Fast Timing in Medical Imaging

We report in this article on the Fast Timing in Medical Imaging workshop, (Valencia, 2 June 2022). The workshop gathered 104 attendees from all over the world, with representatives from the academic and industrial sectors. During three very dense days, nuclear medicine physicians, radiologists, oncologists, immunologists, and biologists have debated with physicists, engineers, technologists of different disciplines, as well as with medical imaging industry representatives to devise about the importance of improving the timing performance of a new generation of medical imaging instrumentation, with a special focus on positron emission tomography scanners toward the ultimate goal of 10-ps coincidence time resolution (CTR), allowing a millimeter 3-D spatial resolution on an event-to-event basis by time-of-flight (TOF) techniques. This article summarizes the most up-to-date developments on the roadmap toward the 10-ps time of flight challenge based on the contributions to this workshop.

[1]  C. Tsoumpas,et al.  Image Reconstruction Analysis for Positron Emission Tomography With Heterostructured Scintillators , 2022, IEEE Transactions on Radiation and Plasma Medical Sciences.

[2]  M. Defrise,et al.  The SNR of Positron Emission Data With Gaussian and Non-Gaussian Time-of-Flight Kernels, With Application to Prompt Photon Coincidence , 2022, IEEE Transactions on Medical Imaging.

[3]  B. Weissler,et al.  A Comprehensive Study on the Timing Limits of the TOFPET2 ASIC and on Approaches for Improvements , 2022, IEEE Transactions on Radiation and Plasma Medical Sciences.

[4]  M. C. Jiménez-Ramos,et al.  Characterization of a Compton camera based on the TOFPET2 ASIC , 2022, Radiation Physics and Chemistry.

[5]  Haewook Park,et al.  Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review , 2022, Biomedical Engineering Letters.

[6]  S. Korpar,et al.  Multipanel Limited Angle PET System With 50 ps FWHM Coincidence Time Resolution: A Simulation Study , 2022, IEEE Transactions on Radiation and Plasma Medical Sciences.

[7]  E. Auffray,et al.  Highly luminescent scintillating hetero-ligand MOF nanocrystals with engineered Stokes shift for photonic applications , 2022, Nature Communications.

[8]  S. Gundacker,et al.  Power-efficient high-frequency readout concepts of SiPMs for TOF-PET and HEP , 2022, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[9]  M. Paganoni,et al.  Advances in heterostructured scintillators: toward a new generation of detectors for TOF-PET , 2022, Physics in medicine and biology.

[10]  V. Rosso,et al.  A neural network-based algorithm for simultaneous event positioning and timestamping in monolithic scintillators , 2022, Physics in medicine and biology.

[11]  A. Mehranian,et al.  Deep learning–based time-of-flight (ToF) image enhancement of non-ToF PET scans , 2022, European Journal of Nuclear Medicine and Molecular Imaging.

[12]  J. Kopal,et al.  Ultrafast PWO scintillator for future high energy physics instrumentation , 2022, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[13]  R. Ota,et al.  Monolithic Integration of Metalens in Silicon Photomultiplier for Improved Photodetection Efficiency , 2022, Advanced Optical Materials.

[14]  S. Cherry,et al.  Time Resolution Studies of Thallium Based Cherenkov Semiconductors , 2022, Frontiers in Physics.

[15]  J. Benlloch,et al.  Metascintillators for Ultrafast Gamma Detectors: A Review of Current State and Future Perspectives , 2022, IEEE Transactions on Radiation and Plasma Medical Sciences.

[16]  J. Benlloch,et al.  Metascintillators: New Results for TOF-PET Applications , 2021, IEEE Transactions on Radiation and Plasma Medical Sciences.

[17]  E. Charbon,et al.  Sub-10 ps Minimum Ionizing Particle Detection With Geiger-Mode APDs , 2021, Frontiers in Physics.

[18]  E. Auffray,et al.  Timing performance of lead halide perovskite nanoscintillators embedded in a polystyrene matrix , 2022, Journal of Materials Chemistry C.

