Three-dimensional multi bioluminescent sources reconstruction based on adaptive finite element method

Among many optical molecular imaging modalities, bioluminescence imaging (BLI) has more and more wide application in tumor detection and evaluation of pharmacodynamics, toxicity, pharmacokinetics because of its noninvasive molecular and cellular level detection ability, high sensitivity and low cost in comparison with other imaging technologies. However, BLI can not present the accurate location and intensity of the inner bioluminescence sources such as in the bone, liver or lung etc. Bioluminescent tomography (BLT) shows its advantage in determining the bioluminescence source distribution inside a small animal or phantom. Considering the deficiency of two-dimensional imaging modality, we developed three-dimensional tomography to reconstruct the information of the bioluminescence source distribution in transgenic mOC-Luc mice bone with the boundary measured data. In this paper, to study the osteocalcin (OC) accumulation in transgenic mOC-Luc mice bone, a BLT reconstruction method based on multilevel adaptive finite element (FEM) algorithm was used for localizing and quantifying multi bioluminescence sources. Optical and anatomical information of the tissues are incorporated as a priori knowledge in this method, which can reduce the ill-posedness of BLT. The data was acquired by the dual modality BLT and Micro CT prototype system that was developed by us. Through temperature control and absolute intensity calibration, a relative accurate intensity can be calculated. The location of the OC accumulation was reconstructed, which was coherent with the principle of bone differentiation. This result also was testified by ex vivo experiment in the black 96-plate well using the BLI system and the chemiluminescence apparatus.

[1]  Wenxiang Cong,et al.  A born-type approximation method for bioluminescence tomography. , 2006, Medical physics.

[2]  Xin Yang,et al.  Dual-Modality Monitoring of Tumor Response to Cyclophosphamide Therapy in Mice with Bioluminescence Imaging and Small-Animal Positron Emission Tomography , 2011, Molecular imaging.

[3]  Jie Tian,et al.  A multilevel adaptive finite element algorithm for bioluminescence tomography. , 2006, Optics express.

[4]  Geoffrey McLennan,et al.  Practical reconstruction method for bioluminescence tomography. , 2005, Optics express.

[5]  Vasilis Ntziachristos,et al.  Shedding light onto live molecular targets , 2003, Nature Medicine.

[6]  Jie Tian,et al.  Fast cone-beam CT image reconstruction using GPU hardware , 2008 .

[7]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[8]  Singiresu S. Rao The finite element method in engineering , 1982 .

[9]  Shan Zhao,et al.  Temperature-modulated bioluminescence tomography. , 2006, Optics express.

[10]  Yasuyoshi Watanabe,et al.  [Molecular imaging for drug development]. , 2007, Brain and nerve = Shinkei kenkyu no shinpo.

[11]  E. Zerhouni,et al.  Medicine. The NIH Roadmap. , 2003, Science.

[12]  Ralph Weissleder,et al.  Molecular imaging in the clinical arena. , 2005, JAMA.

[13]  A. Chatziioannou,et al.  Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study , 2005, Physics in medicine and biology.

[14]  R. Weissleder,et al.  Imaging in the era of molecular oncology , 2008, Nature.