Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results

A diffusion imaging method with a tetrahedral sampling pattern has been developed for high‐sensitivity diffusion analysis. The tetrahedral gradient pattern consists of four different combinations of x, y, and z gradients applied simultaneously at full strength to uniformly measure diffusion in four different directions. Signal‐to‐noise can be increased by up to a factor of about three using this approach, compared with diffusion measurements made using separately applied x, y, and z gradients. A mathematical formalism is presented describing six fundamental parameters: the directionally averaged diffusion coefficient D and diffusion element anisotropies η and ε which are rotationally invariant, and diffusion ellipsoid orientation angles θ, ϕ, and Ψ which are rotationally variant. These six parameters contain all the information in the symmetric diffusion tensor D. Principal diffusion coefficients, reduced anisotropies, and other rotational invariants are further defined. It is shown that measurement of off‐diagonal tensor elements is essential to assess anisotropy and orientation, and that the only parameter which can be measured with the orthogonal method is D. In cases of axial diffusion symmetry (e.g., fibers), the four tetrahedral diffusion measurements efficiently enable determination of D, η, θ, and ϕ which contain all the diffusion information. From these four parameters, the diffusion parallel and perpendicular to the symmetry axis (D1 and D1) and the axial anisotropy A can be determined. In more general cases, the six fundamental parameters can be determined with two additional diffusion measurements. Tetrahedral diffusion sequences were implemented on a clinical MR system. A muscle phantom demonstrates orientation independence of D, D1, D1, and A for large changes in orientation angles. Sample background gradients and diffusion gradient imbalances were directly measured and found to be insignificant in most cases.

[1]  H. C. Torrey Bloch Equations with Diffusion Terms , 1956 .

[2]  H. Carr,et al.  DIFFUSION AND NUCLEAR SPIN RELAXATION IN WATER , 1958 .

[3]  J. Freed Anisotropic Rotational Diffusion and Electron Spin Resonance Linewidths , 1964 .

[4]  E. Stejskal Use of Spin Echoes in a Pulsed Magnetic‐Field Gradient to Study Anisotropic, Restricted Diffusion and Flow , 1965 .

[5]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[6]  C F Hazlewood,et al.  Nuclear magnetic resonance measurement of skeletal muscle: anisotrophy of the diffusion coefficient of the intracellular water. , 1976, Biophysical journal.

[7]  R. Cherry Measurement of protein rotational diffusion in membranes by flash photolysis. , 1978, Methods in enzymology.

[8]  R L Ehman,et al.  Translational molecular self-diffusion in magnetic resonance imaging. II. Measurement of the self-diffusion coefficient. , 1984, Investigative radiology.

[9]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[10]  Bruce R. Rosen,et al.  MR Diffusion Imaging of the Human Brain , 1990, Journal of computer assisted tomography.

[11]  J. Pekar,et al.  Echo-planar imaging of intravoxel incoherent motion. , 1990, Radiology.

[12]  J. Tsuruda,et al.  Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system. , 1990, Radiology.

[13]  J. Kurhanewicz,et al.  Diffusion-weighted MR imaging of acute stroke: correlation with T2-weighted and magnetic susceptibility-enhanced MR imaging in cats. , 1990, AJNR. American journal of neuroradiology.

[14]  J V Hajnal,et al.  Normal and abnormal white matter tracts shown by MR imaging using directional diffusion weighted sequences. , 1990, Journal of computer assisted tomography.

[15]  T. Chenevert,et al.  Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo. , 1990, Radiology.

[16]  J. Kucharczyk,et al.  Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopy , 1990, Magnetic resonance in medicine.

[17]  J. Pekar,et al.  MR color mapping of myelin fiber orientation. , 1991, Journal of computer assisted tomography.

[18]  Jeffrey J. Neil,et al.  Detection of pseudodiffusion in rat brain following blood substitution with perfluorocarbon , 1992 .

[19]  Ultrafast MR imaging of water mobility: Animal models of altered cerebral perfusion , 1992, Journal of magnetic resonance imaging : JMRI.

[20]  P. Basser,et al.  Estimation of the effective self-diffusion tensor from the NMR spin echo. , 1994, Journal of magnetic resonance. Series B.

[21]  P. Basser,et al.  MR diffusion tensor spectroscopy and imaging. , 1994, Biophysical journal.

[22]  P van Gelderen,et al.  Water diffusion and acute stroke , 1994, Magnetic resonance in medicine.

[23]  K K Kwong,et al.  Anisotropy of water diffusion in the myocardium of the rat. , 1994, Circulation research.

[24]  P. Basser,et al.  Analytical Expressions for the b Matrix in NMR Diffusion Imaging and Spectroscopy , 1994 .

[25]  P. V. van Zijl,et al.  Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan , 1995, Magnetic resonance in medicine.