An Evaluation of a GLR Control Chart for Monitoring the Process Mean

This paper considers the problem of monitoring the mean of a normally distributed process variable when the objective is to effectively detect both small and large shifts in this mean. The performance of a generalized likelihood ratio (GLR) control chart is evaluated, where the likelihood ratio is based on a moving window of past observations. The performance of the GLR chart is compared with the performance of other options, such as combinations of Shewhart and cumulative sum (CUSUM) charts and an adaptive CUSUM chart, that have been proposed for detecting a wide range of shift sizes. Performance is evaluated for sustained shifts, transient shifts, and drifts in the mean. It is shown that the overall performance of the GLR chart is at least as good as these other options. These other options have multiple control-chart parameters that allow for the charts to be tuned to be more sensitive to certain shifts that may be of interest. However, the GLR chart does not require users to specify the values of any control-chart parameters other than the size of the window and the control limit. We recommend a specific window size and provide a table of control limits corresponding to specified values of the false-alarm rate, so it is very easy to design the GLR chart for use in applications. Simulating the performance of the GLR chart is time consuming, but approximating the GLR chart with a set of CUSUM charts provides a much faster way of evaluating the performance of the GLR chart for research purposes.

[1]  Wei Jiang,et al.  A Markov Chain Model for the Adaptive CUSUM Control Chart , 2006 .

[2]  Marion R. Reynolds,et al.  Comparisons of Some Exponentially Weighted Moving Average Control Charts for Monitoring the Process Mean and Variance , 2006, Technometrics.

[3]  William H. Woodall,et al.  Introduction to Statistical Quality Control, Fifth Edition , 2005 .

[4]  Fugee Tsung,et al.  CUSUM and EWMA multi-charts for detecting a range of mean shifts , 2007 .

[5]  E. S. Page CONTINUOUS INSPECTION SCHEMES , 1954 .

[6]  Ross Sparks,et al.  CUSUM Charts for Signalling Varying Location Shifts , 2000 .

[7]  Wei Jiang,et al.  Adaptive CUSUM procedures with EWMA-based shift estimators , 2008 .

[8]  Fugee Tsung,et al.  Dual CUSUM control schemes for detecting a range of mean shifts , 2005 .

[9]  Jianjun Shi,et al.  The GLRT for statistical process control of autocorrelated processes , 1999 .

[10]  Edit Gombay,et al.  Sequential change-point detection with likelihood ratios , 2000 .

[11]  Marion R. Reynolds,et al.  Control Charts and the Efficient Allocation of Sampling Resources , 2004, Technometrics.

[12]  James M. Lucas,et al.  Combined Shewhart-CUSUM Quality Control Schemes , 1982 .

[13]  T. Lai Sequential changepoint detection in quality control and dynamical systems , 1995 .

[14]  Giovanna Capizzi Design of change detection algorithms based on the generalized likelihood ratio test , 2001 .

[15]  Vladimir Dragalin The design and analysis of 2-CUSUM procedure , 1997 .

[16]  T. Lai SEQUENTIAL ANALYSIS: SOME CLASSICAL PROBLEMS AND NEW CHALLENGES , 2001 .

[17]  Sujin Kim,et al.  Optimal Design of a CUSUM Chart for a Mean Shift of Unknown Size , 2010 .

[18]  Zachary G. Stoumbos,et al.  Should Exponentially Weighted Moving Average and Cumulative Sum Charts Be Used With Shewhart Limits? , 2005, Technometrics.

[19]  Ying Liu,et al.  An enhanced adaptive CUSUM control chart , 2009 .

[20]  George C. Runger,et al.  Control Charts for Monitoring Fault Signatures: Cuscore versus GLR , 2003 .

[21]  G. Lorden PROCEDURES FOR REACTING TO A CHANGE IN DISTRIBUTION , 1971 .

[22]  J. Westgard,et al.  Combined Shewhart-cusum control chart for improved quality control in clinical chemistry. , 1977, Clinical chemistry.

[23]  Mei Yang,et al.  Optimization designs of the combined Shewhart-CUSUM control charts , 2008, Comput. Stat. Data Anal..

[24]  Marion R. Reynolds,et al.  Should Observations Be Grouped for Effective Process Monitoring? , 2004 .

[25]  D. Siegmund,et al.  Using the Generalized Likelihood Ratio Statistic for Sequential Detection of a Change-Point , 1995 .

[26]  Giovanna Capizzi,et al.  An Adaptive Exponentially Weighted Moving Average Control Chart , 2003, Technometrics.

[27]  Fred Spiring,et al.  Introduction to Statistical Quality Control , 2007, Technometrics.

[28]  Douglas M. Hawkins,et al.  The Changepoint Model for Statistical Process Control , 2003 .

[29]  Douglas M. Hawkins,et al.  Statistical Process Control for Shifts in Mean or Variance Using a Changepoint Formulation , 2005, Technometrics.

[30]  Mahmoud A. Mahmoud,et al.  The Inertial Properties of Quality Control Charts , 2005, Technometrics.

[31]  Rickie J. Domangue,et al.  Some omnibus exponentially weighted moving average statistical process monitoring schemes , 1991 .

[32]  A. Willsky,et al.  A generalized likelihood ratio approach to the detection and estimation of jumps in linear systems , 1976 .