Accelerated SPECT image reconstruction with FBP and an image enhancement convolutional neural network

BackgroundMonte Carlo-based iterative reconstruction to correct for photon scatter and collimator effects has been proven to be superior over analytical correction schemes in single-photon emission computed tomography (SPECT/CT), but it is currently not commonly used in daily clinical practice due to the long associated reconstruction times. We propose to use a convolutional neural network (CNN) to upgrade fast filtered back projection (FBP) image quality so that reconstructions comparable in quality to the Monte Carlo-based reconstruction can be obtained within seconds.ResultsA total of 128 technetium-99m macroaggregated albumin pre-treatment SPECT/CT scans used to guide hepatic radioembolization were available. Four reconstruction methods were compared: FBP, clinical reconstruction, Monte Carlo-based reconstruction, and the neural network approach. The CNN generated reconstructions in 5 sec, whereas clinical reconstruction took 5 min and the Monte Carlo-based reconstruction took 19 min. The mean squared error of the neural network approach in the validation set was between that of the Monte Carlo-based and clinical reconstruction, and the lung shunting fraction difference was lower than 2 percent point. A phantom experiment showed that quantitative measures required in radioembolization were accurately retrieved from the CNN-generated reconstructions.ConclusionsFBP with an image enhancement neural network provides SPECT reconstructions with quality close to that obtained with Monte Carlo-based reconstruction within seconds.

[1]  Jeffrey A. Fessler,et al.  Improved quantitative 90Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling , 2017, Medical physics.

[2]  M. Viergever,et al.  A Dual-layer Detector for Simultaneous Fluoroscopic and Nuclear Imaging. , 2019, Radiology.

[3]  H.W.A.M. de Jong,et al.  Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[4]  M Båth,et al.  Fast GPU-based Monte Carlo code for SPECT/CT reconstructions generates improved 177Lu images , 2018, EJNMMI Physics.

[5]  Simon R. Cherry chapter 16 – Tomographic Reconstruction in Nuclear Medicine , 2012 .

[6]  Junshen Xu,et al.  200x Low-dose PET Reconstruction using Deep Learning , 2017, ArXiv.

[7]  Sandra van der Velden,et al.  Fast technetium‐99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry , 2018, Medical physics.

[8]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[9]  Freek J. Beekman,et al.  Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Thomas Brox,et al.  U-Net: Convolutional Networks for Biomedical Image Segmentation , 2015, MICCAI.

[11]  D. Ganger,et al.  Same-day 90Y radioembolization: implementing a new treatment paradigm , 2016, European Journal of Nuclear Medicine and Molecular Imaging.

[12]  Marnix G E H Lam,et al.  Quantitative Monte Carlo-based holmium-166 SPECT reconstruction. , 2013, Medical physics.

[13]  Harpreet Wasan,et al.  Radioembolization for the Treatment of Liver Tumors: General Principles , 2012, American journal of clinical oncology.

[14]  Bram van Ginneken,et al.  A survey on deep learning in medical image analysis , 2017, Medical Image Anal..

[15]  Remco Bastiaannet,et al.  Respiratory motion compensation in interventional liver SPECT using simultaneous fluoroscopic and nuclear imaging , 2019, Medical physics.

[16]  Jieqing Jiao,et al.  Fast PET reconstruction using Multi-scale Fully Convolutional Neural Networks , 2017, ArXiv.

[17]  Freek J. Beekman,et al.  Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection , 1999 .

[18]  Michael Ljungberg,et al.  Monte Carlo-based SPECT reconstruction within the SIMIND framework , 2018, Physics in medicine and biology.

[19]  Yuan Yu,et al.  TensorFlow: A system for large-scale machine learning , 2016, OSDI.

[20]  Hilde van der Togt,et al.  Publisher's Note , 2003, J. Netw. Comput. Appl..

[21]  Max A. Viergever,et al.  Quantitative Monte Carlo–Based 90Y SPECT Reconstruction , 2013, The Journal of Nuclear Medicine.

[22]  Sandra van der Velden,et al.  Fast quantitative reconstruction with focusing collimators for liver SPECT , 2018, EJNMMI Physics.

[23]  Abass Alavi,et al.  Insights into the Dose–Response Relationship of Radioembolization with Resin 90Y-Microspheres: A Prospective Cohort Study in Patients with Colorectal Cancer Liver Metastases , 2016, The Journal of Nuclear Medicine.

[24]  R. Jaszczak,et al.  Improved SPECT quantification using compensation for scattered photons. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Michael Unser,et al.  Convolutional Neural Networks for Inverse Problems in Imaging: A Review , 2017, IEEE Signal Processing Magazine.

[26]  M. Viergever,et al.  Performance of a dual-layer scanner for hybrid SPECT/CBCT , 2019, Physics in medicine and biology.

[27]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[28]  Marnix G E H Lam,et al.  Safety of a Scout Dose Preceding Hepatic Radioembolization with 166Ho Microspheres , 2015, The Journal of Nuclear Medicine.