A new implementation of a multiport automatic network analyzer

A generalized multiport network analyzer implemented using commercially available hardware is presented. Measurement calibration is accomplished through a novel calibration procedure which requires only conventional standards used for two-port calibrations. The calibration theory accounts for the errors due to the signal switching network but does not systematically remove errors due to signal switching leakage between port pairs. The approach is verified on a three-port test set implementation, and the measuring system can be expanded to n ports with additional hardware in a straightforward manner. Experimental verification was carried out through measurement of one-, two-, and three-port devices connected to the test set ports in several different ways. Excellent agreement of the same corrected S-parameters measured at different test set ports was observed, and confidence in system accuracy is established through measurement of two-port verification standards. >

[1]  S. Rehnmark,et al.  On the Calibration Process of Automatic Network Analyzer Systems (Short Papers) , 1974 .

[2]  R. Speciale,et al.  A Rigorous Technique for Measuring the Scattering Matrix of a Multiport Device with a 2-Port Network Analyzer , 1982 .

[3]  G. F. Engen,et al.  Thru-Reflect-Line: An Improved Technique for Calibrating the Dual Six-Port Automatic Network Analyzer , 1979 .

[4]  R. A. Speciale A Generalization of the TSD Network-Analyzer Calibration Procedure, Covering n-Port Scattering-Parameter Measurements, Affected by Leakage Errors , 1977 .

[5]  B. Schiek,et al.  A generalized theory and new calibration procedures for network analyzer self-calibration , 1991 .

[6]  R. D. Pollard,et al.  16-term error model and calibration procedure for on wafer network analysis measurements (MMICs) , 1991 .

[7]  K. F. Sodomsky,et al.  An Explicit Solution for the Scattering Parameters of a Linear Two-Port Measured with an Imperfect Test Set (Correspondence) , 1971 .

[8]  R.A. Speciale,et al.  Super - TSD, A Generalization of the TSD Network Analyzer Calibration Procedure, Covering n - Port Measurements with Leakage , 1977, 1977 IEEE MTT-S International Microwave Symposium Digest.

[9]  Andrea Ferrero,et al.  QSOLT: A New Fast Calibration Algorithm for Two Port S Parameter Measurements , 1991, 38th ARFTG Conference Digest.

[10]  V. G. Gelnovatch A Computer Program for the Direct Calibration of Two- Port Reflectometers for Automated Microwave Measurements (Short Papers) , 1976 .

[11]  Hermann Eul,et al.  Reducing the number of calibration standards for network analyzer calibration , 1991 .

[12]  G. F. Engen,et al.  Calibration Technique for Automated Network Analyzers with Application to Adapter Evaluation , 1974 .

[13]  R. Soares,et al.  A unified mathematical approach to two-port calibration techniques and some applications , 1989 .