Comparison between a sequencing batch membrane bioreactor and a conventional membrane bioreactor

Abstract An operation of a membrane bioreactor in sequencing batch mode named a sequencing batch membrane bioreactor (SBMBR) was investigated for enhancing nitrogen and phosphorus removal. Its performance was compared with a conventional membrane bioreactor (CMBR) at various influent COD/TN ratios of 3.4–28.2. The operational parameters were optimized to increase the treatment efficiency. COD removal averaged at 94.9 and 97.7%, respectively, for SBMBR and CMBR during the 8 months experimental period. The SBMBR system demonstrated good performance on nitrogen and phosphorus removal at different COD/TN ratios. When COD/TN was 6.3 and the total nitrogen (TN) load was 0.22 kg/(m 3  days), the TN and ammonium nitrogen removals of the SBMBR were maintained over 65 and 90%, respectively. Total phosphorus (TP) removal of the SBMBR was approximately 90% during most of the experimental time. In comparison, the CMBR did not perform so well. Its effluent TN concentration was close to that in the influent at COD/TN = 6.3 and TP removal was not stable. The specific nitrification rate test showed that pH value affected the activity of nitrifiers but no irreversible harm was induced. Furthermore, the sequencing batch mode operation of MBR retarded membrane fouling according to the monitoring of trans-membrane pressure (TMP).

[1]  K. Ahn,et al.  Treatment of household wastewater using an intermittently aerated membrane bioreactor , 1999 .

[2]  A. E. Greenberg,et al.  Standard methods for the examination of water and wastewater : supplement to the sixteenth edition , 1988 .

[3]  H. W. van Verseveld,et al.  Aerobic domestic waste water treatment in a pilot plant with complete sludge retention by cross-flow filtration , 1995 .

[4]  Kazuo Yamamoto,et al.  Household Membrane Bioreactor in Domestic Wastewater Treatment , 1993 .

[5]  A. Konopka,et al.  Biodegradation of organic wastes containing surfactants in a biomass recycle reactor , 1996, Applied and environmental microbiology.

[6]  J. Keller,et al.  Study of factors affecting simultaneous nitrification and denitrification (SND) , 1999 .

[7]  Say Leong Ong,et al.  Study on a sequencing batch membrane bioreactor for wastewater treatment , 2000 .

[8]  P. N. Mishra,et al.  Membrane biological reactor system for treatment of oily wastewaters , 1994 .

[9]  S. Han,et al.  Membrane sequencing batch reactor system for the treatment of dairy industry wastewater , 2003 .

[10]  Nazim Cicek,et al.  Effectiveness of the membrane bioreactor in the biodegradation of high molecular weight compounds , 1998 .

[11]  Kazuo Yamamoto,et al.  Direct Solid-Liquid Separation Using Hollow Fiber Membrane in an Activated Sludge Aeration Tank , 1989 .

[12]  P. Bishop,et al.  Comparison of extraction methods for quantifying extracellular polymers in biofilms , 1999 .

[13]  J Krampe,et al.  Sequencing batch reactor with submerged hollow fibre membranes for the biomass separation. , 2001, Water science and technology : a journal of the International Association on Water Pollution Research.

[14]  A. Konopka,et al.  Thermophilic aerobic treatment of a synthetic wastewater in a membrane-coupled bioreactor , 2001, Journal of Industrial Microbiology and Biotechnology.

[15]  In-Soung Chang,et al.  Membrane filtration characteristics in membrane-coupled activated sludge system -- the effect of physiological states of activated sludge on membrane fouling , 1998 .

[16]  K. Hata,et al.  Domestic wastewater treatment by a submerged membrane bioreactor with gravitational filtration , 1999 .

[17]  S. Yamanishi,et al.  Modeling of biofouling by extracellular polymers in a membrane separation activated sludge system , 1998 .

[18]  Kazuo Yamamoto,et al.  Performance of membrane separation bioreactor at various temperatures for domestic wastewater treatment , 1994 .

[19]  Tatsuki Ueda,et al.  Treatment of domestic sewage from rural settlements by a membrane bioreactor , 1996 .

[20]  Jaime Benítez,et al.  Stabilization and dewatering of wastewater using hollow fiber membranes , 1995 .

[21]  Anthony G. Fane,et al.  Fouling transients in nominally sub-critical flux operation of a membrane bioreactor , 2002 .