Accuracy of implant placement with a stereolithographic surgical guide.

PURPOSE Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic (CT) scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. However, comparison of these advanced techniques to traditional surgical guides has not been performed. The goal of this study was to compare the accuracy of a conventional surgical guide to that of a stereolithographic surgical guide. MATERIALS AND METHODS CT scanning of epoxy edentulous mandibles was performed using a cone beam CT scanner with high isotropic spatial resolution, while planning for 5 implants on each side of the jaw was performed using a commercially available software package. Five surgeons performed osteotomies on a jaw identical to the initial model; on the right side a conventional surgical guide (control side) was used, and on the left side a stereolithographic guide was used (test side). Each jaw was then CT scanned, and a registration method was applied to match it to the initial planning. Measurements included distances between planned implants and actual osteotomies. RESULTS The average distance between the planned implant and the actual osteotomy was 1.5 mm at the entrance and 2.1 mm at the apex when the control guide was used. The same measurements were significantly reduced to 0.9 mm and 1.0 mm when the test guide was used. Variations were also reduced with the test guide, within surgeons and between surgeons. DISCUSSION Surgical guidance for implant placement relieves the clinician from multiple perioperative decisions. Precise implant placement is under investigation using sophisticated guidance methods, including CAD/CAM templates. CONCLUSION Within the limits of this study, implant placement was improved by using a stereolithographic surgical guide.

[1]  D A Tyndall,et al.  Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology. , 2000, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[2]  A. C. Richardson,et al.  The accuracy of dental radiographic techniques used for evaluation of implant fixture placement. , 1995, The International journal of periodontics & restorative dentistry.

[3]  C. Gamble,et al.  Bone classification: an objective scale of bone density using the computerized tomography scan. , 2001, Clinical oral implants research.

[4]  A Petersson,et al.  Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography. , 1989, The International journal of oral & maxillofacial implants.

[5]  Guy Marchal,et al.  An image-guided planning system for endosseous oral implants , 1998, IEEE Transactions on Medical Imaging.

[6]  M W Vannier,et al.  Validation of spiral computed tomography for dental implants. , 1998, Dento maxillo facial radiology.

[7]  R A Kraut,et al.  UTILIZATION OF 3D/DENTAL SOFTWARE FOR PRECISE IMPLANT SITE SELECTION: CLINICAL REPORTS , 1992, Implant dentistry.

[8]  B Rangert,et al.  Forces and moments on Branemark implants. , 1989, The International journal of oral & maxillofacial implants.

[9]  M L McAllister Application of stereolithography to subperiosteal implant manufacture. , 1998, The Journal of oral implantology.

[10]  H Israelson,et al.  Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients. , 1992, The International journal of periodontics & restorative dentistry.

[11]  M W Vannier,et al.  2-D and 3-D reconstructions of spiral computed tomography in localization of the inferior alveolar canal for dental implants. , 1999, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[12]  A N Cranin,et al.  An in vitro comparison of the computerized tomography/CAD-CAM and direct bone impression techniques for subperiosteal implant model generation. , 1998, The Journal of oral implantology.

[13]  M Abrams,et al.  Computer-guided surgery utilizing a computer-milled surgical template. , 2001, Practical procedures & aesthetic dentistry : PPAD.

[14]  M Naitoh,et al.  Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? , 2000, Clinical oral implants research.

[15]  J. Y. Choi,et al.  Analysis of errors in medical rapid prototyping models. , 2002, International journal of oral and maxillofacial surgery.

[16]  K H Thunthy,et al.  Radiographic/surgical template incorporating metal telescopic tubes for accurate implant placement. , 1998, Practical periodontics and aesthetic dentistry : PPAD.

[17]  D M Almog,et al.  Computer Intuition: Guiding Scientific Research in Imaging and Oral Implantology , 1997, Journal of dental research.

[18]  D. Bandy,et al.  CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery , 1989 .

[19]  Richter Ej Basic biomechanics of dental implants in prosthetic dentistry , 1989 .

[20]  Carsten Thomas,et al.  Optical data acquisition for computer-assisted design of facial prostheses. , 2002, The International journal of prosthodontics.

[21]  R Jacobs,et al.  Predictability of reformatted computed tomography for pre-operative planning of endosseous implants. , 1999, Dento maxillo facial radiology.

[22]  R Jacobs,et al.  Predictability of a three-dimensional planning system for oral implant surgery. , 1999, Dento maxillo facial radiology.

[23]  D M Erickson,et al.  An opinion survey of reported benefits from the use of stereolithographic models. , 1999, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[24]  A. Gahleitner,et al.  Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complications during implant surgery. , 2001, The International journal of oral & maxillofacial implants.

[25]  M K Jeffcoat,et al.  Digital radiology for implant treatment planning and evaluation. , 1992, Dento maxillo facial radiology.

[26]  G. Santler,et al.  Indications and limitations of three-dimensional models in cranio-maxillofacial surgery. , 1998, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[27]  M. Çehreli,et al.  Fabrication of a dual-purpose surgical template for correct labiopalatal positioning of dental implants. , 2000, The International journal of oral & maxillofacial implants.

[28]  Basten Ch,et al.  The use of radiopaque templates for predictable implant placement. , 1995 .

[29]  C E Besimo,et al.  Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. , 2000, Dento maxillo facial radiology.

[30]  L. Andersson,et al.  CT scan prior to installation of osseointegrated implants in the maxilla. , 1987, International journal of oral and maxillofacial surgery.

[31]  A N Cranin,et al.  A computerized tomography (CT) scan appliance for optimal presurgical and preprosthetic planning of the implant patient. , 1993, Practical periodontics and aesthetic dentistry : PPAD.

[32]  M S Schwarz,et al.  CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery. Work in progress. , 1988, Radiology.

[33]  Tomas Albrektsson,et al.  Osseointegrated Oral implants , 1988 .

[34]  Franz Kainberger,et al.  Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. , 2002, Clinical oral implants research.

[35]  A L Baert,et al.  CT scan standard reconstruction technique for reliable jaw bone volume determination. , 1990, The International journal of oral & maxillofacial implants.

[36]  Paul F. Jacobs,et al.  Rapid Prototyping & Manufacturing: Fundamentals of Stereolithography , 1992 .

[37]  P Suetens,et al.  Computer-assisted planning of oral implant surgery: a three-dimensional approach. , 1996, The International journal of oral & maxillofacial implants.

[38]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.

[39]  J C Kois,et al.  The use of barium sulfate for implant templates. , 1996, The Journal of prosthetic dentistry.

[40]  M. Jeffcoat,et al.  A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants. , 1994, Clinical oral implants research.

[41]  A. C. Richardson,et al.  Interpretation of linear and computed tomograms in the assessment of implant recipient sites. , 1993, Journal of periodontology.

[42]  J. Fiorellini,et al.  The use of replicate resin models in the treatment of maxillary sinus augmentation patients. , 1997, The International journal of periodontics & restorative dentistry.

[43]  A. Gebhardt,et al.  Custom-made cast titanium implants produced with CAD/CAM for the reconstruction of cranium defects. , 1998, International journal of oral and maxillofacial surgery.