Design of a New Instrumented Forceps: Application to Safe Obstetrical Forceps Blade Placement

Today, medical simulators are increasingly gaining appeal in clinical settings. In obstetrics childbirth simulators provide a training and research tool for comparing various techniques that use obstetrical instruments or validating new methods. Especially in the case of difficult deliveries, the use of obstetrical instruments - such as forceps, spatulas, and vacuum extractors - has become essential. However, such instruments increase the risk of injury to both the mother and fetus. Only clinical experience acquired in the delivery room enables health professionals to reduce this risk. In this context, we have developed, in collaboration with researchers and physicians, a new type of instrumented forceps that offers new solutions for training obstetricians in the safe performance of forceps deliveries. This paper focuses on the design of this instrumented forceps, coupled with the BirthSIM simulator. This instrumented forceps allows to study its displacement inside the maternal pelvis. Methods for analyzing the operator repeatability and to compare forceps blade placements to a reference one are developed. The results highlight the need of teaching tools to adequately train novice obstetricians.

[1]  A R FLEMING,et al.  Introduction of a metric forceps; preliminary report. , 1959, American journal of obstetrics and gynecology.

[2]  Moolgaoker As,et al.  A comparison of different methods of instrumental delivery based on electronic measurements of compression and traction. , 1979 .

[3]  D A Nagey,et al.  Simulating birth to investigate clinician-applied loads on newborns. , 1995, Medical engineering & physics.

[4]  Robert Riener,et al.  An Augmented Reality Delivery Simulator for Medical Training , 2004 .

[5]  Blake Hannaford,et al.  Biomedical Paper Task Decomposition of Laparoscopic Surgery for Objective Evaluation of Surgical Residents' Learning Curve Using Hidden Markov Model , 2002 .

[6]  C N Hudson,et al.  Anal-sphincter disruption during vaginal delivery. , 1993, The New England journal of medicine.

[7]  Burdett Wylie,et al.  Traction in Forceps Deliveries , 1935 .

[8]  O. Dupuis,et al.  Apport du forceps instrumenté dans la sécurité de l'extraction instrumentale , 2005 .

[9]  B. Hannaford,et al.  Task decomposition of laparoscopic surgery for objective evaluation of surgical residents' learning curve using hidden Markov model. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[10]  E.J. Kim,et al.  Simulating complicated human birth for research and training , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  P. Vieyres,et al.  Kinematics of a dedicated 6DOF Robot for Tele-echography , 2003 .

[12]  Tanneguy Redarce,et al.  Extraction instrumentale en 2002 au sein du réseau AURORE : incidence et complications néo-natales graves , 2003 .

[13]  Tanneguy Redarce,et al.  A new mechanical birth simulator: BirthSIM , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[14]  A MOOLGAOKER,et al.  A NEW DESIGN OF OBSTETRIC FORCEPS , 1962, The Journal of obstetrics and gynaecology of the British Empire.

[15]  Robert Riener,et al.  Geburtensimulator mit multimodaler Interaktion (Delivery Simulator with Multimodal Interaction) , 2004 .

[16]  P. R. Payne,et al.  A Comparison of Different Methods of Instrumental Delivery Based on Electronic Measurements of Compression and Traction , 1979, Obstetrics and gynecology.

[17]  Blake Hannaford,et al.  The BlueDRAGON - a system for measuring the kinematics and dynamics of minimally invasive surgical tools in-vivo , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[18]  Tanneguy Redarce,et al.  A new obstetric forceps for the training of junior doctors: a comparison of the spatial dispersion of forceps blade trajectories between junior and senior obstetricians. , 2006, American journal of obstetrics and gynecology.

[19]  Rudy J. Lapeer,et al.  An augmented reality based simulation of obstetric forceps delivery , 2004, Third IEEE and ACM International Symposium on Mixed and Augmented Reality.

[20]  Agnès Guerraz,et al.  Etude du télégeste médical non invasif utilisant un transducteur gestuel à retour d'efforts. (Study of the noninvasive medical tele-gesture using a haptic device) , 2002 .

[21]  Jean-Daniel Boissonnat,et al.  3D simulation of delivery , 1993, Proceedings Visualization '93.

[22]  P ROSA [In defense of suction grip extraction]. , 1955, Bruxelles medical.

[23]  L. Kozak,et al.  U.S. trends in obstetric procedures, 1990-2000. , 2002, Birth.

[24]  Shahram Payandeh,et al.  Task and Motion Analyses in Endoscopic Surgery , 1996, Dynamic Systems and Control.

[25]  Christian Duriez,et al.  Preliminary design of a childbirth simulator haptic feedback , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[26]  G Sines,et al.  An assessment of the compression and traction forces of obstetrical forceps. , 1966, American journal of obstetrics and gynecology.

[27]  Tanneguy Redarce,et al.  Birth simulator: reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification. , 2005, American journal of obstetrics and gynecology.

[28]  Etienne Dombre,et al.  Robotized reconstructive surgery: ongoing study and first results , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[29]  Ruimark Creazzola Silveira Modélisation et conception d'un nouveau simulateur d'accouchement (BirthSIM) pour l'entraînement et l'enseignement des jeunes obstétriciens et des sages-femmes , 2004 .

[30]  P. J. Fleming,et al.  Genetic Algorithms in Control Systems Engineering , 1993 .