A rapid detection of neopterin based on a label-free and homogeneous FRET immunoassay system

Herein, we have developed a label-free and homogeneous fluorescence resonance energy transfer (FRET) immunoassay for the detection of neopterin (NPT), which is an early and valuable biochemical marker of cellular immunity. Owing to intrinsic fluorescence properties of antibody and NPT, anti-NPT antibody (anti-NPT) and analyte played roles as the respective donor and acceptor in the FRET immunoassay. As the concentration of NPT increases, the fluorescence intensity at ~350 nm decreases owing to the formation of increasing amounts of the anti-NPT/NPT complex in which FRET takes place. The assay system was found to display a high specificity and a low detection limit (0.14 ng mL-1) for NPT. A practical application of the FRET immunoassay system was demonstrated by its use in the detection of NPT in spiked human serum samples. The observations made in these efforts show that the homogeneous FRET immunoassay strategy, which requires a simple sample preparation procedure, serves as a powerful tool for the rapid and sensitive quantitative determination of NPT.

[1]  G. Hasçelik,et al.  The value of increased neopterin levels in reducing transfusion-transmitted virus infections: detection of a donation from a HBsAg positive chronic carrier by screening of neopterin in Turkish blood donors , 2005, Scandinavian journal of infectious diseases.

[2]  Min-Gon Kim,et al.  A label-free, direct and noncompetitive FRET immunoassay for ochratoxin A based on intrinsic fluorescence of an antigen and antibody complex. , 2011, Chemical communications.

[3]  Bo Bae Kim,et al.  Label-free homogeneous FRET immunoassay for the detection of mycotoxins that utilizes quenching of the intrinsic fluorescence of antibodies. , 2013, Biosensors & bioelectronics.

[4]  A. Shaw Serum C-reactive protein and neopterin concentrations in patients with viral or bacterial infection. , 1991, Journal of clinical pathology.

[5]  B. Cho,et al.  Neopterin, a marker of immune response, and 8-hydroxy-2'-deoxyguanosine, a marker of oxidative stress, correlate at high age as determined by automated simultaneous high-performance liquid chromatography analysis of human urine. , 2008, Analytical biochemistry.

[6]  N. Nakazawa,et al.  Radioimmunoassay for neopterin in body fluids and tissues. , 1984, Analytical biochemistry.

[7]  Min-Gon Kim,et al.  A label-free fluorescence immunoassay system for the sensitive detection of the mycotoxin, ochratoxin A. , 2012, Chemical communications.

[8]  T. Sugimoto,et al.  Polarization fluoroimmunoassay of biopterin and neopterin in human urine. , 1984, Clinica chimica acta; international journal of clinical chemistry.

[9]  E. Werner,et al.  Simultaneous determination of neopterin and creatinine in serum with solid-phase extraction and on-line elution liquid chromatography. , 1987, Clinical chemistry.

[10]  B. Melichar,et al.  Fluorimetric determination of the levels of urinary neopterin and serum thiobarbituric acid reactive substances in the nonagenarians. , 2003, Talanta.