Monitoring thrombin generation: Is addition of corn trypsin inhibitor needed?

Thrombin generation monitoring has the potential to be used as a clinical diagnostic tool in the near future. However, robust preanalytical conditions may be required, and one factor that has been reported is in-vitro contact activation that might influence in-vitro measurements of thrombin generation and thereby act as an unpredictable pre-analytical variable. The aim of the current study was to investigate the influence of contact activation and the necessity of corn trypsin inhibitor (CTI) to abolish contact activation in thrombin generation measurements at low tissue factor (TF) concentrations. Thrombin generation was performed using the calibrated automated thrombinoscopy (CAT), thereby determining the endogenous thrombin potential (ETP), peak height, and the lag time, in plasma obtained from healthy volunteers. Addition of CTI after plasma preparation had no significant influence on thrombin generation triggered with 0.5 pM TF or higher, as demonstrated by unaltered ETP and lag time values between analyses with and without CTI. Addition of CTI before blood collection reduced thrombin generation triggered with 0.5 pM TF: both the ETP and peak height were significantly reduced compared to no CTI addition. In contrast, thrombin generation remained unaltered at a 1 pM TF trigger or above. This study demonstrates that addition of CTI after plasma separation is not necessary when triggering with TF concentrations of 0.5 pM and higher. Furthermore, it was demonstrated that it is not needed to pre-fill blood collecting tubes with CTI when measuring thrombin generation at TF concentrations of >/=1 pM.

[1]  M. Prins,et al.  Assessment of thrombin generation II: Validation of the Calibrated Automated Thrombogram in platelet-poor plasma in a clinical laboratory , 2008, Thrombosis and Haemostasis.

[2]  U. Scholz,et al.  Thrombin generation in severe haemophilia A and B: the endogenous thrombin potential in platelet-rich plasma , 2003, Thrombosis and Haemostasis.

[3]  H. Hemker,et al.  Evaluation of thrombin generating capacity in plasma from patients with haemophilia A and B , 2005, Thrombosis and Haemostasis.

[4]  H. ten Cate,et al.  The blood coagulation system as a molecular machine. , 2003, BioEssays : news and reviews in molecular, cellular and developmental biology.

[5]  T. Baglin,et al.  High rate of unprovoked recurrent venous thrombosis is associated with high thrombin‐generating potential in a prospective cohort study , 2008, Journal of thrombosis and haemostasis : JTH.

[6]  K. Mann,et al.  Blood clotting in minimally altered whole blood. , 1996, Blood.

[7]  M. Prins,et al.  Thrombin generation in patients after acute deep-vein thrombosis , 2008, Thrombosis and Haemostasis.

[8]  T. Baglin,et al.  Effect of standardization and normalization on imprecision of calibrated automated thrombography: an international multicentre study , 2007, British journal of haematology.

[9]  H. Hemker,et al.  Phenotyping the haemostatic system by thrombography--potential for the estimation of thrombotic risk. , 2004, Thrombosis research.

[10]  S. Eichinger,et al.  Prediction of recurrent venous thromboembolism by endogenous thrombin potential and D-dimer. , 2008, Clinical chemistry.

[11]  B. Binder,et al.  Identification Of Patients At Low Risk For Recurrent Venous Thromboembolism By Measuring Thrombin Generation , 2006 .

[12]  C. Hack,et al.  The plasma kallikrein–kinin system and risk of cardiovascular disease in men , 2007, Journal of thrombosis and haemostasis : JTH.

[13]  Thrombomodulin-modified thrombin generation after in vivo recombinant factor VIII treatment in severe hemophilia A , 2008, Haematologica.

[14]  R. van Oerle,et al.  Coagulation factors and the protein C system as determinants of thrombin generation in a normal population , 2007, Journal of thrombosis and haemostasis : JTH.

[15]  M. Makris,et al.  Corn trypsin inhibitor in fluorogenic thrombin-generation measurements is only necessary at low tissue factor concentrations and influences the relationship between factor VIII coagulant activity and thrombogram parameters , 2008, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[16]  T. Baglin,et al.  Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition , 2004, Journal of thrombosis and haemostasis : JTH.