Preprocedural CT evaluation of transcatheter aortic valve replacement: what the radiologist needs to know.

Aortic valve stenosis is the most common valvular heart disease in the Western world. When symptomatic, aortic valve stenosis is a debilitating disease with a dismal short-term prognosis, invariably leading to heart failure and death. Elective surgical valve replacement has traditionally been considered the standard of care for symptomatic aortic valve stenosis. However, several studies have identified various subgroups of patients with a significantly elevated risk for surgery-related complications and death. Thus, not every patient is a suitable candidate for surgery. Recent developments in transcatheter-based therapies have provided an alternative therapeutic strategy for the nonsurgical patient population known as transcatheter aortic valve replacement (TAVR) (also called transcatheter aortic valve implantation or percutaneous aortic valve replacement). In TAVR, the native aortic valve is replaced with a bioprosthetic valve via a nonsurgical endovascular, transaortic, or transapical pathway. Nevertheless, several anatomic and technical criteria must be met to safeguard patient eligibility and procedural success. Therefore, noninvasive imaging plays a crucial role in both patient selection and subsequent matching to a specific transcatheter valve size in an effort to ensure accurate prosthesis deployment and minimize peri- and postprocedural complications. The authors review the relevant anatomy of the aortic root, emphasizing the implications of anatomic pitfalls for correct reporting of imaging-derived measurements and important differences between findings obtained with different imaging modalities. They also discuss the evolving role of computed tomography and the role of the radiologist in patient triage in light of current viewpoints regarding patient selection, device size selection, and the preprocedural evaluation of possible access routes. Online supplemental material is available for this article.

[1]  Susheel Kodali,et al.  Two-Year Outcomes After Transcatheter or Surgical Aortic Valve Replacement , 2013 .

[2]  K. Furie,et al.  Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2007, Circulation.

[3]  M. Enriquez-Sarano,et al.  Measurement of aortic valve calcification using multislice computed tomography: correlation with haemodynamic severity of aortic stenosis and clinical implication for patients with low ejection fraction , 2010, Heart.

[4]  J. Webb,et al.  A new transcatheter aortic valve and percutaneous valve delivery system. , 2009, Journal of the American College of Cardiology.

[5]  S. Achenbach,et al.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). , 2012, Journal of cardiovascular computed tomography.

[6]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[7]  J. Leipsic,et al.  MDCT to guide transcatheter aortic valve replacement and mitral valve repair. , 2012, Cardiology clinics.

[8]  John W. Williams,et al.  Percutaneous Heart Valve Replacement for Aortic Stenosis: State of the Evidence , 2010, Annals of Internal Medicine.

[9]  D. Wood,et al.  Current balloon‐expandable transcatheter heart valve and delivery systems , 2010, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[10]  G. Feuchtner,et al.  Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation. , 2012, The Annals of thoracic surgery.

[11]  E. Schwammenthal,et al.  Transapical aortic valve implantation with a self-expanding anatomically oriented valve. , 2011, European heart journal.

[12]  S. Achenbach,et al.  CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: an analysis of 105 patients , 2013, The International Journal of Cardiovascular Imaging.

[13]  Michael Becker,et al.  Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation , 2011, Heart.

[14]  P. Serruys,et al.  Optimal projection estimation for transcatheter aortic valve implantation based on contrast‐aortography , 2010, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[15]  H. Niinuma,et al.  Diagnostic value of cardiac CT in the evaluation of bicuspid aortic stenosis: comparison with echocardiography and operative findings. , 2010, AJR. American journal of roentgenology.

[16]  G. Gerosa,et al.  Expanding the eligibility for transcatheter aortic valve implantation the trans-subclavian retrograde approach using: the III generation CoreValve revalving system. , 2009, JACC. Cardiovascular interventions.

[17]  Meyhöfer Juergen,et al.  Rotational angiography for preinterventional imaging in transcatheter aortic valve implantation , 2012 .

[18]  E. Tuzcu,et al.  Imaging for transcatheter valve procedures. , 2010, Current problems in cardiology.

[19]  M. Claeys,et al.  Alternative Access in Transcatheter Aortic Valve Implantation: Brachiocephalic Artery Access , 2012, Innovations.

[20]  M. Morice,et al.  Transfemoral aortic valve implantation new criteria to predict vascular complications. , 2011, JACC. Cardiovascular interventions.

[21]  D. Horstkotte,et al.  The natural history of aortic valve stenosis. , 1988, European heart journal.

