Compensation of voltage unbalance of a standalone CDFIG using repetitive rotor current control

This paper analyzes the unbalance problem of a standalone cascaded doubly-fed induction generator feeding unbalanced three-phase load. Under this working condition, the output voltages become un-balanced and give rise to a negative sequence component. The classic vector control strategy does not provide the desired performance. A compensation method is proposed to balance the stator voltages. The approach is developed based on a repetitive rotor current control implemented in a single positive reference frame. Simulations attest of the ability of the controller to reject the unbalanced load impact on the generated voltages.

[1]  Rita Mbayed,et al.  Repetitive control of an unbalanced standalone Doubly-Fed Induction Generator , 2012, 2012 International Conference on Renewable Energies for Developing Countries (REDEC).

[2]  Nicolas Patin,et al.  Modeling and Control of a Cascaded Doubly Fed Induction Generator Dedicated to Isolated Grids , 2009, IEEE Transactions on Industrial Electronics.

[3]  Thillainathan Logenthiran,et al.  Analysis and compensation of voltage unbalance of a DFIG using predictive rotor current control , 2016 .

[4]  Mi-Ching Tsai,et al.  Design of a plug-in type repetitive controller for periodic inputs , 2002, IEEE Trans. Control. Syst. Technol..

[5]  Dewei Xu,et al.  Modeling and Control of Brushless Doubly-Fed Induction Generators in Wind Energy Applications , 2008, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[6]  Nicolas Patin,et al.  Control of a cascaded doubly fed induction generator supplying an isolated DC grid , 2015, IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society.

[7]  Wei Zhang,et al.  Improved Vector Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Conditions for Offshore Wind Power Generation , 2016, IEEE Transactions on Energy Conversion.

[8]  S. Hara,et al.  Repetitive control system: a new type servo system for periodic exogenous signals , 1988 .

[9]  Ahmed M. Massoud,et al.  Ride-Through Capability of Grid-Connected Brushless Cascade DFIG Wind Turbines in Faulty Grid Conditions—A Comparative Study , 2013, IEEE Transactions on Sustainable Energy.

[10]  Paolo Mattavelli,et al.  Analog circuits to implement repetitive controllers for tracking and disturbance rejection of periodic signals , 2005, IEEE Transactions on Circuits and Systems II: Express Briefs.

[11]  W. Wonham,et al.  The internal model principle for linear multivariable regulators , 1975 .