[19]  F. Kulzer,et al.  Perspective on the scintillating response of CdSe based nanoplatelets heterostructures , 2022, Materials Advances.

[20]  E. Auffray,et al.  Compositional engineering of multicomponent garnet scintillators: Towards an ultra-accelerated scintillation response , 2022, Materials Advances.

[21]  M. Korzhik,et al.  Transient optical absorption as a powerful tool for engineering of lead tungstate scintillators towards faster response , 2022, Journal of Materials Chemistry C.

[22]  E. Mihóková,et al.  Scintillation Response Enhancement in Nanocrystalline Lead Halide Perovskite Thin Films on Scintillating Wafers , 2021, Nanomaterials.

[23]  E. Stępień,et al.  Novel biomarker and drug delivery systems for theranostics – extracellular vesicles , 2021, Bio Algorithms Med Syst..

[24]  E. Auffray,et al.  Ultraviolet cross-luminescence in ternary chlorides of alkali and alkaline-earth metals , 2021, Optical Materials: X.

[25]  J. Benlloch,et al.  Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals. , 2021, Medical physics.

[26]  A. Vaitkevičius,et al.  Influence of matrix composition and its fluctuations on excitation relaxation and emission spectrum of Ce ions in (Gd Y1-)3Al2Ga3O12:Ce scintillators , 2021, Journal of Luminescence.

[27]  R. Ballabriga,et al.  FastIC: A Highly Configurable ASIC for Fast Timing Applications , 2021, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[28]  K. Swientek,et al.  Results with the TOFHIR2X Revision of the Front-end ASIC of the CMS MTD Barrel Timing Layer , 2021, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[29]  J. Benlloch,et al.  Evaluation of Crystal Arrays for Accurate Positioning and Timing PET Detectors , 2021, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[30]  S. Cherry,et al.  Ultrafast timing enables reconstruction-free positron emission imaging , 2021, Nature Photonics.

[31]  Roger Lecomte,et al.  TOF Benefits and Trade-offs on Image Contrast-to-Noise Ratio Performance for a Small Animal PET Scanner , 2021, IEEE Transactions on Radiation and Plasma Medical Sciences.

[32]  E. Auffray,et al.  A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET , 2021, Physics in medicine and biology.

[33]  A. Vedda,et al.  Understanding Thermal and A‐Thermal Trapping Processes in Lead Halide Perovskites Towards Effective Radiation Detection Schemes , 2021, Advanced Functional Materials.

[34]  B. Hiesmayr,et al.  Simulating NEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators , 2021, Physics in medicine and biology.

[35]  R. Ota,et al.  40 × 40 Metalens Array for Improved Silicon Photomultiplier Performance , 2021 .

[36]  Davis,et al.  Direct positron emission imaging: ultra-fast timing enables reconstruction-free imaging , 2021, 2105.05805.

[37]  R. Fontaine,et al.  Comparative Study of Image Quality in Time-Correlated Single-Photon Counting Computed Tomography , 2021, IEEE Transactions on Radiation and Plasma Medical Sciences.

[38]  E. Auffray,et al.  Vacuum ultraviolet silicon photomultipliers applied to BaF2 cross-luminescence detection for high-rate ultrafast timing applications , 2021, Physics in medicine and biology.

[39]  Jun Yeon Won,et al.  Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system , 2021, Physics in medicine and biology.

[40]  A. Gola,et al.  Design considerations for a new generation of SiPMs with unprecedented timing resolution , 2021, Journal of Instrumentation.

[41]  R. Coffee,et al.  Ionizing photon interactions modulate the optical properties of crystals with femtosecond scale temporal resolution , 2021, Physics in medicine and biology.

[42]  C. Morel,et al.  A time-of-flight-based reconstruction for real-time prompt-gamma imaging in proton therapy , 2020, Physics in medicine and biology.

[43]  J. Dussault,et al.  Improvement of Spatial Resolution With Iterative PET Reconstruction Using Ultrafast TOF , 2020, IEEE Transactions on Radiation and Plasma Medical Sciences.