[22]  Acute left main obstructions following TAVI. , 2010, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[23]  Lukas Altwegg,et al.  Prevention and management of transcatheter balloon‐expandable aortic valve malposition , 2008, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[24]  J. Dark,et al.  Aortic valve replacement in octogenarians , 2007, Journal of cardiothoracic surgery.

[25]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2009, Circulation.

[26]  Adriaan Moelker,et al.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? , 2010, European heart journal.

[27]  Thomas Walther,et al.  Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve , 2010, Circulation.

[28]  Susheel Kodali,et al.  ranscatheter Aortic Valve Implantation eview of the Nature , Management , and Avoidance of Procedural Complications , 2022 .

[29]  K. Kent,et al.  Utility of radiologic review for noncardiac findings on multislice computed tomography in patients with severe aortic stenosis evaluated for transcatheter aortic valve implantation. , 2010, The American journal of cardiology.

[30]  Hyuk-Jae Chang,et al.  Dual-Enhanced Cardiac CT for Detection of Left Atrial Appendage Thrombus in Patients With Stroke: A Prospective Comparison Study With Transesophageal Echocardiography , 2011, Stroke.

[31]  Mathias Prokop,et al.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. , 2006, Radiology.

[32]  J. Leipsic,et al.  Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. , 2012, Journal of the American College of Cardiology.

[33]  P. Serruys,et al.  Vascular complications with transcatheter aortic valve implantation using the 18 Fr Medtronic CoreValve System: the Rotterdam experience. , 2010, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[34]  S. Halliburton,et al.  Prevalence of significant peripheral artery disease in patients evaluated for percutaneous aortic valve insertion: Preprocedural assessment with multidetector computed tomography. , 2009, The Journal of thoracic and cardiovascular surgery.

[35]  L. Martinelli,et al.  Direct aortic access through right minithoracotomy for implantation of self-expanding aortic bioprosthetic valves. , 2010, The Journal of thoracic and cardiovascular surgery.

[36]  B. Carabello,et al.  Is an age of 80 years or greater an important predictor of short-term outcomes of isolated aortic valve replacement in veterans? , 2010, The Annals of thoracic surgery.

[37]  Francesco Maisano,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[38]  J. Gardin,et al.  Burden of valvular heart diseases: a population-based study , 2006, The Lancet.

[39]  R. Tölg,et al.  Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis. , 2010, Journal of the American College of Cardiology.

[40]  Fabien Hyafil,et al.  Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. , 2010, Journal of the American College of Cardiology.

[41]  J. Fajadet,et al.  Thirty-day outcome and vascular complications after transarterial aortic valve implantation using both Edwards Sapien and Medtronic CoreValve bioprostheses in a mixed population. , 2010, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[42]  Ricardo P. J. Budde,et al.  Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography , 2011, The International Journal of Cardiovascular Imaging.

[43]  P. Wenaweser,et al.  Transcatheter aortic valve implantation: the procedure , 2012, Heart.

[44]  Michael J. Mack,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[45]  Susheel Kodali,et al.  Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. , 2012, The New England journal of medicine.

[46]  Robert H. Anderson,et al.  Anatomy of the Aortic Valvar Complex and Its Implications for Transcatheter Implantation of the Aortic Valve , 2008, Circulation. Cardiovascular interventions.

[47]  O. Alfieri,et al.  VALVULAR AND STRUCTURAL HEART DISEASES Original Studies Predictors of Moderate-to-Severe Paravalvular Aortic Regurgitation Immediately After CoreValve Implantation and the Impact of Postdilatation , 2011 .

[48]  Rosario V. Freeman,et al.  Spectrum of Calcific Aortic Valve Disease: Pathogenesis, Disease Progression, and Treatment Strategies , 2005, Circulation.

[49]  S. Achenbach,et al.  3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. , 2012, Journal of the American College of Cardiology.

[50]  Philippe Ravaud,et al.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. , 2003, European heart journal.

[51]  Robert H. Anderson Demystifying the anatomic arrangement of the aortic valve. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[52]  P. Parizel,et al.  Comparison of magnetic resonance imaging of aortic valve stenosis and aortic root to multimodality imaging for selection of transcatheter aortic valve implantation candidates. , 2011, The American journal of cardiology.

[53]  R. Lange,et al.  Transcatheter aortic valve implantation through the ascending aorta: an alternative option for no-access patients. , 2009, The heart surgery forum.

[54]  A. Vahanian,et al.  Transcatheter valve implantation for patients with aortic stenosis , 2010, Heart.

