Distribution system on‐line monitoring for detecting contamination and water quality changes

Concerns about water quality and possible intentional contamination of water distribution systems are making on-line monitoring an increasingly important priority for many water utilities. The city of Ann Arbor (Mich.) evaluated different water quality monitoring parameters, tested multiple manufacturers’ monitoring equipment, and evaluated how to effectively locate monitoring equipment within the distribution system to address these two concerns. A suite of modeling tools was used in this case study. Total chlorine, ultraviolet absorbance at 254 nm, conductivity, and dissolved oxygen were selected for monitoring based on pilot testing. When balancing costs and benefits, four stations for monitoring water quality and four stations for monitoring contamination events were found to be sufficient for the city. Only one location was common between water quality and security sites, and the number of security monitors needed was not affected by system demands. It was confirmed that it is critical to minimize response time in order to mitigate the effects of a contamination event.

[1]  Katherine A. Klise,et al.  Water quality change detection: multivariate algorithms , 2006, SPIE Defense + Commercial Sensing.

[2]  James G. Uber,et al.  Comparison of Physical Sampling and Real-Time Monitoring Strategies for Designing a Contamination Warning System in a Drinking Water Distribution System , 2006 .

[3]  Kenneth Carlson,et al.  Expanded Summary: Real‐time detection of intentional chemical contamination IN THE DISTRIBUTION SYSTEM , 2005 .

[4]  James G. Uber,et al.  Greedy Heuristic Methods for Locating Water Quality Sensors in Distribution Systems , 2004 .

[5]  Roy C. Haught,et al.  On–Line water quality parameters as indicators of distribution system contamination , 2007 .

[6]  Cynthia A. Phillips,et al.  Sensor Placement in Municipal Water Networks , 2003 .

[7]  Robert D. Carr,et al.  On the Placement of Imperfect Sensors in Municipal Water Networks , 2008 .

[8]  Cynthia A. Phillips,et al.  SPOT: A Sensor Placement Optimization Toolkit for Drinking Water Contaminant Warning System Design. , 2007 .

[9]  James G. Uber,et al.  The Threat Ensemble Vulnerability Assessment (TEVA) Program for Drinking Water Distribution System Security , 2004 .

[10]  David Byer,et al.  Real‐time detection of intentional chemical contamination in the distribution system , 2005 .

[11]  James G. Uber,et al.  A Model for Estimating the Acute Health Impacts Resulting from Consumption of Contaminated Drinking Water , 2005 .

[12]  M A Smith,et al.  Comparison of Six Dose‐Response Models for Use with Food‐Borne Pathogens , 1999, Risk analysis : an official publication of the Society for Risk Analysis.