Feasibility of Functional Cardiac MR Imaging in Mice Using A Clinical 3 Tesla Whole Body Scanner

Objectives:To test the feasibility of cardiac MR imaging in mice using a clinical 3 Tesla whole body MR system for structural and functional analysis. Standard protocols for bright blood cine imaging were adapted for murine dimensions. To validate measurements of functional parameters the MR data were compared with high-resolution echocardiographic measurements. Materials and Methods:Cardiac imaging was carried out in CD 1 wild-type mice (n = 8). MR imaging studies were performed using a clinical 3 Tesla MR system (Achieva, Philips). All mice received 2 MR scans and 1 echocardiographic evaluation. For optimal MR signal detection a dedicated solenoid receive-only coil was used. Electrocardiogram signal was recorded using a dedicated small animal electrocardiogram monitoring unit. For imaging we used a retrospectively triggered TFE sequence with a repetition time of 12 ms and an echo time of 4 ms. A dedicated software patch allowed for triggering of cardiac frequency of up to 600 BPM. Doppler-echocardiography was performed using a VisualSonics Vevo 770 high-resolution imaging system with a 30 MHz scanhead. Axial/lateral resolution was 40 of 100 &mgr;m and temporal resolution was 150 to 300 frames/s (B-mode) and 1000 frames/s (M-mode) depending on the setting. Results:MR imaging was successfully carried out in all mice with a sufficient temporal resolution and good signal-to-noise ratio and contrast-to-noise ratio levels allowing for identification of all relevant structures. Accordingly, there was a good scan-rescan reproducibility of MR measurements: Interassay coefficients of variance ranged from 4% for ejection fraction to 12% for endsystolic volume (ESV). Magnetic resonance imaging and echocardiography gave comparable results when using the same geometric model (Teichholz method): EDV: 60.2 ± 6.1 &mgr;L/59.1 ± 12.3 &mgr;L, ESV: 20.0 ± 2.6 &mgr;L/20.7 ± 7.7 &mgr;L, EF: 66.7% ± 4.0%/65.2% ± 9.9%, CO 19.5 ± 3.6 mL/17.9 ± 2.9 mL. Bland-Altman analysis gave acceptable limits of agreement between both methods: EDV (+28.2/−26.1), ESV (+16.3/−17.7), EF (+19.0/−16.1), CO (10.7/−7.5). When applying the Simpson's method MR volume estimates were significantly higher compared with echocardiography resulting in a lower estimate for the ejection fraction (60% ± 3.9% vs. 66.7% ± 4.0%). Conclusions:Cardiac MR imaging of mice using a clinical 3 Tesla MR system for functional analysis is feasible with sufficient spatial and temporal resolution, good repeatability and reliable results when compared with high-resolution echocardiography.

[1]  D J Pennell,et al.  Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? , 2000, European heart journal.

[2]  Jörg Stypmann,et al.  Doppler Ultrasound in Mice , 2007, Echocardiography.

[3]  B. Lüderitz,et al.  Echocardiographic Assessment of Left Ventricular Mass in Neonatal and Adult Mice: Accuracy of Different Echocardiographic Methods , 2006, Echocardiography.

[4]  A. Ghanem,et al.  Increasing myocardial contraction and blood pressure in C57BL/6 mice during early postnatal development. , 2003, American journal of physiology. Heart and circulatory physiology.

[5]  Maria Drangova,et al.  Longitudinal Follow-up of Cardiac Structure and Functional Changes in an Infarct Mouse Model Using Retrospectively Gated Micro-Computed Tomography , 2008, Investigative radiology.

[6]  Dara L Kraitchman,et al.  Cardiac magnetic resonance imaging in small rodents using clinical 1.5 T and 3.0 T scanners. , 2007, Methods.

[7]  Claudia E Korcarz,et al.  Use of echocardiography for the phenotypic assessment of genetically altered mice. , 2003, Physiological genomics.

[8]  Stefan Neubauer,et al.  How to perform an accurate assessment of cardiac function in mice using high-resolution magnetic resonance imaging. , 2006, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[9]  A. DeMaria,et al.  Recommendations Regarding Quantitation in M-Mode Echocardiography: Results of a Survey of Echocardiographic Measurements , 1978, Circulation.

[10]  P. Kotwinski,et al.  The role of cardiovascular magnetic resonance in the evaluation of patients with heart failure , 2004, Expert review of cardiovascular therapy.

[11]  G. Breithardt,et al.  Age and gender related reference values for transthoracic Doppler-echocardiography in the anesthetized CD1 mouse , 2006, The International Journal of Cardiovascular Imaging.

[12]  Dudley J Pennell,et al.  Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. , 2002, The American journal of cardiology.

[13]  Gerald J Berry,et al.  Dual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 t , 2006, Magnetic resonance in medicine.

[14]  J. Stypmann,et al.  Cardiovascular characterization of Pkd2(+/LacZ) mice, an animal model for the autosomal dominant polycystic kidney disease type 2 (ADPKD2). , 2007, International journal of cardiology.

[15]  Stefan Neubauer,et al.  Quantitative 3-Dimensional Echocardiography for Accurate and Rapid Cardiac Phenotype Characterization in Mice , 2004, Circulation.

[16]  U. Reiter,et al.  On the value of geometry-based models for left ventricular volumetry in magnetic resonance imaging and electron beam tomography: a Bland-Altman analysis. , 2004, European journal of radiology.

[17]  D. Altman,et al.  Applying the right statistics: analyses of measurement studies , 2003, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[18]  K. Clarke,et al.  Cine‐MRI versus two‐dimensional echocardiography to measure in vivo left ventricular function in rat heart , 2008, NMR in biomedicine.

[19]  Ronald M Peshock,et al.  Magnetic Resonance Imaging and Invasive Evaluation of Development of Heart Failure in Transgenic Mice With Myocardial Expression of Tumor Necrosis Factor-α , 1999 .

[20]  C. Peters,et al.  Lysosomal, cytoskeletal, and metabolic alterations in cardiomyopathy of cathepsin L knockout mice , 2006, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[21]  J. Stypmann,et al.  LAMP-2 deficient mice show depressed cardiac contractile function without significant changes in calcium handling , 2006, Basic Research in Cardiology.

[22]  Christopher Francois,et al.  Cardiac Image Modeling Tool for Quantitative Analysis of Global and Regional Cardiac Wall Motion , 2009, Investigative radiology.

[23]  P. Wielopolski,et al.  Addition of the Long-Axis Information to Short-Axis Contours Reduces Interstudy Variability of Left-Ventricular Analysis in Cardiac Magnetic Resonance Studies , 2008, Investigative radiology.

[24]  Frederick H Epstein,et al.  MR in mouse models of cardiac disease , 2007, NMR in biomedicine.

[25]  P. Doevendans,et al.  Cardiovascular phenotyping in mice. , 1998, Cardiovascular research.