[55]  S. Doshi,et al.  Delayed left main stem obstruction following successful TAVI with an Edwards SAPIEN XT valve: successful resuscitation and percutaneous coronary intervention using a non-invasive automated chest compression device (AutoPulse). , 2012, The Journal of invasive cardiology.

[56]  J. Leipsic,et al.  Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. , 2012, Journal of cardiovascular computed tomography.

[57]  J. Chambers,et al.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[58]  Pascal Vranckx,et al.  Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. , 2011, Journal of the American College of Cardiology.

[59]  B. De Bruyne,et al.  Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: results of the Belgian national registry. , 2011, Interactive cardiovascular and thoracic surgery.

[60]  W G Henderson,et al.  A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis. Veterans Affairs Cooperative Study on Valvular Heart Disease. , 1993, The New England journal of medicine.

[61]  A. Cheung,et al.  Transapical aortic valve implantation in humans. , 2006, The Journal of thoracic and cardiovascular surgery.

[62]  G. Latsios,et al.  Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. , 2010, JACC. Cardiovascular interventions.

[63]  Ghassan Sleilaty,et al.  Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. , 2008, Journal of the American College of Cardiology.

[64]  E. Tay,et al.  Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis. , 2010, JACC. Cardiovascular interventions.

[65]  Scott Lim,et al.  Two-year outcomes after transcatheter or surgical aortic-valve replacement. , 2012, The New England journal of medicine.

[66]  T. Hájek,et al.  Aortic annulus and ascending aorta: comparison of preoperative and periooperative measurement in patients with aortic stenosis. , 2010, European journal of radiology.

[67]  Jeroen J. Bax,et al.  Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. , 2008, JACC. Cardiovascular imaging.

[68]  R. Anderson Clinical anatomy of the aortic root , 2000, Heart.

[69]  Friedhelm Beyersdorf,et al.  Preoperative assessment of aortic annulus dimensions: comparison of noninvasive and intraoperative measurement. , 2011, The Annals of thoracic surgery.

[70]  A. Colombo,et al.  Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. , 2012, European heart journal.

[71]  D. Capodanno,et al.  Cardiovascular magnetic resonance for the assessment of patients undergoing transcatheter aortic valve implantation: a pilot study , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[72]  J. Leipsic,et al.  Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation. , 2010, JACC. Cardiovascular interventions.

[73]  Jeroen J. Bax,et al.  Transcatheter Aortic Valve Implantation: Role of Multi-slice Computed Tomography to Evaluate Prosthesis Positioning and Deployment in Relation to Valve Function , 2009 .

[74]  K. Furie,et al.  Heart disease and stroke statistics--2007 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2008, Circulation.

[75]  M. Cheitlin Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery , 2007 .

[76]  A. Shiran,et al.  Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[77]  P. Serruys,et al.  Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans‐thoracic echocardiography in patients referred for transcatheter aortic valve implantation , 2011, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[78]  M. Langer,et al.  Combined assessment of aortic root anatomy and aortoiliac vasculature with dual-source CT as a screening tool in patients evaluated for transcatheter aortic valve implantation. , 2010, AJR. American journal of roentgenology.

[79]  S. Halliburton,et al.  Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. , 2010, JACC. Cardiovascular interventions.

[80]  Jennifer Keegan,et al.  Aortic Root Measurement by Cardiovascular Magnetic Resonance: Specification of Planes and Lines of Measurement and Corresponding Normal Values , 2008, Circulation. Cardiovascular imaging.

[81]  S. Achenbach,et al.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode , 2011, European Radiology.

[82]  Nico Mollet,et al.  Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis. , 2009, Journal of the American College of Cardiology.

[83]  Matthias Gutberlet,et al.  Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation. , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[84]  Thomas Felderhoff,et al.  Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study , 2006 .

[85]  Jeroen J. Bax,et al.  Multimodality imaging in transcatheter aortic valve implantation: key steps to assess procedural feasibility. , 2010, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[86]  Nikolaus Marx,et al.  Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. , 2011, International journal of cardiology.

[87]  Ashraf Hamdan,et al.  Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. , 2012, Journal of the American College of Cardiology.

[88]  M. Worthley,et al.  Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole , 2012, The International Journal of Cardiovascular Imaging.

[89]  Alec Vahanian,et al.  Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. , 2009, JACC. Cardiovascular interventions.

[90]  F. Maisano,et al.  Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis , 2011, Circulation.

[91]  Ronen Gurvitch,et al.  Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. , 2011, JACC. Cardiovascular interventions.

[92]  J. Ennker,et al.  Aortic valve replacement in octogenarians: identification of high-risk patients. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.