3D reconstruction of small bowel lesions using stereo camera-based capsule endoscopy

Three-dimensional (3D) reconstruction of capsule endoscopic images has been attempted for a long time to obtain more information on small bowel structures. Due to the limited hardware resources of capsule size and battery capacity, software approaches have been studied but have mainly exhibited inherent limitations. Recently, stereo camera-based capsule endoscopy, which can perform hardware-enabled 3D reconstruction, has been developed. We aimed to evaluate the feasibility of newly developed 3D capsule endoscopy in clinical practice. This study was a prospective, single-arm, feasibility study conducted at two university-affiliated hospitals in South Korea. Small bowel evaluation was performed using a newly developed 3D capsule endoscope for patients with obscure gastrointestinal bleeding, suspected or established Crohn’s disease, small bowel tumors, and abdominal pain of unknown origin. We assessed the technical limitations, performance, and safety of the new capsule endoscope. Thirty-one patients (20 men and 11 women; mean age: 44.5 years) were enrolled. There was no technical defect preventing adequate visualization of the small bowel. The overall completion rate was 77.4%, the detection rate was 64.5%, and there was no capsule retention. All capsule endoscopic procedures were completed uneventfully. In conclusion, newly developed 3D capsule endoscopy was safe and feasible, showing similar performance as conventional capsule endoscopy. Newly added features of 3D reconstruction and size measurement are expected to be useful in the characterization of subepithelial tumours.

[1]  Emanuele Rondonotti,et al.  Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline , 2015, Endoscopy.

[2]  V. Konda,et al.  Wireless Capsule Endoscopy , 2020, Geriatric Gastroenterology.

[3]  Esther Hawkes,et al.  PTH-024 Novel capsule endoscope with 3D reconstruction and lesions size calculation: first study with MiroCam MC4000 , 2019 .

[4]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.

[5]  Daniel Rueckert,et al.  Patch-Based Techniques in Medical Imaging , 2016, Lecture Notes in Computer Science.

[6]  Alessandro Mussetto,et al.  MiroCam capsule for obscure gastrointestinal bleeding: a prospective, single centre experience. , 2013, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[7]  J. Affeldt,et al.  The feasibility study , 2019, The Information System Consultant’s Handbook.

[8]  D. Chang,et al.  Indications for Detection, Completion, and Retention Rates of Small Bowel Capsule Endoscopy Based on the 10-Year Data from the Korean Capsule Endoscopy Registry , 2015, Clinical endoscopy.

[9]  Yun Jeong Lim,et al.  Current Status and Research into Overcoming Limitations of Capsule Endoscopy , 2016, Clinical endoscopy.

[10]  Z. Liao,et al.  Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. , 2010, Gastrointestinal endoscopy.

[11]  E. Toth,et al.  Capsule retention related to small bowel capsule endoscopy: a large European single-center 10-year clinical experience , 2017, United European gastroenterology journal.

[12]  Alexandros Karargyris,et al.  Utility of 3-dimensional image reconstruction in the diagnosis of small-bowel masses in capsule endoscopy (with video). , 2014, Gastrointestinal endoscopy.

[13]  Alexandros Karargyris,et al.  Three-dimensional representation software as image enhancement tool in small-bowel capsule endoscopy: a feasibility study. , 2013, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[14]  Olivier Romain,et al.  Prototype of Video Endoscopic Capsule With 3-D Imaging Capabilities , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[15]  E. Mohammadi,et al.  Barriers and facilitators related to the implementation of a physiological track and trigger system: A systematic review of the qualitative evidence , 2017, International journal for quality in health care : journal of the International Society for Quality in Health Care.

[16]  E. Rondonotti,et al.  Complications, limitations, and failures of capsule endoscopy: a review of 733 cases. , 2005, Gastrointestinal endoscopy.

[17]  Olivier Romain,et al.  A System for an Accurate 3D Reconstruction in Video Endoscopy Capsule , 2009, EURASIP J. Embed. Syst..

[18]  J. Kim,et al.  Outcomes and Management Strategies for Capsule Retention: A Korean Capsule Endoscopy Nationwide Database Registry Study , 2019, Endoscopy.

[19]  Alexandros Karargyris,et al.  Evaluation of 4 three-dimensional representation algorithms in capsule endoscopy images. , 2013, World journal of gastroenterology.

[20]  G. Iddan,et al.  Wireless capsule endoscopy , 2003, Gut.

[21]  Su Hwan Kim,et al.  Current Status of Interpretation of Small Bowel Capsule Endoscopy , 2018, Clinical endoscopy.

[22]  BarretoZuiga Rafael,et al.  Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small bowel disorders , 2015 .

[23]  R. Koprowski Overview of technical solutions and assessment of clinical usefulness of capsule endoscopy , 2015, BioMedical Engineering OnLine.

[24]  A. Karargyris,et al.  Three-dimensional image reconstruction in capsule endoscopy. , 2012, World journal of gastroenterology.

[25]  Xing Mei,et al.  On building an accurate stereo matching system on graphics hardware , 2011, 2011 IEEE International Conference on Computer Vision Workshops (ICCV Workshops).

[26]  C. Hassan,et al.  Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review , 2018, Endoscopy.