A novel, compact instrument for the measurement and evaluation of relaxation currents conceived for on-site diagnosis of electric power apparatus

Ageing of insulation materials and systems may well be detected by quantitative measurements of their dielectric response. Such measurements can be performed in the frequency or time domain. In this contribution, a novel type of equipment based on relaxation current measurements is introduced which is designed for on-site tests of high voltage power apparatus. The introduction outlines the reasons for the development. Then, the technique of the instrument is briefly explained. Finally, some examples of on-site measurements on power transformers are presented and post-processing and interpretation of the results is demonstrated.

[1]  Vincent E. Manni,et al.  Evaluating Motor Ground Insulation for Improved Operating Reliability , 1978, IEEE Transactions on Industry Applications.

[2]  A. Jonscher Dielectric relaxation in solids , 1983 .

[3]  F. Mopsik,et al.  Precision time‐domain dielectric spectrometer , 1984 .

[4]  李幼升,et al.  Ph , 1989 .

[5]  M. Webb,et al.  Polarisation spectrum analysis for diagnosis of insulation systems , 1992 .

[6]  W. S. Zaengl,et al.  Time domain measurements of dielectric response in oil-paper insulation systems , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[7]  V. Der Houhanessian,et al.  Application of relaxation current measurements to on-site diagnosis of power transformers , 1997, IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[8]  W. Zaengl,et al.  On-site diagnosis of power transformers by means of relaxation current measurements , 1998, Conference Record of the 1998 IEEE International Symposium on Electrical Insulation (Cat. No.98CH36239).

[9]  G. Stone,et al.  Recent developments in diagnostic testing of stator windings , 1998 .

[10]  W. S. Zaengl,et al.  Development and application of new condition assessment methods for power transformers , 1998 .

[11]  M. Krecke,et al.  Dielectric test methods for rotating machine stator insulation inspection , 1998, 1998 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.98CH36257).

[12]  Vahe Der Houhanessian,et al.  Measurement and analysis of dielectric response in oil-paper insulation systems , 1998 .

[13]  E. Ildstad,et al.  Application of dielectric response measurements for condition assessment of service aged XLPE cables , 1999, 1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319).

[14]  A. J. Kachler On-site diagnosis of power and special transformers , 2000, Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075).