Analysis of the Dynamic Performance of Self-Excited Induction Generators Employed in Renewable Energy Generation

Incentives, such as the Feed-in-tariff are expected to lead to continuous increase in the deployment of Small Scale Embedded Generation (SSEG) in the distribution network. Self-Excited Induction Generators (SEIG) represent a significant segment of potential SSEG. The quality of SEIG output voltage magnitude and frequency is investigated in this paper to support the SEIG operation for different network operating conditions. The dynamic behaviour of the SEIG resulting from disconnection, reconnection from/to the grid and potential operation in islanding mode is studied in detail. The local load and reactive power supply are the key factors that determine the SEIG performance, as they have significant influence on the voltage and frequency change after disconnection from the grid. Hence, the aim of this work is to identify the optimum combination of the reactive power supply (essential for self excitation of the SEIG) and the active load (essential for balancing power generation and demand). This is required in order to support the SEIG operation after disconnection from the grid, during islanding and reconnection to the grid. The results show that the generator voltage and speed (frequency) can be controlled and maintained within the statuary limits. This will enable safe disconnection and reconnection of the SEIG from/to the grid and makes it easier to operate in islanding mode.

[1]  Vivek Agarwal,et al.  A new variable speed constant voltage controller for self-excited induction generator , 2001 .

[2]  O. P. Malik,et al.  Analysis of self-excited induction generators , 1982 .

[3]  R. Bonert,et al.  Self-excited induction generator with excellent voltage and frequency control , 1998 .

[4]  Junji Tamura,et al.  Analysis of an isolated self-excited induction generator , 2000 .

[5]  J. Arrillaga,et al.  Static power conversion from self-excited induction generators , 1978 .

[6]  J. B. Ekanayake,et al.  Induction generators for small hydro schemes , 2002 .

[7]  Danny Sutanto,et al.  Steady-state and transient analysis of self-excited induction generators , 1989 .

[8]  Nick Jenkins,et al.  Investigation of Domestic Load Control to Provide Primary Frequency Response Using Smart Meters , 2012, IEEE Transactions on Smart Grid.

[9]  Anurag K. Srivastava,et al.  Impact of Distributed Generations With Energy Storage Devices on the Electric Grid , 2012, IEEE Systems Journal.

[10]  Jayaraman Ramachandran,et al.  Dynamic behaviour of single-phase induction generators during disconnection and reconnection to the grid , 2008 .

[11]  James F. Manwell,et al.  A power electronics based power shedding control for wind/diesel systems , 1992 .

[12]  ETSU KEL00235REP ASSESSMENT OF ISLANDED OPERATION OF DISTRIBUTION NETWORKS AND MEASURES FOR PROTECTION , 2001 .

[13]  E. Bim,et al.  Voltage Compensation of an Induction Generator with Long-Shunt Connection , 1989, IEEE Power Engineering Review.

[14]  Bhim Singh,et al.  Selection of capacitors for the self regulated short shunt self excited induction generator , 1995 .

[15]  Bhim Singh,et al.  Design-based performance evaluation of two-winding capacitor self- excited single-phase induction generator , 2003 .

[16]  S. Abdelkader Voltage stability assessment for systems with large wind power generation , 2009, 2009 44th International Universities Power Engineering Conference (UPEC).

[17]  M. Ebadian,et al.  Analytical investigation of the effect of wind farm equipped with SCIG on voltage stability , 2012, 2012 Second Iranian Conference on Renewable Energy and Distributed Generation.