Soft-X-ray CCD imagers for AXAF

We describe the key features and performance data of a 1024/spl times/1026-pixel frame-transfer imager for use as a soft-X-ray detector on the NASA X-ray observatory Advanced X-ray Astrophysics Facility (AXAF). The four-port device features a floating-diffusion output circuit with a responsivity of 20 /spl mu/V/e/sup -/ and noise of about 2 e/sup -/ at a 100-kHz data rate. Techniques for achieving the low sense-node capacitance of 5 fF are described. The CCD is fabricated on high-resistivity p-type silicon for deep depletion and includes narrow potential troughs for transfer inefficiencies of around 10/sup -7/. To achieve good sensitivity at energies below 1 keV, we have developed a back-illumination process that features low recombination losses at the back surface and has produced quantum efficiencies of about 0.7 at 277 eV (carbon K/spl alpha/).

[1]  G. D. Watkins,et al.  Defects in Irradiated Silicon: Electron Paramagnetic Resonance and Electron-Nuclear Double Resonance of the Si-E Center , 1964 .

[2]  Barry E. Burke,et al.  Fano-Noise-Limited CCDs , 1988, Optics & Photonics.

[3]  George R. Ricker,et al.  Absolute measurement of oxygen edge structure in the quantum efficiency of X-ray CCDs , 1996 .

[4]  Barry E. Burke,et al.  CCD soft x-ray imagers for ASCA and AXAF , 1993, Optics & Photonics.

[5]  James R. Janesick,et al.  Radiation damage in scientific charge-coupled devices , 1989 .

[6]  Michael J. Pivovaroff,et al.  X-ray CCD calibration for the AXAF CCD Imaging Spectrometer , 1996, Optics & Photonics.

[7]  C. Canali,et al.  Measurements of the Average Energy Per Electron-Hole Pair Generation in Silicon between 5-320°K , 1972 .

[8]  Barry E. Burke,et al.  High-performance visible-UV CCD imagers for space-based applications , 1992, Defense, Security, and Sensing.

[9]  Barry E. Burke,et al.  An abuttable CCD imager for visible and X-ray focal plane arrays , 1991 .

[10]  James R. Janesick,et al.  Notch and large-area CCD imagers , 1991, Medical Imaging.

[11]  Michael J. Pivovaroff,et al.  Flight x-ray CCD selection for the AXAF CCD Imaging Spectrometer , 1996, Optics & Photonics.

[12]  Barry E. Burke,et al.  CCD soft X-ray imaging spectrometer for the ASCA satellite , 1994 .

[13]  H. Ito,et al.  A 100 MHz data-rate, 5000-element CCD linear image sensor with reset pulse level adjustment circuit , 1992, 1992 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[14]  Martin C. Weisskopf,et al.  Advanced X-ray Astrophysics Facility (AXAF): an overview , 1995, Optics & Photonics.

[15]  Barry E. Burke,et al.  Fabrication of large-area CCD detectors on high-purity, float-zone silicon , 1996 .