Fast axial scanning for 2-photon microscopy using liquid lens technology

Scanning microscopy methods require movement of the focus in Z coordinates to produce an image of a 3-dimensional volume. In a typical imaging system, the optical setup is kept fixed and either the sample or the objective is translated with a mechanical stage driven by a stepper motor or a piezoelectric element. Mechanical Z scanning is precise, but its slow response and vulnerability to mechanical vibrations and stress make it disadvantageous to image dynamic, time-varying samples such as live cell structures. An alternative method less susceptible to these problems is to change the focal plane using conjugate optics. Deformable mirrors, acousto-optics, and electrically tunable lenses have been experimented with to achieve this goal and have attained very fast and precise Z-scanning without physically moving the sample. Here, we present the use of a liquid lens for fast axial scanning. Liquid lenses have a long functional life, high degree of phase shift, and low sensitivity to mechanical stress. They work on the principle of refraction at a liquid-liquid interface. At the boundary of a polar and an apolar liquid a spherical surface is formed whose curvature can be controlled by adjusting its relative wettability using electro-wetting. We characterize the effects of the lens on attainable Z displacement, beam spectral characteristics, and pulse duration as compared with mechanical scanning.

[1]  Karel Svoboda,et al.  ScanImage: Flexible software for operating laser scanning microscopes , 2003, Biomedical engineering online.

[2]  Rodrigo Cuenca,et al.  Optical axial scanning in confocal microscopy using an electrically tunable lens. , 2014, Biomedical optics express.

[3]  Charles P. Lin,et al.  Deep tissue single cell MSC ablation using a fiber laser source to evaluate therapeutic potential in osteogenesis imperfecta , 2016, SPIE BiOS.

[4]  R. Silver,et al.  A compact Acousto-Optic Lens for 2D and 3D femtosecond based 2-photon microscopy. , 2010, Optics express.

[5]  B. Berge,et al.  Variable focal lens controlled by an external voltage: An application of electrowetting , 2000 .

[6]  I. Alex Vitkin,et al.  Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror , 2004 .

[7]  F. Helmchen,et al.  Imaging cellular network dynamics in three dimensions using fast 3D laser scanning , 2007, Nature Methods.

[8]  Masatoshi Ishikawa,et al.  Variable-focus lens with 1-kHz bandwidth. , 2004, Optics express.

[9]  K. Fujita [Two-photon laser scanning fluorescence microscopy]. , 2007, Tanpakushitsu kakusan koso. Protein, nucleic acid, enzyme.

[10]  B. Hendriks,et al.  Electrowetting-Based Variable-Focus Lens for Miniature Systems , 2005 .

[11]  John W Sedat,et al.  Modelling the application of adaptive optics to wide‐field microscope live imaging , 2007, Journal of microscopy.

[12]  Benjamin F. Grewe,et al.  Fast two-layer two-photon imaging of neuronal cell populations using an electrically tunable lens , 2011, Biomedical optics express.

[13]  Atsushi Miyawaki,et al.  ScaleS: an optical clearing palette for biological imaging , 2015, Nature Neuroscience.

[14]  Charles P. Lin,et al.  Femtosecond laser bone ablation with a high repetition rate fiber laser source. , 2015, Biomedical optics express.

[15]  Christian Chunzi Archer-Zhang,et al.  Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope , 2016, Journal of biomedical optics.

[16]  Rainer W Friedrich,et al.  Remote z-scanning with a macroscopic voice coil motor for fast 3D multiphoton laser scanning microscopy , 2016, Biomedical optics express.