On‐Off PVC Membrane Based Potentiometric Immunosensor for Label‐Free Detection of Alpha‐Fetoprotein

A poly(vinylchloride) (PVC) membrane based potentiometric immunosensor for the direct detection of alpha-fetoprotein (AFP) has been developed. First, Au colloid particle was chemisorbed upon amino groups of o-phenylenediamine, which were dissolved in plasticized PVC membrane. Then alpha-fetoprotein antibody (anti-AFP) was immobilized upon the surface of the Au colloid particle to prepare a potentiometric AFP immunosensor. The Au colloid particle modified PVC membrane was characterized by digital photo and transmission electron microscope (TEM). The immunosensor exhibited fast potentiometric response (≤4 min) and showed specific response to AFP in the range of 4.9 to 158.5 ng/mL with a correlation coefficient of 0.9971 and a detection limit of 1.6 ng/mL. The factors influencing the performance of the immunosensor were also studied in detail. Moreover, the proposed method is economical and efficient as well as potentially attractive for clinical immunoassays.

[1]  Ying Zhang,et al.  A new potentiometric immunosensor for determination of α-fetoprotein based on improved gelatin-silver complex film , 2006 .

[2]  Y. Chai,et al.  Electrochemical detection of hepatitis B surface antigen using colloidal gold nanoparticles modified by a sol-gel network interface. , 2006, Clinical biochemistry.

[3]  L. Bolondi,et al.  Tumor doubling time predicts recurrence after surgery and describes the histological pattern of hepatocellular carcinoma on cirrhosis. , 2005, Journal of hepatology.

[4]  Y. Chai,et al.  Potentiometric immunosensor based on antiserum of Japanese B encephalitis immobilized in nano-Au/polymerized o-phenylenediamine film , 2004 .

[5]  A. Riskin,et al.  Alpha-fetoprotein in the early neonatal period--a large study and review of the literature. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[6]  M. Mehrvar,et al.  Recent Developments, Characteristics, and Potential Applications of Electrochemical Biosensors , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[7]  Yan Liu,et al.  Ultrasensitive potentiometric immunosensor based on SA and OCA techniques for immobilization of HBsAb with colloidal Au and polyvinyl butyral as matrixes. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[8]  V. Cherkasov,et al.  An ultrasensitive and stable potentiometric immunosensor. , 2003, Biosensors & bioelectronics.

[9]  T. Katsu,et al.  Thallium(I)-selective membrane electrodes based on calix[6]arene or calix[5]arene derivatives , 2002 .

[10]  M. F. Yulaev,et al.  Development of a potentiometric immunosensor for herbicide simazine and its application for food testing , 2001 .

[11]  Chunliang Feng,et al.  Study on highly sensitive potentiometric IgG immunosensor , 2000 .

[12]  Christopher P. Price,et al.  The Evolution of Immunoassay as Seen Through the Journal Clinical Chemistry , 1998 .

[13]  C P Price,et al.  Immunosensors: technology and opportunities in laboratory medicine. , 1996, Clinical chemistry.

[14]  F V Bright,et al.  Regenerable fiber-optic-based immunosensor. , 1990, Analytical chemistry.

[15]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[16]  J. Janata,et al.  Field effect transistor sensitive to penicillin , 1980 .

[17]  M. Meyerhoff,et al.  Potentiometric enzyme channelling immunosensor for proteins , 1991 .

[18]  F. Ergan,et al.  Reversible immobilization of an antibody with a thiol-substituted sorbent : Application to enzyme immunoassays , 1987 .

[19]  G. Frens Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions , 1973 .