A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD.

PURPOSE The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. METHODS DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. RESULTS A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. CONCLUSIONS A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis.

[1]  E Samei,et al.  Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. , 1999, Radiology.

[2]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[3]  Patrik Sund,et al.  Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography , 2004, European Radiology.

[4]  Anders Tingberg,et al.  Nodule detection in digital chest radiography: introduction to the RADIUS chest trial. , 2005, Radiation protection dosimetry.

[5]  Anders Tingberg,et al.  Nodule detection in digital chest radiography: summary of the RADIUS chest trial. , 2005, Radiation protection dosimetry.

[6]  Santiago Martinez-Jimenez,et al.  Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. , 2008, Medical physics.

[7]  A. Flinck,et al.  Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. , 2008, Radiology.

[8]  John M. Sabol,et al.  A Monte Carlo estimation of effective dose in chest tomosynthesis. , 2009, Medical physics.

[9]  M Båth,et al.  Effect of clinical experience of chest tomosynthesis on detection of pulmonary nodules , 2009, Acta radiologica.

[10]  Emilio Quaia,et al.  The value of digital tomosynthesis in the diagnosis of suspected pulmonary lesions on chest radiography: analysis of diagnostic accuracy and confidence. , 2010, Academic radiology.

[11]  A. U. Sonawane,et al.  Estimation of skin entrance doses (SEDs) for common medical X-ray diagnostic examinations in India and proposed diagnostic reference levels (DRLs). , 2010, Radiation protection dosimetry.

[12]  Kyung Soo Lee,et al.  Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. , 2010, Radiology.

[13]  Anders Tingberg,et al.  X-ray tomosynthesis: a review of its use for breast and chest imaging. , 2010, Radiation protection dosimetry.

[14]  Magnus Båth,et al.  Simulation of dose reduction in tomosynthesis. , 2009, Medical physics.

[15]  Magnus Båth,et al.  Monte Carlo simulations of the dosimetry of chest tomosynthesis. , 2010, Radiation protection dosimetry.

[16]  Magnus Båth,et al.  Effective dose to patients from chest examinations with tomosynthesis. , 2010, Radiation protection dosimetry.

[17]  M Båth,et al.  Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital. , 2010, Radiation protection dosimetry.

[18]  Mats Geijer,et al.  Tomosynthesis in pulmonary cystic fibrosis with comparison to radiography and computed tomography: a pictorial review , 2011, Insights into Imaging.

[19]  Hiroaki Sugiura,et al.  Fast Scanning Tomosynthesis for the Detection of Pulmonary Nodules: Diagnostic Performance Compared With Chest Radiography, Using Multidetector-Row Computed Tomography as the Reference , 2011, Investigative radiology.

[20]  Jonas Ivarsson,et al.  Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria , 2011, Acta radiologica.

[21]  Emilio Quaia,et al.  Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography , 2012, European Radiology.

[22]  Kenji Ogawa,et al.  Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference , 2013, European Radiology.

[23]  Emilio Quaia,et al.  Digital tomosynthesis as a problem-solving imaging technique to confirm or exclude potential thoracic lesions based on chest X-ray radiography. , 2013, Academic radiology.

[24]  Mats Geijer,et al.  Conversion factors for estimation of effective dose in paediatric chest tomosynthesis. , 2013, Radiation protection dosimetry.

[25]  I. Vlahos Commentary on: Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease. , 2013, Clinical radiology.

[26]  K I Kim,et al.  Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease. , 2013, Clinical radiology.

[27]  Ehsan Samei,et al.  Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus. , 2014, Medical physics.

[28]  Magnus Båth,et al.  Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis , 2014, European Radiology.

[29]  Magnus Båth,et al.  A retrospective study of chest tomosynthesis as a tool for optimizing the use of computed tomography resources and reducing patient radiation exposure. , 2014, Academic radiology.

[30]  M. Cova,et al.  Diagnostic imaging costs before and after digital tomosynthesis implementation in patient management after detection of suspected thoracic lesions on chest radiography , 2014, Insights into Imaging.

[31]  Jenny Vikgren,et al.  Chest Tomosynthesis: Technical and Clinical Perspectives , 2014, Seminars in Respiratory and Critical Care Medicine.

[32]  Digital tomosynthesis of the chest: A review article , 2016 .