Noninvasive Doppler Determination of Cardiac Output in Man: Clinical Validation

A noninvasive technique for assessing cardiac output (CO) was evaluated by comparing it with thermodilution determinations in patients in the intensive care unit. The new method uses pulsed ultrasound to measure aortic diameter and continuous-wave Doppler ultrasound to obtain aortic blood velocity. An initial study evaluating just the velocity measurement showed that changes of the Doppler index of output (DI) correlated well with those of thermodilution cardiac output (TDCO). Linear regresson analysis yielded ADI = 0.87 ATDCO + 0.14 (r = 0.83, n = 95). Using a university research instrument these measurements were possible in 54 of 60 patients (90%). A second study using a prototype commercial device incorporated the diameter measurement. Ultrasonic cardiac output (UCO), calculated as the time integral of velocity multiplied by the aortic area, was compared to TDCO. The data, obtained from 45 of 53 patients (85%), are described by the linear regression UCO = 0.95TDCO + 0.38 (r = 0.94, n = 110) over a range of 2–11 I/min. Patients with aortic stenosis, aortic insufficiency or a prosthetic valve have been excluded from the second study due to conditions likely to violate the assumptions upon which the calculation of absolute cardiac output is based. These results indicate that accurate CO can be measured by noninvasive ultrasound in most patients. The technique may be useful for extended CO monitoring in acute care patients and for CO assessment in many other types of patients undergoing diagnostic studies and the rapeutic interventions.

[1]  C. Clark,et al.  Velocity distribution in aortic flow. , 1973, Cardiovascular research.

[2]  L. Huntsman,et al.  Estimation of Stroke Volume Changes by Ultrasonic Doppler , 1977, Circulation.

[3]  Abraham Guz,et al.  Left Ventricular Ejection in Conscious Dogs: I. Measurement and Significance of the Maximum Acceleration of Blood from the Left Ventricle , 1966 .

[4]  L. Light Non-injurious Ultrasonic Technique for observing Flow in the Human Aorta , 1969, Nature.

[5]  Y. Sohn,et al.  Accuracy of systolic time intervals in detecting abnormal left ventricular performance in coronary artery disease. , 1981, The American journal of cardiology.

[6]  P. Peronneau,et al.  Flow in the thoracic aorta. , 1979, Cardiovascular research.

[7]  G. Reeder Heart Disease: A Textbook of Cardiovascular Medicine , 1984 .

[8]  L. Hatle Noninvasive Assessment and Differentiatioih of Left Ventricular Outflow Obstruction with Doppler Ultrasound , 1981, Circulation.

[9]  D. Jewitt,et al.  Manual of Otolaryngology , 1969 .

[10]  N. Wood,et al.  Velocity patterns in the aorta. , 1971, Cardiovascular research.

[11]  G. Diamond,et al.  Correlative classification of clinical and hemodynamic function after acute myocardial infarction. , 1977, The American journal of cardiology.

[12]  A. Brubakk,et al.  Measurement of instantaneous blood-flow velocity in the human aorta using pulsed Doppler ultrasound. , 1982, Cardiovascular research.

[13]  H N Sabbah,et al.  Turbulent Blood Flow in the Ascending Aorta of Humans with Normal and Diseased Aortic Valves , 1976, Circulation research.

[14]  J. Greenfield,et al.  Relation Between Pressure and Diameter in the Ascending Aorta of Man , 1962, Circulation research.

[15]  E R Greene,et al.  Beat-by-beat stroke volume assessment by pulsed Doppler in upright and supine exercise. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.

[16]  A. Caprihan,et al.  Observer variability in serial noninvasive measurements of stroke index using pulsed Doppler flowmetry. , 1982, Biomedical sciences instrumentation.

[17]  R S Mackay,et al.  Non-invasive cardiac output measurement. , 1972, Microvascular research.

[18]  D. Nutter,et al.  Peak aortic flow and acceleration as indices of ventricular performance in the dog. , 1971, The Journal of laboratory and clinical medicine.

[19]  A. H. Reed,et al.  Prognostic significance of systolic time intervals after recovery from myocardial infarction. , 1981, The American journal of cardiology.

[20]  G. Motté,et al.  Evaluation of the elasticity and characteristic impedance of the ascending aorta in man. , 1978, Cardiovascular research.

[21]  J M Levett,et al.  Thermodilution cardiac output: a critical analysis and review of the literature. , 1979, The Journal of surgical research.

[22]  L. Huntsman,et al.  Trancutaneous determination of aortic blood-flow velocities in man. , 1975, American heart journal.

[23]  J. Shillingford The management of acute myocardial infarction. , 1971, Postgraduate medical journal.

[24]  B. Angelsen,et al.  Transcutaneous measurement of blood flow velocity in the human aorta. , 1976, Cardiovascular research.