Design of a Gait Training device for control of pelvic obliquity

This paper presents the design and testing of a novel device for the control of pelvic obliquity during gait. The device, called the Robotic Gait Rehabilitation (RGR) Trainer, consists of a single actuator system designed to target secondary gait deviations, such as hip-hiking, affecting the movement of the pelvis. Secondary gait deviations affecting the pelvis are generated in response to primary gait deviations (e.g. limited knee flexion during the swing phase) in stroke survivors and contribute to the overall asymmetrical gait pattern often observed in these patients. The proposed device generates a force field able to affect the obliquity of the pelvis (i.e. the rotation of the pelvis around the anteroposterior axis) by using an impedance controlled single linear actuator acting on a hip orthosis. Tests showed that the RGR Trainer is able to induce changes in pelvic obliquity trajectories (hip-hiking) in healthy subjects. These results suggest that the RGR Trainer is suitable to test the hypothesis that has motivated our efforts toward developing the system, namely that addressing both primary and secondary gait deviations during robotic-assisted gait training may help promote a physiologically-sound gait behavior more effectively than when only primary deviations are addressed.

[1]  Paolo Bonato,et al.  Robotically generated force fields for stroke patient pelvic obliquity gait rehabilitation , 2010, 2010 IEEE International Conference on Robotics and Automation.

[2]  Carolynn Patten,et al.  Reliability of gait performance tests in men and women with hemiparesis after stroke. , 2005, Journal of rehabilitation medicine.

[3]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2009, Circulation.

[4]  G. Morone,et al.  Who May Benefit From Robotic-Assisted Gait Training? , 2011, Neurorehabilitation and neural repair.

[5]  M. Mayer,et al.  Clinical neurokinesiology of spastic gait. , 2002, Bratislavske lekarske listy.

[6]  M. Molinari,et al.  Rehabilitation of gait after stroke: a review towards a top-down approach , 2011, Journal of NeuroEngineering and Rehabilitation.

[7]  S. Olney,et al.  Multivariate examination of data from gait analysis of persons with stroke. , 1998, Physical therapy.

[8]  V. Dietz,et al.  Locomotor activity in spinal man , 1994, The Lancet.

[9]  M. Morari,et al.  Adaptive robotic rehabilitation of locomotion: a clinical study in spinally injured individuals , 2003, Spinal Cord.

[10]  H. van der Kooij,et al.  Design of a compliantly actuated exo-skeleton for an impedance controlled gait trainer robot , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  J. Jeng,et al.  Effect of functional status on survival in patients with stroke: is independent ambulation a key determinant? , 2012, Archives of physical medicine and rehabilitation.

[12]  S.J. Harkema,et al.  A Robot and Control Algorithm That Can Synchronously Assist in Naturalistic Motion During Body-Weight-Supported Gait Training Following Neurologic Injury , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  Neville Hogan,et al.  Stable execution of contact tasks using impedance control , 1987, Proceedings. 1987 IEEE International Conference on Robotics and Automation.

[14]  Dale A. Lawrence,et al.  Impedance control stability properties in common implementations , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.