A new standard for electrocardiographic (ECG) medical equipment is currently in development by the ISO/IEC Joint Work Group 22 (JWG22) and is entitled "80601, part 2-86: Particular requirements for the basic safety and essential performance of electrocardiographs, including diagnostic equipment, monitoring equipment, ambulatory equipment, electrodes, cables, and leadwires". This new standard will replace the current set of IEC particular standards that pertain to ECG equipment, namely, 60601-2-25 (diagnostic electrocardiographs), 60601-2-27 (ECG patient monitors), and 60601-2-47 (Ambulatory ECG) and also incorporates AAMI standards EC12 (disposable electrodes), EC53 (ECG cables and leadwires), and EC57 (arrhythmia analysis performance reporting). This new ECG device standard will define basic safety and essential performance requirements and compliance testing methods for all types of ECG devices including both legacy types of ECG devices as well as new types of ECG devices. In addition to the general requirements, specific requirements and testing methods will apply exclusively to devices claiming to be used as a diagnostic electrocardiograph, an ECG patient monitor, and or an ambulatory ECG device. The primary goal of the work to develop this new ECG standard is to combine and harmonize the content of the existing set of 6 ECG standards. In addition, because many of these standards are quite mature, this work provides an opportunity to update the content to align requirements and testing methods with changes in ECG technology as well as changes in the clinical use of ECG and the emergence of new types of ECG devices. The changes under consideration and the progress of this work by ISO/IEC JWG22 is reviewed. Specific updates are highlighted, including requirements for defibrillation recovery, changes for ECG filtering technology, and changes to address advancement in implanted pacing technology.
[1]
P. Macfarlane,et al.
Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology,
,
1990,
Circulation.
[2]
Tahir Zaidi,et al.
An Intelligent Adaptive Filter for Elimination of Power Line Interference From High Resolution Electrocardiogram
,
2016,
IEEE Access.
[3]
S. Swiryn,et al.
High resolution electrocardiography optimised for recording pulses from electronic pacemakers: Evaluation of a new pacemaker sensing system
,
2007,
2007 Computers in Cardiology.
[4]
Alan V Sahakian,et al.
The relationship between programmed pacemaker pulse amplitude and the surface electrocardiogram recorded amplitude: application of a new high-bandwidth electrocardiogram system.
,
2008,
Journal of electrocardiology.
[5]
S. Swiryn,et al.
Improved pacemaker pulse detection: clinical evaluation of a new high-bandwidth electrocardiographic system.
,
2011,
Journal of electrocardiology.
[6]
E. W. Hancock,et al.
AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American
,
2009,
Journal of the American College of Cardiology.