Identification of the impedance model of an implanted cochlear prosthesis from intracochlear potential measurements

Those suffering from a severe to profound sensorineural hearing loss can obtain substantial benefit from a cochlear implant prosthesis. An electrode array implanted in the inner ear stimulates auditory nerve fibers by direct injection of electrical current. A major limitation of today's technology is the imprecise control of intracochlear current flow, particularly the relatively wide spread of neural excitation. A better understanding of the intracochlear electrical fields is, therefore, required. This paper analyzes the structure of intracochlear potential measurements in relation to both the subject's anatomy and to the properties of the electrode array. An electrically equivalent network is proposed, composed of small lumped circuits for the interface impedance and for the cochlear tissues. The numerical methods required to estimate the model parameters from high-quality electrical potential recordings are developed. Finally, some models are presented for subjects wearing a Clarion CII device with a HiFocus electrode and discussed in terms of model reliability.

[1]  Jeroen J Briaire,et al.  Field patterns in a 3D tapered spiral model of the electrically stimulated cochlea , 2000, Hearing Research.

[2]  R. Schoonhoven,et al.  Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea , 1995, Hearing Research.

[3]  B M Clopton,et al.  Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis. , 1982, The Annals of otology, rhinology & laryngology. Supplement.

[4]  J. D. Bourland,et al.  Faradic resistance of the electrode/electrolyte interface , 1992, Medical and Biological Engineering and Computing.

[5]  S Peeters,et al.  New developments in cochlear implants. , 1998, Acta oto-rhino-laryngologica Belgica.

[6]  J. Rauschecker,et al.  Sending Sound to the Brain , 2002, Science.

[7]  R. Shannon,et al.  Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. , 2001, The Journal of the Acoustical Society of America.

[8]  S. B. Brummer,et al.  Electrochemical Considerations for Safe Electrical Stimulation of the Nervous System with Platinum Electrodes , 1977, IEEE Transactions on Biomedical Engineering.

[9]  P. Stypulkowski,et al.  Single fiber mapping of spatial excitation patterns in the electrically stimulated auditory nerve , 1987, Hearing Research.

[10]  F. Spelman,et al.  Lumped-parameter model for in vivo cochlear stimulation , 1993, IEEE Transactions on Biomedical Engineering.

[11]  G. Girzon,et al.  Investigation of current flow in the inner ear during electrical stimulation of intracochlear electrodes , 1987 .

[12]  C. Jolly,et al.  Quadrupolar stimulation for cochlear prostheses: modeling and experimental data , 1996, IEEE Transactions on Biomedical Engineering.

[13]  T Hanekom,et al.  Three-Dimensional Spiraling Finite Element Model of the Electrically Stimulated Cochlea , 2001, Ear and hearing.

[14]  G M Clark,et al.  CURRENT DISTRIBUTIONS IN COCHLEAR STIMULATION a , 1983, Annals of the New York Academy of Sciences.

[15]  Robert de Levie The admittance of the interface between a metal electrode and an aqueous electrolyte solution: Some problems and pitfalls , 2006, Annals of Biomedical Engineering.

[16]  David Isaacson,et al.  Electrical Impedance Tomography , 2002, IEEE Trans. Medical Imaging.

[17]  D Strelioff A computer simulation of the generation and distribution of cochlear potentials. , 1973, The Journal of the Acoustical Society of America.

[18]  Philipos C. Loizou,et al.  Mimicking the human ear , 1998, IEEE Signal Process. Mag..

[19]  Charles C. Finley,et al.  Models of Neural Responsiveness to Electrical Stimulation , 1990 .

[20]  Norbert Dillier,et al.  Measurement of the Electrically Evoked Compound Action Potential via a Neural Response Telemetry System , 2002, The Annals of otology, rhinology, and laryngology.

[21]  L. Mens,et al.  The Clarion Electrode Positioner: Approximation to the Medial Wall and Current Focussing? , 2003, Audiology and Neurotology.

[22]  Jeroen J. Briaire,et al.  Initial Evaluation of the Clarion CII Cochlear Implant: Speech Perception and Neural Response Imaging , 2002, Ear and hearing.

[23]  Paul J. Abbas,et al.  A Longitudinal Study of Electrode Impedance, the Electrically Evoked Compound Action Potential, and Behavioral Measures in Nucleus 24 Cochlear Implant Users , 2001, Ear and hearing.

[24]  Johan Frijns,et al.  The Facial Nerve Canal: An Important Cochlear Conduction Path Revealed by Clarion Electrical Field Imaging , 2004, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[25]  Leon O. Chua,et al.  Linear and nonlinear circuits , 1987 .