[44]  E. Auffray,et al.  TOF-PET Image Reconstruction With Multiple Timing Kernels Applied on Cherenkov Radiation in BGO , 2020, IEEE Transactions on Radiation and Plasma Medical Sciences.

[45]  F. Kulzer,et al.  Perspectives for CdSe/CdS Spherical Quantum Wells as Rapid-Response Nano-Scintillators , 2021, Nanoscale.

[46]  M. Korzhik,et al.  Role of inter- and intraconfigurational transitions of Pr3+ ion in nonequilibrium carrier relaxation in garnet-type scintillators , 2021 .

[47]  M. Paganoni,et al.  CMOS-compatible all-dielectric metalens for improving pixel photodetector arrays , 2020 .

[48]  Ali Hossain Khan,et al.  Colloidal Synthesis of Laterally Confined Blue-Emitting 3.5 Monolayer CdSe Nanoplatelets , 2020, Chemistry of materials : a publication of the American Chemical Society.

[49]  E. Stępień,et al.  Prospects and Clinical Perspectives of Total-Body PET Imaging Using Plastic Scintillators. , 2020, PET clinics.

[50]  S. Omelkov,et al.  Ultrafast Radiative Relaxation Processes in Multication Cross-Luminescence Materials , 2020, IEEE Transactions on Nuclear Science.

[51]  Y. Bercier,et al.  From a PMT-based to a SiPM-based PET system: a study to define matched acquisition/reconstruction parameters and NEMA performance of the Biograph Vision 450 , 2020, EJNMMI Physics.

[52]  Katia Parodi,et al.  Roadmap toward the 10 ps time-of-flight PET challenge , 2020, Physics in medicine and biology.

[53]  E. Auffray,et al.  Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction , 2020, Physics in medicine and biology.

[54]  R. Fontaine,et al.  Time-of-flight computed tomography - proof of principle , 2020, Physics in medicine and biology.

[55]  Bjoern Weissler,et al.  Investigation of the Power Consumption of the PETsys TOFPET2 ASIC , 2019, IEEE Transactions on Radiation and Plasma Medical Sciences.

[56]  P. Lecoq,et al.  On the use of CdSe scintillating nanoplatelets as time taggers for high-energy gamma detection , 2019, npj 2D Materials and Applications.

[57]  Paul Lecoq,et al.  Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept , 2019, Physics in medicine and biology.

[58]  S. Cherry,et al.  First Cerenkov charge-induction (CCI) TlBr detector for TOF-PET and proton range verification , 2019, Physics in medicine and biology.

[59]  R. Zhu,et al.  Development of Yttrium-Doped BaF2 Crystals for Future HEP Experiments , 2019, IEEE Transactions on Nuclear Science.

[60]  M. Korzhik,et al.  Improvement of the Time Resolution of Radiation Detectors Based on Gd3Al2Ga3O12 Scintillators With SiPM Readout , 2019, IEEE Transactions on Nuclear Science.

[61]  S. Cherry,et al.  Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET , 2019, Physics in medicine and biology.

[62]  C. Leong,et al.  Experimental characterization of the TOFPET2 ASIC , 2019, Journal of Instrumentation.

[63]  Marco Paganoni,et al.  High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET , 2019, Physics in medicine and biology.

[64]  Pengcheng Hu,et al.  First Human Imaging Studies with the EXPLORER Total-Body PET Scanner* , 2019, The Journal of Nuclear Medicine.

[65]  J. Oswald,et al.  Advancement toward ultra-thick and bright InGaN/GaN structures with a high number of QWs , 2019, CrystEngComm.

[66]  Martin Nikl,et al.  On the structure, synthesis, and characterization of ultrafast blue-emitting CsPbBr3 nanoplatelets , 2019, APL Materials.

[67]  Nicola Zorzi,et al.  NUV-Sensitive Silicon Photomultiplier Technologies Developed at Fondazione Bruno Kessler , 2019, Sensors.

