The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone.

Stereological parameters have been used as an approximation for the architecture of trabecular bone. Structural indices such as bone volume fraction (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), bone surface-to-volume ratio (BS/BV), degree of anisotropy (MIL1/MIL3), and connectivity density (-Euler/Vol) have been widely studied to investigate pathological conditions in bone. Due to its high resolution and nondestructiveness, microcomputed tomography (micro-CT) has been utilized to take precise three-dimensional (3D) images of trabecular microstructures. However, spatial limitations for applying micro-CT-based analyses to large specimens, such as whole vertebral bodies, require using larger scanning and reconstruction voxel sizes. In this study, combinations of three different scanning and reconstruction voxel size were used to represent best possible voxel size (21 microm; best in our scanner for the specimen size used) relative to other voxel sizes used in this study, commonly used intermediate voxel sizes (50 microm), and those applicable to scans of whole human vertebral bodies (110 microm) in order to examine the effect of scanning and reconstruction voxel size on stereological measures for human cancellous bone. The error in stereological parameters calculated using combinations of large voxel sizes compared to the gold standard (best possible case) ranged from 0.1% to 102%. The signed magnitude of the error in other cases relative to the gold standard was a function of either scanning or reconstruction voxel size or both (r2=0.55-0.95). For most of the structural indices, the results from analysis of images with larger voxel sizes were correlated with those from the gold standard (r2=0.55-0.99) except for Tb.N at 110/110 microm, MIL1/MIL3 at larger than 110 microm reconstruction voxel size, and -Euler/Vol at any combination of voxel sizes. Overall, it was observed that resampling a high resolution image at lower resolutions (corresponding to increasing reconstruction voxel size in this study) had different effects on the calculated parameters than scanning at the same low resolution (corresponding to increasing scanning voxel size in this study). Our results show that investigations of image resolution should include actual scans at the resolution of interest rather than simply coarsening of high-resolution images as is customarily done.

[1]  D. Altman,et al.  Calculating correlation coefficients with repeated observations: Part 2—correlation between subjects , 1995, BMJ.

[2]  S. Majumdar,et al.  Impact of spatial resolution on the prediction of trabecular architecture parameters. , 1998, Bone.

[3]  P. Rüegsegger,et al.  A microtomographic system for the nondestructive evaluation of bone architecture , 2006, Calcified Tissue International.

[4]  N. Fazzalari,et al.  Interrelationships Between Structural Parameters of Cancellous Bone Reveal Accelerated Structural Change at Low Bone Volume , 2003, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[5]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[6]  D. Fyhrie,et al.  Finite element calculated uniaxial apparent stiffness is a consistent predictor of uniaxial apparent strength in human vertebral cancellous bone tested with different boundary conditions. , 2001, Journal of biomechanics.

[7]  S. Goldstein,et al.  Variations in Three‐Dimensional Cancellous Bone Architecture of the Proximal Femur in Female Hip Fractures and in Controls , 2000, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[8]  M. Ito,et al.  Differences of three-dimensional trabecular microstructure in osteopenic rat models caused by ovariectomy and neurectomy. , 2002, Bone.

[9]  H. Gundersen,et al.  Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions. , 1993, Bone.

[10]  J. Kinney,et al.  The Relationship Between Three‐Dimensional Connectivity and the Elastic Properties of Trabecular Bone , 1998, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[11]  M. Kleerekoper,et al.  Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss. , 1983, The Journal of clinical investigation.

[12]  S. Goldstein,et al.  The direct examination of three‐dimensional bone architecture in vitro by computed tomography , 1989, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[13]  H. Weinans,et al.  A Three‐Dimensional Simulation of Age‐Related Remodeling in Trabecular Bone , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[14]  I. Hvid,et al.  Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone. , 2000, Bone.

[15]  S A Goldstein,et al.  The relationship between the structural and orthogonal compressive properties of trabecular bone. , 1994, Journal of biomechanics.

[16]  P. Rüegsegger,et al.  Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography. , 1998, Bone.

[17]  L. Gibson,et al.  Modeling the mechanical behavior of vertebral trabecular bone: effects of age-related changes in microstructure. , 1997, Bone.

[18]  P Rüegsegger,et al.  Introduction and evaluation of a gray-value voxel conversion technique. , 2001, Journal of biomechanics.

[19]  Yan Kang,et al.  A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data , 2003, IEEE Transactions on Medical Imaging.

[20]  P. Rüegsegger,et al.  Calibration of trabecular bone structure measurements of in vivo three-dimensional peripheral quantitative computed tomography with 28-microm-resolution microcomputed tomography. , 1999, Bone.

[21]  M. Hahn,et al.  High Spatial Resolution Imaging of Bone Mineral Using Computed Microtomography: Comparison with Microradiography and Undecalcified Histologic Sections , 1993, Investigative radiology.

[22]  M. Ito,et al.  Stage-dependent changes in trabecular bone turnover and osteogenic capacity of marrow cells during development of type II collagen-induced arthritis in mice. , 2002, Bone.

[23]  H. Weinans,et al.  Canine Cancellous Bone Microarchitecture after One Year of High-Dose Bisphosphonates , 2003, Calcified Tissue International.

[24]  I. Hvid,et al.  Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis. , 2003, The Journal of bone and joint surgery. British volume.

[25]  P Rüegsegger,et al.  Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions. , 1999, Journal of biomechanics.

[26]  D. Altman,et al.  Statistics notes: Calculating correlation coefficients with repeated observations: Part 1—correlation within subjects , 1995 .

[27]  C. Turner,et al.  Long‐Term Dosing of Arzoxifene Lowers Cholesterol, Reduces Bone Turnover, and Preserves Bone Quality in Ovariectomized Rats , 2002, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[28]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[29]  David P. Fyhrie,et al.  The impact of boundary conditions and mesh size on the accuracy of cancellous bone tissue modulus determination using large-scale finite-element modeling , 1999 .

[30]  A Odgaard,et al.  Three-dimensional methods for quantification of cancellous bone architecture. , 1997, Bone.

[31]  L. Claes,et al.  Glucocorticoid Treatment of Ovariectomized Sheep Affects Mineral Density, Structure, and Mechanical Properties of Cancellous Bone , 2003, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[32]  S. Goldstein,et al.  Finite‐element modeling of trabecular bone: Comparison with mechanical testing and determination of tissue modulus , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.