Integrated calibration and magnetic disturbance compensation of three-axis magnetometers

Abstract Technological limitations in sensor manufacturing and unwanted magnetic fields will corrupt the measurements of three-axis magnetometers. An experiment with four different magnetic disturbance situations is designed, and the influence of hard-iron and soft-iron material is analyzed. The calibration method with magnetic disturbance parameters is proposed for calibration and magnetic disturbance compensation of three axis magnetometers. It is not necessary to compute pseudo-linear parameters, thus the integrated parameters are computed directly by solving nonlinear equations. To employ this method, a nonmagnetic rotation equipment, a CZM-3 proton magnetometer, a DM-050 three-axis magnetometer, two magnets and two steel tubes are used. Calibration performance is discussed in the four situations. Compared with several traditional calibration methods, experiment results show that the proposed method has better integrated compensation performance in all situations, and error is reduced by several orders of magnitude. After compensation, RMS error is reduced from 10797.962 nT to 15.309 nT when the big magnet and steel tube are deployed. It suggests an useful method for calibration and magnetic disturbance compensation of three-axis magnetometers.

[1]  Fritz Primdahl,et al.  Ørsted Pre-Flight Magnetometer Calibration Mission , 2003 .

[2]  Wouter Olthuis,et al.  Procedure for in-use calibration of triaxial accelerometers , 1997 .

[3]  Pavel Ripka,et al.  A.c. magnetic-field measurement using the fluxgate , 1995 .

[4]  Feilu Luo,et al.  Calibration of three-axis magnetometers with differential evolution algorithm , 2013 .

[5]  D.S. Bernstein,et al.  Calibrating a triaxial accelerometer-magnetometer - using robotic actuation for sensor reorientation during data collection , 2005, IEEE Control Systems.

[6]  John L. Crassidis,et al.  Real-Time Attitude-Independent Three-Axis Magnetometer Calibration , 2005 .

[7]  Pavel Ripka,et al.  Automated system for the calibration of magnetometers , 2009 .

[8]  Sangkyung Sung,et al.  Error Calibration of Magnetometer Using Nonlinear Integrated Filter Model With Inertial Sensors , 2009, IEEE Transactions on Magnetics.

[9]  Yang Gao,et al.  A new magnetic compass calibration algorithm using neural networks , 2005 .

[10]  Carlos Silvestre,et al.  Geometric Approach to Strapdown Magnetometer Calibration in Sensor Frame , 2011, IEEE Transactions on Aerospace and Electronic Systems.

[11]  Feilu Luo,et al.  Calibration of three-axis fluxgate magnetometers with nonlinear least square method , 2013 .

[12]  Marko Topič,et al.  Calibration and data fusion solution for the miniature attitude and heading reference system , 2007 .

[13]  Suzanne Lesecq,et al.  Calibration methods for inertial and magnetic sensors , 2009 .

[14]  Timo Pylvänäinen,et al.  Automatic and adaptive calibration of 3D field sensors , 2008 .

[15]  Nicolas Petit,et al.  Iterative calibration method for inertial and magnetic sensors , 2009, Proceedings of the 48h IEEE Conference on Decision and Control (CDC) held jointly with 2009 28th Chinese Control Conference.

[16]  Feilu Luo,et al.  Calibration of a fluxgate magnetometer array and its application in magnetic object localization , 2013 .

[17]  Pavel Ripka,et al.  Errors of AMR compass and methods of their compensation , 2006 .

[18]  Demoz Gebre-Egziabher,et al.  Calibration of Strapdown Magnetometers in Magnetic Field Domain , 2006 .

[19]  G.H. Elkaim,et al.  Extension of a two-step calibration methodology to include nonorthogonal sensor axes , 2008, IEEE Transactions on Aerospace and Electronic Systems.

[20]  Demoz Gebre-Egziabher,et al.  Magnetometer Autocalibration Leveraging Measurement Locus Constraints , 2007 .

[21]  Hans-Ulrich Auster,et al.  Calibration of flux-gate magnetometers using relative motion , 2002 .

[22]  Zhaoying Zhou,et al.  Calibration of three-dimensional integrated sensors for improved system accuracy , 2006 .

[23]  Fritz Primdahl,et al.  Scalar calibration of vector magnetometers , 2000 .