acta anaesthesiologica Scandinavica.

[16]  N. Morton,et al.  Pharmacokinetic model driven infusion of propofol in children. , 1991, British journal of anaesthesia.

[17]  N. T. Smith,et al.  A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area. , 1996, Statistics in medicine.

[18]  I. Rampil A Primer for EEG Signal Processing in Anesthesia , 1998, Anesthesiology.

[19]  N. T. Smith,et al.  Performance of the ARX-derived Auditory Evoked Potential Index as an Indicator of Anesthetic Depth: A Comparison with Bispectral Index and Hemodynamic Measures during Propofol Administration , 2002, Anesthesiology.

[20]  G. Kenny,et al.  Propofol effective concentration 50 and its relationship to bispectral index , 2002, Anaesthesia.

[21]  J. Bruhn,et al.  Correlation of Approximate Entropy, Bispectral Index, and Spectral Edge Frequency 95 (SEF95) with Clinical Signs of “Anesthetic Depth” during Coadministration of Propofol and Remifentanil , 2003, Anesthesiology.