An integrated platform for small-animal hyperthermia investigations under ultra-high-field MRI guidance

Abstract Purpose: Integrating small-animal experimental hyperthermia instrumentation with magnetic resonance imaging (MRI) affords real-time monitoring of spatial temperature profiles. This study reports on the development and preliminary in vivo characterisation of a 2.45 GHz microwave hyperthermia system for pre-clinical small animal investigations, integrated within a 14 T ultra-high-field MRI scanner. Materials and methods: The presented system incorporates a 3.5 mm (OD) directional microwave hyperthermia antenna, positioned adjacent to the small-animal target, radiating microwave energy for localised heating of subcutaneous tumours. The applicator is integrated within the 30 mm bore of the MRI system. 3D electromagnetic and biothermal simulations were implemented to characterise hyperthermia profiles from the directional microwave antenna. Experiments in tissue mimicking phantoms were performed to assess hyperthermia profiles and validate MR thermometry against fibre-optic temperature measurements. The feasibility of delivering in vivo hyperthermia exposures to subcutaneous 4T1 tumours in experimental mice under simultaneous MR thermometry guidance was assessed. Results: Simulations and experiments in tissue mimicking phantoms demonstrated the feasibility of heating 21–982 mm3 targets with 8–12 W input power. Minimal susceptibility and electrical artefacts introduced by the hyperthermia applicator were observed on MR imaging. MR thermometry was in excellent agreement with fibre-optic temperatures measurements (max. discrepancy ≤0.6 °C). Heating experiments with the reported system demonstrated the feasibility of heating subcutaneous tumours in vivo with simultaneous MR thermometry. Conclusions: A platform for small-animal hyperthermia investigations under ultra-high-field MR thermometry was developed and applied to heating subcutaneous tumours in vivo.

[1]  Ashutosh Kumar Singh,et al.  Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours , 2005, Physics in medicine and biology.

[2]  Dieter Haemmerich,et al.  Mild hyperthermia triggered doxorubicin release from optimized stealth thermosensitive liposomes improves intratumoral drug delivery and efficacy. , 2013, Journal of controlled release : official journal of the Controlled Release Society.

[3]  Thoralf Niendorf,et al.  Magnetic resonance thermometry: Methodology, pitfalls and practical solutions , 2016, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  M. Kuroda,et al.  Thermal enhancement of the effect of ifosfamide against a spontaneous murine fibrosarcoma, FSa-II. , 1997, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[5]  D. Alberts,et al.  Therapeutic synergism of hyperthermia-cis-platinum in a mouse tumor model. , 1980, Journal of the National Cancer Institute.

[6]  Shigehiro Morikawa,et al.  MR‐guided microwave thermocoagulation therapy of liver tumors: Initial clinical experiences using a 0.5 T open MR system , 2002, Journal of magnetic resonance imaging : JMRI.

[7]  A. Eggermont,et al.  Hyperthermia and Thermosensitive Liposomes for Improved Delivery of Chemotherapeutic Drugs to Solid Tumors , 2010, Pharmaceutical Research.

[8]  M. Peller,et al.  Method of hyperthermia and tumor size influence effectiveness of doxorubicin release from thermosensitive liposomes in experimental tumors. , 2016, Journal of controlled release : official journal of the Controlled Release Society.

[9]  Punit Prakash,et al.  A Directional Interstitial Antenna for Microwave Tissue Ablation: Theoretical and Experimental Investigation , 2015, IEEE Transactions on Biomedical Engineering.

[10]  M. Dewhirst,et al.  The future of biology in driving the field of hyperthermia , 2016, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  S. Calderwood Hyperthermia, the Tumor Microenvironment and Immunity , 2013 .

[12]  B. Wood,et al.  Temperature-sensitive liposome-mediated delivery of thrombolytic agents , 2015, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[13]  Camelia Gabriel,et al.  Dielectric parameters relevant to microwave dielectric heating , 1998 .

[14]  Chris J. Diederich,et al.  Magnetic Resonance-Guided High-Intensity Ultrasound Ablation of the Prostate , 2006, Topics in magnetic resonance imaging : TMRI.

[15]  G. Allan Johnson,et al.  Modern Trends in Imaging VII: Magnetic Resonance Microscopy , 2011, Analytical cellular pathology.

