A framework for continuous target tracking during MR-guided high intensity focused ultrasound thermal ablations in the abdomen

BackgroundDuring lengthy magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU) thermal ablations in abdominal organs, the therapeutic work-flow is frequently hampered by various types of physiological motion occurring at different time-scales. If left un-addressed this can lead to an incomplete therapy and/or to tissue damage of organs-at-risk. While previous studies focus on correction schemes for displacements occurring at a particular time-scale within the work-flow of an MRg-HIFU therapy, in the current work we propose a motion correction strategy encompassing the entire work-flow.MethodsThe proposed motion compensation framework consists of several linked components, each being adapted to motion occurring at a particular time-scale. While respiration was addressed through a fast correction scheme, long term organ drifts were compensated using a strategy operating on time-scales of several minutes. The framework relies on a periodic examination of the treated area via MR scans which are then registered to a reference scan acquired at the beginning of the therapy. The resulting displacements were used for both on-the-fly re-optimization of the interventional plan and to ensure the spatial fidelity between the different steps of the therapeutic work-flow. The approach was validated in three complementary studies: an experiment conducted on a phantom undergoing a known motion pattern, a study performed on the abdomen of 10 healthy volunteers and during 3 in-vivo MRg-HIFU ablations on porcine liver.ResultsResults have shown that, during lengthy MRg-HIFU thermal therapies, the human liver and kidney can manifest displacements that exceed acceptable therapeutic margins. Also, it was demonstrated that the proposed framework is capable of providing motion estimates with sub-voxel precision and accuracy. Finally, the 3 successful animal studies demonstrate the compatibility of the proposed approach with the work-flow of an MRg-HIFU intervention under clinical conditions.ConclusionsIn the current study we proposed an image-based motion compensation framework dedicated to MRg-HIFU thermal ablations in the abdomen, providing the possibility to re-optimize the therapy plan on-the-fly with the patient on the interventional table. Moreover, we have demonstrated that even under clinical conditions, the proposed approach is fully capable of continuously ensuring the spatial fidelity between the different phases of the therapeutic work-flow.

[1]  Bruno Quesson,et al.  Real‐time geometric distortion correction for interventional imaging with echo‐planar imaging (EPI) , 2009, Magnetic resonance in medicine.

[2]  F A Jolesz,et al.  A clinical, noninvasive, MR imaging-monitored ultrasound surgery method. , 1996, Radiographics : a review publication of the Radiological Society of North America, Inc.

[3]  L. Verhey,et al.  Immobilizing and Positioning Patients for Radiotherapy. , 1995, Seminars in radiation oncology.

[4]  K Hynynen,et al.  The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery. , 1994, The Journal of the Acoustical Society of America.

[5]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[6]  P. Batchelor,et al.  International Society for Magnetic Resonance in Medicine , 1997 .

[7]  Gábor Székely,et al.  Systematic errors in respiratory gating due to intrafraction deformations of the liver. , 2007, Medical physics.

[8]  M. Goitein Organ and tumor motion: an overview. , 2004, Seminars in radiation oncology.

[9]  M. Housset,et al.  Adaptive partial-boost stereotactic radiation therapy for muscle-invasive carcinoma of the urinary bladder , 2012 .

[10]  Kari Tanderup,et al.  Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy , 2008, Acta oncologica.

[11]  Sukru Mehmet Erturk,et al.  Functional Monitoring of Small Bowel Motility : Comparison of Spasmolysis Induced by Glucagon or Buscopan , 2008 .

[12]  Kim Butts Pauly,et al.  MR thermometry , 2008, Journal of magnetic resonance imaging : JMRI.

[13]  Paul R. Stauffer,et al.  Physics of Thermal Therapy: Fundamentals and Clinical Applications , 2013 .

[14]  Erlend Fagertun Hofstad,et al.  Validation of a non-rigid registration method for motion compensation in 4D ultrasound of the liver , 2013, 2013 IEEE 10th International Symposium on Biomedical Imaging.

[15]  Jean-Michel Morel,et al.  A Review of Image Denoising Algorithms, with a New One , 2005, Multiscale Model. Simul..

[16]  Ferenc A. Jolesz,et al.  MR‐Guided Focused Ultrasound Surgery , 1992, Journal of computer assisted tomography.

[17]  Sébastien Roujol,et al.  Real‐time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues , 2010, Magnetic resonance in medicine.

