Synthetic CT: simulating arbitrary low dose single and dual energy protocols

CT protocol selection (kVp, mAs, filtration) can greatly affect the dose delivered to a patient and the quality of the resulting images. While it is imperative to get diagnostic quality images from a study, the dose to the patient should be minimized. With synthetic CT, protocol optimization is made simple by simulating realistic scans of arbitrary low dose protocols from a previously acquired dual energy scan. For single energy protocols, the simulated projections have the same statistical properties as projections from an actual scan. The reconstruction of these synthesized projections then provides realistic images at a different protocol. For dual energy protocols, the material decomposition of the simulated protocol is directly synthesized. Moreover, the dose distribution from an arbitrary protocol (single or dual energy) can be found and used in conjunction with the predicted image quality for protocol design. We demonstrate single energy synthetic CT on a clinical study by synthesizing a 120 kVp image from a dual energy dataset. The synthesized image is compared to an actual 120 kVp image on the same patient, showing excellent agreement. We also describe a framework for implementing synthetic CT in software that is intuitive to use and allows radiologists to see the impact of protocol selection on image quality and dose distribution. A simple GUI demonstrates the vision for synthetic CT by allowing for the comparison of several dose reduction techniques: filtration, mA modulation, partial scan, or shielding. In particular, objects such as a breast shield can be simulated and virtually inserted as part of the original scan. In each case, the kVp and mAs can be adjusted while the synthesized image and dose profile are updated in real-time. With such software, synthetic CT can be applied as an educational and scientific tool for radiologists concerned with dose and image quality.

[1]  Jiang Hsieh,et al.  Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. , 2002, AJR. American journal of roentgenology.

[2]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[3]  Norbert J. Pelc,et al.  Sufficient Statistics as a Generalization of Binning in Spectral X-ray Imaging , 2011, IEEE Transactions on Medical Imaging.

[4]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[5]  G T Barnes,et al.  Detector for dual-energy digital radiography. , 1985, Radiology.

[6]  F. Verhaegen,et al.  Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations , 2008, Physics in medicine and biology.

[7]  Sue C. Kaste,et al.  The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients—a white paper executive summary , 2006, Pediatric Radiology.

[8]  Dan Xu,et al.  Dual energy CT via fast kVp switching spectrum estimation , 2009, Medical Imaging.

[9]  Claude Nahmias,et al.  Radiation Risk to Children From Computed Tomography , 2008, Pediatrics.

[10]  C. McCollough,et al.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration. , 2009, Medical physics.

[11]  A. Leung,et al.  Simulated dose reduction in conventional chest CT: validation study. , 1997, Radiology.

[12]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[13]  T. Slovis,et al.  Children, computed tomography radiation dose, and the As Low As Reasonably Achievable (ALARA) concept. , 2003, Pediatrics.

[14]  Adam S Wang,et al.  Synthetic CT: simulating low dose single and dual energy protocols from a dual energy scan. , 2011, Medical physics.

[15]  A. Macovski,et al.  Generalized image combinations in dual KVP digital radiography. , 1981, Medical physics.

[16]  F. M. Vos,et al.  CT colonography: feasibility of substantial dose reduction--comparison of medium to very low doses in identical patients. , 2004, Radiology.

[17]  K. Strauss,et al.  The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients--a white paper executive summary. , 2006, Radiology.

[18]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[19]  E. Roessl,et al.  On the influence of noise correlations in measurement data on basis image noise in dual-energylike x-ray imaging. , 2007, Medical physics.

[20]  Willi A. Kalender,et al.  Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations , 2008, European Radiology.

[21]  Donald P Frush,et al.  In-plane bismuth breast shields for pediatric CT: effects on radiation dose and image quality using experimental and clinical data. , 2003, AJR. American journal of roentgenology.

[22]  J. Geleijns,et al.  Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality , 2006, European Radiology.

[23]  Greta Toncheva,et al.  Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. , 2008, AJR. American journal of roentgenology.

[24]  H. Kauczor,et al.  Radiation dose reduction in chest CT: a review. , 2008, AJR. American journal of roentgenology.

[25]  M. L. R. D. Christenson Air Trapping: Comparison of Standard-Dose and Simulated Low-Dose Thin-Section CT Techniques , 2008 .

[26]  J N Lee,et al.  Synthesized MR images: comparison with acquired images. , 1985, Radiology.