THE USE OF MIGRATING CORROSION INHIBITORS TO REPAIR MOTORWAYS' CONCRETE STRUCTURES CONTAMINATED BY CHLORIDES

The effectiveness of migrating corrosion inhibitors (MCIs) and repair mortars against rebar corrosion was studied in concrete specimens made by ordinary Portland cement with w/c ratio equal to 0.6 and containing 1 wt.% of chlorides. An alkanolamine-based inhibitor was tested in addition with a common mortar and two repair mortars. Electrochemical techniques, measurements of corrosion potential and electrochemical impedance spectroscopy (EIS) were used to determine the corrosion behaviour of the specimens when a cell containing a 3.5% NaCl solution was applied on the rehabilitation mortar. Mercury intrusion porosimetry (MIP) was also used for the characterisation of repair mortars' total porosity and a chemical analysis was made to determine the amount of chlorides penetrated in the mortar layers and in the concrete substrate. Results demonstrate that the simultaneous use of the alkanolamine-based inhibitor with a good barrier coating offers protection against rebar corrosion and allows rehabilitation of deteriorated concrete structures.

[1]  Kenneth C. Hover,et al.  Mercury porosimetry of hardened cement pastes , 1999 .

[2]  Anne B. Abell,et al.  Mercury Intrusion Porosimetry and Image Analysis of Cement-Based Materials. , 1999, Journal of colloid and interface science.

[3]  G. Batis,et al.  CORROSION PROTECTION INVESTIGATION OF REINFORCEMENT BY INORGANIC COATING IN THE PRESENCE OF ALKANOLAMINE-BASED INHIBITOR , 2003 .

[4]  Sidney Diamond,et al.  Mercury porosimetry: An inappropriate method for the measurement of pore size distributions in cement-based materials , 2000 .

[5]  E. Triki,et al.  The application of electrochemical impedance spectroscopy to determine the long-term effectiveness of corrosion inhibitors for steel in concrete , 2002 .

[6]  Bernhard Elsener,et al.  Migrating Corrosion Inhibitor Blend for Reinforced Concrete: Part 2— Inhibitor as Repair Strategy , 2000 .

[7]  P H Emmons,et al.  How to make today’s repairs durable for tomorrow — corrosion protection in concrete repair , 2000 .

[8]  G. Batis,et al.  Effects of migrating inhibitors on corrosion of reinforcing steel covered with repair mortar , 2003 .

[9]  Carmen Andrade,et al.  Corrosion rate monitoring in the laboratory and on-site , 1996 .

[10]  B. Elsener Macrocell corrosion of steel in concrete – implications for corrosion monitoring , 2002 .

[11]  Carolyn M. Hansson,et al.  Corrosion inhibitors in concrete—part I: the principles , 1998 .

[12]  H Böhni,et al.  Ink-bottle effect in mercury intrusion porosimetry of cement-based materials. , 2002, Journal of colloid and interface science.