[68]  C. Levin,et al.  Improved single photon time resolution for analog SiPMs with front end readout that reduces influence of electronic noise , 2018, Physics in medicine and biology.

[69]  Mirko Prato,et al.  Chloride-Induced Thickness Control in CdSe Nanoplatelets , 2018, Nano letters.

[70]  C. Levin,et al.  Evaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution , 2018, Physics in medicine and biology.

[71]  P. Lecoq,et al.  Precise rise and decay time measurements of inorganic scintillators by means of X-ray and 511 keV excitation , 2018 .

[72]  O. Ratib,et al.  Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project , 2018, 1802.01319.

[73]  P. Lecoq,et al.  Pushing the Limits in Time-of-Flight PET Imaging , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.

[74]  M. V. Nemallapudi,et al.  Single photon time resolution of state of the art SiPMs , 2016 .

[75]  E. Auffray,et al.  Effect of Mg2+ ions co-doping on timing performance and radiation tolerance of Cerium doped Gd3Al2Ga3O12 crystals , 2016 .

[76]  Paul Lecoq,et al.  Development of new scintillators for medical applications , 2016 .

[77]  Claudia Biermann,et al.  Mathematical Methods Of Statistics , 2016 .

[78]  A. Yoshikawa,et al.  Recent R&D Trends in Inorganic Single‐Crystal Scintillator Materials for Radiation Detection , 2015 .

[79]  Shunsuke Kurosawa,et al.  Defect Engineering in Ce-Doped Aluminum Garnet Single Crystal Scintillators , 2014 .

[80]  Paul Lecoq,et al.  Can Transient Phenomena Help Improving Time Resolution in Scintillators? , 2014, IEEE Transactions on Nuclear Science.

[81]  P. Dorenbos,et al.  Evidence and Consequences of Ce $^{4+}$ in LYSO:Ce,Ca and LYSO:Ce,Mg Single Crystals for Medical Imaging Applications , 2013, IEEE Transactions on Nuclear Science.

[82]  M. Paganoni,et al.  A Comprehensive & Systematic Study of Coincidence Time Resolution and Light Yield Using Scintillators of Different Size and Wrapping , 2011, IEEE Transactions on Nuclear Science.

[83]  C. Piemonte,et al.  Analog Circuit for Timing Measurements With Large Area SiPMs Coupled to LYSO Crystals , 2011, IEEE Transactions on Nuclear Science.

[84]  M. Brik,et al.  Ab Initio Studies of the Structural, Electronic, and Optical Properties of K2SiF6 Single Crystals at Ambient and Elevated Hydrostatic Pressure , 2012 .

[85]  M. Korzhik,et al.  Lead tungstate scintillation material , 2002 .

[86]  S. Baccaro,et al.  The doping of PbWO4 in shaping its scintillator characteristics , 2001 .

[87]  M. Martini,et al.  Modification of PbWO4 scintillator characteristics by doping , 2001 .

[88]  H H Barrett,et al.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[89]  P. Rodnyi,et al.  Radiative core-valence transitions in barium-based fluorides , 1991 .

[90]  T. Budinger Time-of-flight positron emission tomography: status relative to conventional PET. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[91]  Nizar A. Mullani,et al.  DESIGN OF TOFPET: A HIGH RESOLUTION TIME-OF-FLIGHT POSITRON CAMERA. , 1982 .

[92]  T. Tomitani Image Reconstruction and Noise Evaluation in Photon Time-of-Flight Assisted Positron Emission Tomography , 1981, IEEE Transactions on Nuclear Science.

[93]  D L Snyder,et al.  Photon Time‐of-Flight‐Assisted Positron Emission Tomography , 1981, Journal of computer assisted tomography.

[94]  Victor J. Sank,et al.  POTENTIAL ADVANTAGES OF A CESIUM FLUORIDE SCINTILLATOR FOR A TIME‐OF‐FLIGHT POSITRON CAMERA , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[95]  P. Hohenberg,et al.  Inhomogeneous Electron Gas , 1964 .