[16]  Zeljko Vujaskovic,et al.  Re-setting the biologic rationale for thermal therapy , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[17]  B. Ruggeri,et al.  Animal models of disease: pre-clinical animal models of cancer and their applications and utility in drug discovery. , 2014, Biochemical pharmacology.

[18]  J. van der Zee,et al.  Practical limitations of interstitial thermometry during deep hyperthermia. , 1998, International journal of radiation oncology, biology, physics.

[19]  Robert E Lenkinski,et al.  Radiofrequency ablation: importance of background tissue electrical conductivity--an agar phantom and computer modeling study. , 2005, Radiology.

[20]  M. Dewhirst,et al.  Miniature microwave applicator for murine bladder hyperthermia studies , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[21]  C. Balanis Advanced Engineering Electromagnetics , 1989 .

[22]  Rajiv Chopra,et al.  Targeted antibiotic delivery using low temperature-sensitive liposomes and magnetic resonance-guided high-intensity focused ultrasound hyperthermia , 2016, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[23]  Christopher L Brace,et al.  Principles of and advances in percutaneous ablation. , 2011, Radiology.

[24]  S. Gabriel,et al.  Dielectric parameters relevant to microwave dielectric heating , 1998 .

[25]  A. W. Simonetti,et al.  Tumour hyperthermia and ablation in rats using a clinical MR‐HIFU system equipped with a dedicated small animal set‐up , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[26]  Sergio Silvestri,et al.  CT-based thermometry: An overview , 2014, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[27]  Alexandru Cernicanu,et al.  Validation of fast MR thermometry at 1.5 T with gradient‐echo echo planar imaging sequences: phantom and clinical feasibility studies , 2008, NMR in biomedicine.

[28]  J. Fütterer,et al.  Development of a high-field MR-guided HIFU setup for thermal and mechanical ablation methods in small animals , 2015, Journal of therapeutic ultrasound.

[29]  Chris J Diederich,et al.  Effects of spatial and temporal resolution for MR image‐guided thermal ablation of prostate with transurethral ultrasound , 2005, Journal of magnetic resonance imaging : JMRI.

[30]  Rajiv Chopra,et al.  Thermometry and ablation monitoring with ultrasound , 2015, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[31]  S. Combs,et al.  Rationale of hyperthermia for radio(chemo)therapy and immune responses in patients with bladder cancer: Biological concepts, clinical data, interdisciplinary treatment decisions and biological tumour imaging , 2016, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[32]  Dieter Haemmerich,et al.  Targeted drug delivery by high intensity focused ultrasound mediated hyperthermia combined with temperature-sensitive liposomes: Computational modelling and preliminary in vivovalidation , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[33]  John M Pauly,et al.  Referenceless PRF shift thermometry , 2004, Magnetic resonance in medicine.

[34]  J. James,et al.  Controlled radio-frequency hyperthermia using an MR scanner and simultaneous monitoring of temperature and therapy response by 1H, 23Na and 31P magnetic resonance spectroscopy in subcutaneously implanted 9L-gliosarcoma , 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[35]  E. Dumont,et al.  Magnetic Resonance Thermometry at 7T for Real-Time Monitoring and Correction of Ultrasound Induced Mild Hyperthermia , 2012, PloS one.

[36]  David L. Woods,et al.  Mild hyperthermia with magnetic resonance-guided high-intensity focused ultrasound for applications in drug delivery , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[37]  Rajiv Chopra,et al.  Localised hyperthermia in rodent models using an MRI-compatible high-intensity focused ultrasound system , 2015, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[38]  Rajiv Chopra,et al.  An MRI-compatible system for focused ultrasound experiments in small animal models. , 2009, Medical physics.

[39]  Rajiv Chopra,et al.  MR thermometry in the human prostate gland at 3.0T for transurethral ultrasound therapy , 2013, Journal of magnetic resonance imaging : JMRI.

[40]  Thoralf Niendorf,et al.  Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla , 2013, PloS one.

[41]  Jan Vrba,et al.  Microwave applicator for hyperthermia treatment on in vivo melanoma model , 2010, Medical & Biological Engineering & Computing.

[42]  E. Moros,et al.  An alternating focused ultrasound system for thermal therapy studies in small animals. , 2011, Medical physics.