Optimized 12-Pulse Rectifier With Generalized Delta Connection Autotransformer and Isolated SEPIC Converters for Sinusoidal Input Line Current Imposition

This paper discusses an alternative to reduce harmonic current distortion in a 12-pulse rectifier. The circuit is based on a generalized autotransformer connection with low power-to-core that feeds two isolated SEPIC converters. Compared to other passive devices operating as conventional 12-pulse rectifiers, besides a tight dc bus, the use of static converters can, by means of an active current imposition, provide very low harmonic distortion of current. This paper presents a theoretical analysis which is corroborated by computational and experimental results. The results show that the performance of the proposed converter is similar to the performance provided by three-phase unity power factor PWM rectifiers, however, only two active switches are deployed.

[1]  Jie Chen,et al.  Investigation on the selection of a more suitable power system architecture for future more electric aircraft from the prospective of system stability , 2017, 2017 IEEE 26th International Symposium on Industrial Electronics (ISIE).

[2]  F. D. de Seixas,et al.  AC-DC three-phase multipulse converter with boost DC-DC stage and constant hysteresis control , 2011, XI Brazilian Power Electronics Conference.

[3]  P. S. Oliveira,et al.  A new design methodology for multipulse rectifiers with Delta auto-connected transformers and a retrofit application in Adjustable Speed Drives (ASDs) , 2012, 2012 10th IEEE/IAS International Conference on Industry Applications.

[4]  F.J.M. de Seixas,et al.  A new three-phase low THD power supply with high-frequency isolation and 60V/200A regulated DC output , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[5]  Angelo C. Lourenco,et al.  18-pulse autotransformer rectifier unit using SEPIC converters for regulated DC-bus and high frequency isolation , 2015, 2015 IEEE 13th Brazilian Power Electronics Conference and 1st Southern Power Electronics Conference (COBEP/SPEC).

[6]  Sewan Choi,et al.  A new unity power factor telecom rectifier system by an active waveshaping technique , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[7]  Sewan Choi A three-phase unity-power-factor diode rectifier with active input current shaping , 2005, IEEE Trans. Ind. Electron..

[8]  I. Barbi,et al.  A 12 kW three-phase low THD rectifier with high-frequency isolation and regulated DC output , 2004, IEEE Transactions on Power Electronics.

[9]  Xiaona Xu,et al.  A Simple Harmonic Reduction Method in Multipulse Rectifier Using Passive Devices , 2017, IEEE Transactions on Industrial Informatics.

[10]  U. Drofenik,et al.  Comparative evaluation of three-phase high power factor AC-DC converter concepts for application in future more electric aircrafts , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[11]  Sewan Choi,et al.  A new active interphase reactor for 12-pulse rectifiers provides clean power utility interface , 1995 .

[12]  J. Kolar,et al.  Novel hybrid 12-pulse boost-type rectifier with controlled output voltage , 2005, IEEE Transactions on Aerospace and Electronic Systems.

[13]  Fanghua Zhang,et al.  12-pulse auto-transformer rectifier with harmonic current injection for non-grid-connected wind power applications , 2009, 2009 World Non-Grid-Connected Wind Power and Energy Conference.

[14]  Vinod Patel,et al.  An active interphase transformer for 12-pulse rectifier system to get the performance like 24-pulse rectifier system , 2014, 2014 Eighteenth National Power Systems Conference (NPSC).

[15]  Mahesh M. Swamy An electronically isolated 12 pulse autotransformer rectification scheme to improve input power factor and lower harmonic distortion in variable frequency drives , 2014 .

[16]  Fangang Meng,et al.  Effect of Single-Phasing on Multipulse Rectifier With Active Interphase Reactor , 2015, IEEE Transactions on Power Electronics.

[17]  Bhim Singh,et al.  Improvement in harmonic reduction of zigzag autoconnected transformer based 12-pulse diode bridge rectifier by current injection at DC side , 2016, 2016 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).

[18]  I. Barbi,et al.  A new 12 kW three-phase impulse high power factor AC-DC converter with regulated output voltage for rectifier units , 1999, 21st International Telecommunications Energy Conference. INTELEC '99 (Cat. No.99CH37007).

[19]  F. J. M. de Seixas,et al.  A Family of Autoconnected Transformers for 12- and 18-Pulse Converters—Generalization for Delta and Wye Topologies , 2011, IEEE Transactions on Power Electronics.