This paper describes an activity-dependent intracortical microstimulation (ICMS) system-on-chip (SoC) that converts extracellular neural spikes recorded from one brain region to electrical stimuli delivered to another brain region in real time in vivo. The 10.9-mm2 SoC incorporates two identical 4-channel modules, each comprising an analog recording front-end with total input noise voltage of 3.12 μVrms and noise efficiency factor (NEF) of 2.68, 5.9-μW 10-bit successive approximation register analog-to-digital converters (SAR ADCs), 12.4-μW digital spike discrimination processor, and a programmable constant-current microstimulating back-end that delivers up to 94.5 μA with 6-bit resolution to stimulate the cortical tissue when triggered by neural activity. For autonomous operation, the SoC also integrates biasing and clock generation circuitry, frequency-shift-keyed (FSK) transmitter at 433 MHz, and dc-dc converter that generates a power supply of 5.05 V for the microstimulating back-end from a single 1.5-V battery. Measured results from electrical performance characterization and biological experiments with anesthetized rats are presented from a prototype chip fabricated in AMS 0.35 μm two-poly four-metal (2P/4M) CMOS. A noise analysis for the selected low-noise amplifier (LNA) topology is presented that obtains a minimum NEF of 2.33 for a practical design given the technology parameters and power supply voltage. Future considerations in the SoC design with respect to silicon area and power consumption when increasing the number of channels are also discussed.

[1]  W.M.C. Sansen,et al.  A micropower low-noise monolithic instrumentation amplifier for medical purposes , 1987 .

[2]  Y. Tsividis Operation and modeling of the MOS transistor , 1987 .

[3]  K. Horch,et al.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[4]  M. Nicolelis,et al.  Reconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings , 1997, Neuron.

[5]  Michel Declercq,et al.  A high-efficiency CMOS voltage doubler , 1998, IEEE J. Solid State Circuits.

[6]  K. S Guillory,et al.  A 100-channel system for real time detection and storage of extracellular spike waveforms , 1999, Journal of Neuroscience Methods.

[7]  J. Rauschecker,et al.  Sending Sound to the Brain , 2002, Science.

[8]  R. R. Harrison,et al.  A low-power low-noise CMOS amplifier for neural recording applications , 2003, IEEE J. Solid State Circuits.

[9]  Kristofer S. J. Pister,et al.  An ultralow-energy ADC for Smart Dust , 2003, IEEE J. Solid State Circuits.

[10]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[11]  K. Halonen,et al.  A micropower 2 MHz CMOS frequency reference for capacitive sensor applications , 2005, Proceedings of the 2005 European Conference on Circuit Theory and Design, 2005..

[12]  T.W. Berger,et al.  Restoring lost cognitive function , 2005, IEEE Engineering in Medicine and Biology Magazine.

[13]  Maysam Ghovanloo,et al.  A compact large Voltage-compliance high output-impedance programmable current source for implantable microstimulators , 2005, IEEE Transactions on Biomedical Engineering.

[14]  Andrew Jackson,et al.  An autonomous implantable computer for neural recording and stimulation in unrestrained primates , 2005, Journal of Neuroscience Methods.

[15]  R. Nudo Mechanisms for recovery of motor function following cortical damage , 2006, Current Opinion in Neurobiology.

[16]  E. Fetz,et al.  The neurochip BCI: towards a neural prosthesis for upper limb function , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  J. Weiland,et al.  Intraocular retinal prosthesis , 2006, IEEE Engineering in Medicine and Biology Magazine.

[18]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[19]  Mohammad M. Ahmadi,et al.  A new modeling and optimization of gain-boosted cascode amplifier for high-speed and low-voltage applications , 2006, IEEE Transactions on Circuits and Systems II: Express Briefs.

[20]  E. Fetz,et al.  Long-term motor cortex plasticity induced by an electronic neural implant , 2006, Nature.

