Harmonic filters planning of system for specially connected transformers using PSO-NTVE method

This paper is used to investigate the harmonic filters planning of a power system with three-phase to two-phase specially connected transformers. A particle swarm optimization method with nonlinear time-varying evolution (PSO-NTVE) is employed in the planning of large-scale passive harmonic filters. The objective is to minimize the cost of the filter, the filters loss, the total harmonic distortion of currents and voltages at each bus simultaneously. The reactive power compensation and constraints of individual harmonics are also considered. Three design cases are compared to demonstrate the design results. The study results shows that the scheme type of three-phase to two-phase specially connected transformers have significant effects on the harmonic distribution. The phase B of VV connection scheme has reduced 3rd order harmonic distortion, the Scott and Le Blanc connection scheme batter than VV connection scheme for improved harmonic distortion, and the many typical passive filters structure batter than one typical filter. From the results of the illustrative examples, the feasibility of the PSO-NTVE to design an optimal passive harmonic filter is verified.

[1]  Anders Larsson Aktivitet: International Conference on Harmonics and Quality of Power , 2010 .

[2]  Fabrizio Giulio Luca Pilo,et al.  Voltage regulation on 25 kV AC railway systems by using thyristor switched capacitor , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[3]  Kun-Ping Lin,et al.  An advanced computer code for single-tuned harmonic filter design , 1997, 1997 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record.

[4]  Ward Jewell,et al.  Effects of harmonics on equipment , 1993 .

[5]  D. A. Gonzalez,et al.  Design of Filters to Reduce Harmonic Distortion in Industrial Power Systems , 1987, IEEE Transactions on Industry Applications.

[6]  Cristian Bovo,et al.  The use of genetic algorithms for the localization and the sizing of passive filters , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[7]  B. Bhargava Arc furnace flicker measurements and control , 1993 .

[8]  T. H. Chen,et al.  Network modelling of traction substation transformers for studying unbalance effects , 1995 .

[9]  Ying-Pin Chang,et al.  A PSO Method With Nonlinear Time-Varying Evolution for Optimal Design of Harmonic Filters , 2009, IEEE Transactions on Power Systems.

[10]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[11]  Tsai-Hsiang Chen Simplified models of electric railway substations for three-phase power-flow studies , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.