[18]  V.R.S Mani,et al.  Survey of Medical Image Registration , 2013 .

[19]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[20]  Juan M. Santos,et al.  Respiration based steering for high intensity focused ultrasound liver ablation , 2014, Magnetic resonance in medicine.

[21]  F V Gleeson,et al.  The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population , 2005, British Journal of Cancer.

[22]  P. Steerenberg,et al.  Targeting pathophysiological rhythms: prednisone chronotherapy shows sustained efficacy in rheumatoid arthritis. , 2010, Annals of the rheumatic diseases.

[23]  Suguru Dobashi,et al.  Evaluation of various deformable image registration algorithms for thoracic images , 2013, Journal of radiation research.

[24]  Jan-Jakob Sonke,et al.  Inter- and intrafraction variability in liver position in non-breath-hold stereotactic body radiotherapy. , 2009, International journal of radiation oncology, biology, physics.

[25]  R. McKinstry,et al.  Principles and applications of echo-planar imaging: a review for the general radiologist. , 2001, Radiographics : a review publication of the Radiological Society of North America, Inc.

[26]  R. Castillo,et al.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets , 2009, Physics in medicine and biology.

[27]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[28]  Yufeng Zhou,et al.  High intensity focused ultrasound in clinical tumor ablation. , 2011, World journal of clinical oncology.

[29]  Lorena Petrusca,et al.  Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo , 2012, Physics in medicine and biology.

[30]  M. V. van Herk,et al.  The influence of a dietary protocol on cone beam CT-guided radiotherapy for prostate cancer patients. , 2008, International journal of radiation oncology, biology, physics.

[31]  Kevin Cleary,et al.  Technologies for guidance of radiofrequency ablation in the multimodality interventional suite of the future. , 2007, Journal of vascular and interventional radiology : JVIR.

[32]  K. Brock Results of a multi-institution deformable registration accuracy study (MIDRAS). , 2010, International journal of radiation oncology, biology, physics.

[33]  R Miralbell,et al.  Radiotherapy of bladder cancer: relevance of bladder volume changes in planning boost treatment. , 1998, International journal of radiation oncology, biology, physics.

[34]  Cornel Zachiu,et al.  A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept. , 2015, Medical physics.

[35]  Philippe C. Cattin,et al.  3D Organ Motion Prediction for MR-Guided High Intensity Focused Ultrasound , 2011, MICCAI.

[36]  Patrick A Kupelian,et al.  Observations on real-time prostate gland motion using electromagnetic tracking. , 2008, International journal of radiation oncology, biology, physics.

[37]  Emad S. Ebbini,et al.  Real-Time 2-D Temperature Imaging Using Ultrasound , 2010, IEEE Transactions on Biomedical Engineering.

[38]  J. Kennedy High-intensity focused ultrasound in the treatment of solid tumours , 2005, Nature Reviews Cancer.

[39]  Michael Brady,et al.  MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration , 2012, Medical Image Anal..

[40]  D. Sahani,et al.  Current Status of Imaging and Emerging Techniques to Evaluate Liver Metastases From Colorectal Carcinoma , 2014, Annals of surgery.

[41]  B. Sanghera,et al.  The effects of N-butylscopolamine on bowel uptake: an 18F-FDG PET study , 2008, Nuclear medicine communications.

[42]  B Denis de Senneville,et al.  An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs , 2015, Physics in medicine and biology.

[43]  Kullervo Hynynen,et al.  Focused ultrasound surgery in oncology: overview and principles. , 2011, Radiology.

[44]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[45]  D. Dupuy,et al.  Thermal ablation of tumours: biological mechanisms and advances in therapy , 2014, Nature Reviews Cancer.

[46]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[47]  K. Steinke,et al.  Percutaneous CT-guided thermal ablation as salvage therapy for recurrent non-small cell lung cancer after external beam radiotherapy: A retrospective study , 2016, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[48]  Balraj Naren,et al.  Medical Image Registration , 2022 .

[49]  F. Gleeson,et al.  High-intensity focused ultrasound for the treatment of liver tumours. , 2004, Ultrasonics.

[50]  R. Salomir,et al.  Management of Respiratory Motion in Extracorporeal High-Intensity Focused Ultrasound Treatment in Upper Abdominal Organs: Current Status and Perspectives , 2013, CardioVascular and Interventional Radiology.