[21]  Guido Torelli,et al.  A low-ripple voltage tripler , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[22]  M. Azin,et al.  Comparisons of FIR and IIR Implementations of a Subtraction-Based Stimulus Artifact Rejection Algorithm , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  M. Ortmanns,et al.  A 232-Channel Epiretinal Stimulator ASIC , 2007, IEEE Journal of Solid-State Circuits.

[24]  Eric T. Shea-Brown,et al.  Toward closed-loop optimization of deep brain stimulation for Parkinson's disease: concepts and lessons from a computational model , 2007, Journal of neural engineering.

[25]  Rahul Sarpeshkar,et al.  A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[26]  Rahul Sarpeshkar,et al.  An Energy-Efficient Micropower Neural Recording Amplifier , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[27]  A.-T. Avestruz,et al.  A 2 $\mu\hbox{W}$ 100 nV/rtHz Chopper-Stabilized Instrumentation Amplifier for Chronic Measurement of Neural Field Potentials , 2007, IEEE Journal of Solid-State Circuits.

[28]  Timothy G. Constandinou,et al.  A Partial-Current-Steering Biphasic Stimulation Driver for Vestibular Prostheses , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[29]  A.-T. Avestruz,et al.  A 5 $\mu$ W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces , 2008, IEEE Journal of Solid-State Circuits.

[30]  Pedram Mohseni,et al.  A high-output-impedance current microstimulator for anatomical rewiring of cortical circuitry , 2008, 2008 IEEE International Symposium on Circuits and Systems.

[31]  P. Mohseni,et al.  A 94-μW 10-b neural recording front-end for an implantable brain-machine-brain interface device , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[32]  Refet Firat Yazicioglu,et al.  A 200 $\mu$ W Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems , 2008, IEEE Journal of Solid-State Circuits.

[33]  Dennis J. McFarland,et al.  Brain-Computer Interface Operation of Robotic and Prosthetic Devices , 2008, Computer.

[34]  Hoi Lee,et al.  A 9-Bit configurable current source with enhanced output resistance for cochlear stimulators , 2008, 2008 IEEE Custom Integrated Circuits Conference.

[35]  Andreas Demosthenous,et al.  An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[36]  Andrew S. Whitford,et al.  Cortical control of a prosthetic arm for self-feeding , 2008, Nature.

[37]  M. Ghovanloo,et al.  Using Pulse Width Modulation for Wireless Transmission of Neural Signals in Multichannel Neural Recording Systems , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[38]  Jose M. Carmena,et al.  A System for Neural Recording and Closed-Loop Intracortical Microstimulation in Awake Rodents , 2009, IEEE Transactions on Biomedical Engineering.

[39]  Reid R. Harrison,et al.  A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[40]  Zhi Yang,et al.  A biomedical multiprocessor SoC for closed-loop neuroprosthetic applications , 2009, 2009 IEEE International Solid-State Circuits Conference - Digest of Technical Papers.

[41]  W. Liu,et al.  A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[42]  Ying Yao,et al.  An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording , 2009, IEEE Journal of Solid-State Circuits.

[43]  Mohsen Mollazadeh,et al.  Micropower CMOS Integrated Low-Noise Amplification, Filtering, and Digitization of Multimodal Neuropotentials , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[44]  Pedram Mohseni,et al.  An activity-dependent brain microstimulation SoC with integrated 23nV/rtHz neural recording front-end and 750nW spike discrimination processor , 2010, 2010 Symposium on VLSI Circuits.

[45]  Karim Abdelhalim,et al.  The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[46]  Michael P. Flynn,et al.  A 64 Channel Programmable Closed-Loop Neurostimulator With 8 Channel Neural Amplifier and Logarithmic ADC , 2010, IEEE Journal of Solid-State Circuits.

[47]  Hillel J. Chiel,et al.  VLSI implementation of a template subtraction algorithm for real-time stimulus artifact rejection , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[48]  Maurits Ortmanns,et al.  An Active Approach for Charge Balancing in Functional Electrical Stimulation , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[49]  John J. Granacki,et al.  Restoring Lost Cognitive Function Hippocampal-Cortical Neural Prostheses , 2022 .