The Error in Variables (EIV) Regression Approach as a Means of Identifying Unbiased Physical Parameter Estimates: Application to Chiller Performance Data

Classical linear regression analysis by the method of Ordinary Least Squares (OLS) considers errors to affect the dependent variable only, while it is implicitly assumed that the independent or regressor variables are free of error. This assumption is frequently unrealistic, because measurement inaccuracies in the regressor variables are sometimes very large. If these variables are correlated, which is often the case, model coefficients identified by OLS will be biased. This issue may be of secondary concern if the model is used for predictive purposes only, but it is problematic if the model coefficients are to be interpreted as physical quantities and used for diagnostic purposes. A modeling approach that can overcome this deficiency is the Error-InVariable (EIV) regression approach, which can provide unbiased parameter estimates even in the presence of errors in the regressor variables (under the assumption that the errors are unbiased and normally distributed) and when the regressor variables are correlated. This paper describes this method, and, based on precise chiller performance data measured in a laboratory, illustrates the benefit and advantage of the EIV method over the OLS method in the framework of the Gordon and Ng (GN) chiller model. It is found that biased parameter estimates are very likely to occur when OLS is used for identification using the GN model even when well-maintained field instrumentation is used. This bias in parameter estimates can be minimized or even eliminated when the EIV method is used instead.

[1]  Hugh W. Coleman,et al.  Experimentation and Uncertainty Analysis for Engineers , 1989 .

[2]  G. Casella,et al.  Statistical Inference , 2003, Encyclopedia of Social Network Analysis and Mining.

[3]  Wayne A. Fuller,et al.  Statistical analysis of measurement error models and applications : proceedings of the AMS-IMS-SIAM Joint Summer Research conference held June 10-16, 1989, with support from the National Science Foundation and the U.S. Army Research Office , 1990 .

[4]  Sabine Van Huffel,et al.  Total least squares problem - computational aspects and analysis , 1991, Frontiers in applied mathematics.

[5]  S. Chatterjee,et al.  Regression Analysis by Example (2nd ed.). , 1992 .

[6]  S. Chatterjee,et al.  Regression Analysis by Example , 1979 .

[7]  Jeffrey M. Gordon,et al.  Thermodynamic modeling of reciprocating chillers , 1994 .

[8]  K. Ng,et al.  Predictive and diagnostic aspects of a universal thermodynamic model for chillers , 1995 .

[9]  J. Klein Woud,et al.  On-line failure diagnosis for compression refrigeration plants , 1995 .

[10]  Philip Haves,et al.  Condition monitoring in HVAC subsystems using first principles models , 1996 .

[11]  C. Park,et al.  Fault detection in an air-handling unit using residual and recursive parameter identification methods , 1996 .

[12]  Anthony C. Davison,et al.  Bootstrap Methods and Their Application , 1998 .

[13]  Todd M. Rossi,et al.  A Statistical, Rule-Based Fault Detection and Diagnostic Method for Vapor Compression Air Conditioners , 1997 .

[14]  Jeffrey M. Gordon,et al.  Diagnostics and optimization of reciprocating chillers: theory and experiment , 1997 .

[15]  Janos Gertler,et al.  Fault detection and diagnosis in engineering systems , 1998 .

[16]  Jie Chen,et al.  Robust Model-Based Fault Diagnosis for Dynamic Systems , 1998, The International Series on Asian Studies in Computer and Information Science.

[17]  Sami Karjalainen,et al.  Performance factors as a basis of practical fault detection and diagnostic methods for air-handling units , 1999 .

[18]  C. Y. Han,et al.  Fault detection and diagnosis of HVAC systems , 1999 .

[19]  Tony L. Wahl,et al.  Experimentation and Uncertainty Analysis for Engineers, 2nd Ed. , 1999 .

[20]  Frederick W. Faltin,et al.  Statistical Control by Monitoring and Feedback Adjustment , 1999, Technometrics.

[21]  Richard F. Gunst,et al.  Applied Regression Analysis , 1999, Technometrics.

[22]  Jeffrey M. Gordon,et al.  How varying condenser coolant flow rate affects chiller performance: thermodynamic modeling and experimental confirmation , 2000 .

[23]  Terri L. Moore,et al.  Regression Analysis by Example , 2001, Technometrics.

[24]  T. Agami Reddy,et al.  An Evaluation of Classical Steady-State Off-Line Linear Parameter Estimation Methods Applied to Chiller Performance Data , 2002 .