Rat brain imaging using full field optical coherence microscopy with short multimode fiber probe

We demonstrated FF OCM(full field optical coherence microscopy) using an ultrathin forward-imaging SMMF (short multimode fiber) probe of 50 μm core diameter, 125 μm diameter, and 7.4 mm length, which is a typical graded-index multimode fiber for optical communications. The axial resolution was measured to be 2.20 μm, which is close to the calculated axial resolution of 2.06 μm. The lateral resolution was evaluated to be 4.38 μm using a test pattern. Assuming that the FWHM of the contrast is the DOF (depth of focus), the DOF of the signal is obtained at 36 μm and that of the OCM is 66 μm. The contrast of the OCT images was 6.1 times higher than that of the signal images due to the coherence gate. After an euthanasia the rat brain was resected and cut at 2.6mm tail from Bregma. Contacting SMMF to the primary somatosensory cortex and the agranular insular cortex of ex vivo brain, OCM images of the brain were measured 100 times with 2μm step. 3D OCM images of the brain were measured, and internal structure information was obtained. The feasibility of an SMMF as an ultrathin forward-imaging probe in full-field OCM has been demonstrated.

[1]  Izumi Nishidate,et al.  Reflectance Imaging by Graded-Index Short Multimode Fiber , 2013 .

[2]  Antoine Federici,et al.  Wide-field, full-field optical coherence microscopy for high-axial-resolution phase and amplitude imaging. , 2015, Applied optics.

[3]  Sucbei Moon,et al.  Ultra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber. , 2015, Biomedical optics express.

[4]  Jin-Hui Shen,et al.  Miniature real-time intraoperative forward-imaging optical coherence tomography probe. , 2013, Biomedical optics express.

[5]  Emily J. McDowell,et al.  Methods and application areas of endoscopic optical coherence tomography. , 2006, Journal of biomedical optics.

[6]  Michael W. Jenkins,et al.  Fiber-optic catheter-based polarization-sensitive OCT for radio-frequency ablation monitoring. , 2014, Optics letters.

[7]  Xiaoyong Fu,et al.  Miniature forward-viewing common-path OCT probe for imaging the renal pelvis. , 2015, Biomedical optics express.

[8]  Antoine Federici,et al.  Full-field optical coherence microscopy with optimized ultrahigh spatial resolution. , 2015, Optics letters.

[9]  Izumi Nishidate,et al.  Imaging characteristics of an 8.8  mm long and 125  μm thick graded-index short multimode fiber probe. , 2016, Applied optics.

[10]  T. Yatagai,et al.  Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments. , 2005, Optics express.

[11]  Zahid Yaqoob,et al.  Paired-angle-rotation scanning optical coherence tomography forward-imaging probe. , 2006, Optics letters.

[12]  B. Bouma,et al.  Handbook of Optical Coherence Tomography , 2001 .

[13]  Cha-Min Tang,et al.  A forward-imaging needle-type OCT probe for image guided stereotactic procedures , 2011, Optics express.

[14]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[15]  David D Sampson,et al.  Imaging deep skeletal muscle structure using a high-sensitivity ultrathin side-viewing optical coherence tomography needle probe. , 2013, Biomedical optics express.

[16]  Ruo Yu Gu,et al.  Resolution limits for imaging through multi-mode fiber. , 2013, Optics express.

[17]  Izumi Nishidate,et al.  Modulation transfer function of the imaging probe using an 8.8 mm-long and 125 µm-thick graded- index short multimode fiber , 2017 .

[18]  J. Fujimoto,et al.  Imaging needle for optical coherence tomography. , 2000, Optics letters.

[19]  Govind P. Agrawal,et al.  Nonlinear Fiber Optics , 1989 .

[20]  J. C. Lodder,et al.  Volumetric Imaging and Quantification of Cytoarchitecture and Myeloarchitecture with Intrinsic Scattering Contrast References and Links , 2022 .

[21]  A. Boccara,et al.  High-resolution full-field optical coherence tomography with a Linnik microscope. , 2002, Applied optics.

[22]  T. Chomiak,et al.  What Is the Optimal Value of the g-Ratio for Myelinated Fibers in the Rat CNS? A Theoretical Approach , 2009, PloS one.

[23]  V. Srinivasan,et al.  Optical coherence microscopy for deep tissue imaging of the cerebral cortex with intrinsic contrast , 2012, Optics express.

[24]  B. Messerschmidt,et al.  Fabrication tolerances and metrology requirements for ion-exchanged micro-optic lenses: What's good enough? , 1997, Applied optics.

[25]  S. Gigan,et al.  Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy. , 2011, Optics express.

[26]  W. Marsden I and J , 2012 .

[27]  Ki-Hun Jeong,et al.  Forward imaging OCT endoscopic catheter based on MEMS lens scanning. , 2012, Optics letters.

[29]  J. Fujimoto,et al.  Optical coherence microscopy in scattering media. , 1994, Optics letters.

[30]  K. Okamoto Fundamentals of Optical Waveguides , 2000 .

[31]  Egidijus Auksorius,et al.  Dark-field full-field optical coherence tomography. , 2015, Optics letters.

[32]  Justin Pedro,et al.  Multidimensional en-face OCT imaging of the retina. , 2009, Optics express.

[33]  D. Jackson,et al.  Simultaneous en-face imaging of two layers in the human retina by low-coherence reflectometry. , 1997, Optics letters.

[34]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[35]  R. Garman,et al.  Histology of the Central Nervous System , 2011, Toxicologic pathology.

[36]  Shoude Chang,et al.  Graded-index fiber lens proposed for ultrasmall probes used in biomedical imaging. , 2007, Applied optics.

[37]  Fabrice Harms,et al.  Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by interferometric signals temporal analysis. , 2016, Biomedical optics express.

[38]  Xingde Li,et al.  Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography. , 2004, Optics letters.

[39]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[40]  Mark J Schnitzer,et al.  Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry. , 2002, Optics letters.

[41]  Maciej Wojtkowski,et al.  Extended-focus optical coherence microscopy for high-resolution imaging of the murine brain. , 2016, Biomedical optics express.

[42]  Izumi Nishidate,et al.  Imaging of rat brain using short graded-index multimode fiber , 2014, Photonics West - Biomedical Optics.

[43]  Byeong Ha Lee,et al.  Fiber-based optical coherence tomography for biomedical imaging, sensing, and precision measurements , 2013 .

[44]  B E Bouma,et al.  Spectrally-modulated full-field optical coherence microscopy for ultrahigh-resolution endoscopic imaging. , 2006, Optics express.

[45]  R. Tatam,et al.  Fibre imaging bundles for full-field optical coherence tomography , 2007 .

[46]  Izumi Nishidate,et al.  Ultrathin forward-imaging short multimode fiber probe for full-field optical coherence microscopy , 2016 .

[47]  Takamasa Suzuki,et al.  Multifrequency swept common-path en-face OCT for wide-field measurement of interior surface vibrations in thick biological tissues. , 2015, Optics express.