Safety of MR Scanning in Patients with Nonferromagnetic Aneurysm Clips

The purpose of this study was to report our surveillance of patients with nonferromagnetic aneurysm clips (NFAC) who have undergone magnetic resonance imaging (MRI). Forty‐six patients with NFAC underwent MRI over a 7‐year period. Medical records were studied for evidence of subjective or objective clinical findings as a result of the MRI scan. In two patients with subjective complaints, computed tomograms (CT) were reviewed and patient interviews conducted. No significant neurologic signs or long‐term symptoms were experienced. Two patients did not complete their MRI scans due to transient unilateral head pain in one and head “pressure” in another. CT scans in these patients demonstrated no evidence for hemorrhage or visible change in clip position. We documented no objective adverse outcome of patients undergoing MRI with NFAC, confirming that MRI can be performed safely in patients with nonferromagnetic aneurysm clips. The cause of subjective complaints in two of our patients is unknown. J. Magn. Reson. Imaging 2000;12:198–200. © 2000 Wiley‐Liss, Inc.

[1]  E. Larsson,et al.  Comparison of MR imaging and CT in patients with intracranial aneurysm clips. , 1988, AJNR. American journal of neuroradiology.

[2]  D. Pelz,et al.  MR imaging after surgery for vertebrobasilar aneurysm. , 1990, AJNR. American journal of neuroradiology.

[3]  B. Persson,et al.  Magnetic resonance imaging and aneurysm clips. Magnetic properties and image artifacts. , 1989, Journal of neurosurgery.

[4]  F G Shellock,et al.  High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. , 1988, AJR. American journal of roentgenology.

[5]  R McKinney,et al.  Magnetic field effects on surgical ligation clips. , 1987, Magnetic resonance imaging.

[6]  H. Steiger,et al.  Postoperative spiral computed tomography and magnetic resonance angiography after aneurysm clipping with titanium clips. , 1997, Neurosurgery.

[7]  B. Worthington,et al.  The effects of magnetic resonance imaging on different types of microsurgical clips. , 1985, Journal of neurology, neurosurgery, and psychiatry.

[8]  D G Norris,et al.  Comprehensive regulations concerning exposure of employees to electromagnetic fields. , 1999, Journal of magnetic resonance imaging : JMRI.

[9]  R. Klucznik,et al.  Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with a fatal outcome. , 1993, Radiology.

[10]  J. Lewin,et al.  Aneurysm clip testing for ferromagnetic properties: clip variability issues. , 1997, Radiology.

[11]  R. Ordidge,et al.  Global Call to Action on MR Safety , 1999, Journal of magnetic resonance imaging : JMRI.

[12]  E Kanal,et al.  Aneurysm clips: effects of long-term and multiple exposures to a 1.5-T MR system. , 1999, Radiology.

[13]  M. Dujovny,et al.  Magnetic field gradients in the MRI suite and their effects on aneurysm clips. , 1996, Neurological Research.

[14]  F. Shellock MR imaging of metallic implants and materials: a compilation of the literature. , 1988, AJR. American journal of roentgenology.

[15]  M Dujovny,et al.  Aneurysm clip motion during magnetic resonance imaging: in vivo experimental study with metallurgical factor analysis. , 1985, Neurosurgery.

[16]  K V Slavin,et al.  Magnetic characteristics of Yaşargil aneurysm clips. , 1997, Surgical neurology.

[17]  Magnetic resonance imaging and aneurysm clips. , 1990, Journal of neurosurgery.

[18]  A. Rossier Letter to the Editor , 1986, Paraplegia.

[19]  E Kanal,et al.  Yasargil aneurysm clips: evaluation of interactions with a 1.5-T MR system. , 1998, Radiology.

[20]  E Kanal,et al.  MR imaging of patients with intracranial aneurysm clips. , 1993, Radiology.

[21]  R. Henkelman,et al.  Magnetic resonance imaging and surgical clips. , 1984, Canadian journal of surgery. Journal canadien de chirurgie.