Numerical and experimental thermal analysis for the improvement of various types of windows frames and rolling-shutter boxes

Data provided by Italian Ministry of Environment say that in 5 years you consume, just for heating of an apartment, an amount of energy equal to that required for the all construction of the same apartment. The years come down to three if one includes other energy consumption. In terms of primary energy, the building-plant system is responsible for about 45 % of the national energy demand. The rolling-shutter box system, in most cases, is the first responsible for thermal dispersions and input of free heat coming from outside. In addition, the window frames have the obligation of the CE marking to be sold on the free European market. Among the basic requirements, the thermal transmittance is the parameter responsible for the energy performance. The research concerned the energy study of different window frames and rolling-shutter boxes through the use of finite element methodology and experiments in situ. This study was carried out on six different types of windows frames (PVC, wood, and wood-aluminium) and four different models of rolling shutters-boxes (all with structure made by expanded polystyrene). The experimental analysis allowed the comparison between the thermal transmittance values calculated according to the UNI EN ISO 10077-1/2 and measured in accordance with ISO 9869.

[1]  Mahjoub Elnimeiri,et al.  The effect of geometry factors on fenestration energy performance and energy savings in office buildings , 2013 .

[2]  A. Stegou-Sagia,et al.  The impact of glazing on energy consumption and comfort , 2007 .

[3]  Andrea Gasparella,et al.  Analysis and modelling of window and glazing systems energy performance for a well insulated residential building , 2011 .

[4]  Fabio Bisegna,et al.  Saving energy in residential buildings: The use of fully reversible windows , 2007 .

[5]  Hidayat Shahid,et al.  Energy performance assessment of a window with a horizontal Venetian blind , 2005 .

[6]  Finn Harken Kristiansen,et al.  Super insulating aerogel glazing , 2005 .

[7]  Czeslaw Oleskowicz-Popiel,et al.  Effect of the roller blinds on heat losses through a double-glazing window during heating season in Central Europe , 2014 .

[8]  Cheol-Yong Jang,et al.  Thermal transmittance of window systems and effects on building heating energy use and energy efficiency ratings in South Korea , 2013 .

[9]  H. Manz,et al.  Energy performance of glazings in European climates , 2012 .

[10]  Giorgio Baldinelli,et al.  Influence of cavities geometric and emissivity properties on the overall thermal performance of aluminum frames for windows , 2013 .

[11]  Esam M. Alawadhi,et al.  Using phase change materials in window shutter to reduce the solar heat gain , 2012 .

[12]  Svend Svendsen,et al.  Comparison between ASHRAE and ISO thermal transmittance calculation methods , 2007 .