Study on control method for the grid-connected inverter with LCL filter

LCL filer has been widely applied in modern grid-connected inverter systems. In this paper, the impacts of LCL filter parameters on the filtering effects of harmonics and the current tracking accuracy of grid-connected inverter are analyzed, and the relationships between the inverter-side and network-side currents of the grid-connected inverter under active and reactive current output situations are derived. In addition, in the LCL-filter-based grid-connected inverter system, the current tracking ability is affected by the filter capacitor current when using the traditional control method by inverter-side current feedback. To solve this problem, a method to calculate the network-side current using the inverter-side current is proposed, and the calculated network-side current is compared with the command current in the control system. With the proposed control method, the current tracking ability of the grid-connected inverter system is improved. Simulation results show the improved control method is correct and superior.

[1]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[2]  Wang Shouxiang,et al.  Study on Some Key Problems Related to Distributed Generation Systems , 2008 .

[3]  Friedrich Wilhelm Fuchs,et al.  PI state space current control of grid- connected PWM converters with LCL filters , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[4]  Xu Jia-zhu,et al.  LCL output filter design and the influence to the D-STATCOM compensation characteristic , 2011, 2011 International Conference on Electronics, Communications and Control (ICECC).

[5]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2003 .

[6]  Jian Liu,et al.  Structure and parameters design of output LC filter in D-STATCOM , 2010, 2010 International Conference on Power System Technology.

[7]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[8]  Duan Jiandong Control Strategy for Grid-connected Inverter With an LCL Output Filter , 2011 .

[9]  Zhihong Ye,et al.  Output filter design for a grid-interconnected three-phase inverter , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[10]  Dehong Xu,et al.  A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter , 2010, IEEE Transactions on Industrial Electronics.

[11]  Dehong Xu,et al.  An Improved Control Strategy for Grid-Connected Voltage Source Inverters With an LCL Filter , 2006, IEEE Transactions on Power Electronics.

[12]  Cao Renxian Strategy Design of Multiple Feedback Loop Control for Grid-connected Voltage Source Inverter with LCL Filter , 2011 .