Comparison of a single‐channel EEG sleep study to polysomnography

An accurate home sleep study to assess electroencephalography (EEG)‐based sleep stages and EEG power would be advantageous for both clinical and research purposes, such as for longitudinal studies measuring changes in sleep stages over time. The purpose of this study was to compare sleep scoring of a single‐channel EEG recorded simultaneously on the forehead against attended polysomnography. Participants were recruited from both a clinical sleep centre and a longitudinal research study investigating cognitively normal ageing and Alzheimer's disease. Analysis for overall epoch‐by‐epoch agreement found strong and substantial agreement between the single‐channel EEG compared to polysomnography (κ = 0.67). Slow wave activity in the frontal regions was also similar when comparing the single‐channel EEG device to polysomnography. As expected, Stage N1 showed poor agreement (sensitivity 0.2) due to lack of occipital electrodes. Other sleep parameters, such as sleep latency and rapid eye movement (REM) onset latency, had decreased agreement. Participants with disrupted sleep consolidation, such as from obstructive sleep apnea, also had poor agreement. We suspect that disagreement in sleep parameters between the single‐channel EEG and polysomnography is due partially to altered waveform morphology and/or poorer signal quality in the single‐channel derivation. Our results show that single‐channel EEG provides comparable results to polysomnography in assessing REM, combined Stages N2 and N3 sleep and several other parameters, including frontal slow wave activity. The data establish that single‐channel EEG can be a useful research tool.

[1]  W. B. Webb,et al.  The first night effect: an EEG study of sleep. , 1966, Psychophysiology.

[2]  Maya Ringli,et al.  Mapping of Cortical Activity in the First Two Decades of Life: A High-Density Sleep Electroencephalogram Study , 2010, The Journal of Neuroscience.

[3]  Gerhard Klösch,et al.  Scalp Topography of the Spontaneous K-Complex and of Delta-Waves in Human Sleep , 2004, Brain Topography.

[4]  R. Rosenberg,et al.  The American Academy of Sleep Medicine inter-scorer reliability program: sleep stage scoring. , 2013, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[5]  A A Borbély,et al.  Recording the sleep EEG with periorbital skin electrodes. , 1995, Electroencephalography and clinical neurophysiology.

[6]  John R. Shambroom,et al.  Validation of an automated wireless system to monitor sleep in healthy adults , 2012, Journal of sleep research.

[7]  Gérard Waeber,et al.  Age and gender variations of sleep in subjects without sleep disorders , 2015, Annals of medicine.

[8]  A. Chesson,et al.  The American Academy of Sleep Medicine (AASM) Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications , 2007 .

[9]  P. Achermann,et al.  Spindle frequency activity in the sleep EEG: individual differences and topographic distribution. , 1997, Electroencephalography and clinical neurophysiology.

[10]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[11]  Julie Carrier,et al.  Topography of age-related changes in sleep spindles , 2013, Neurobiology of Aging.

[12]  C. Doré,et al.  EEG electrode positions outside the hairline to monitor sleep in man. , 1984, Sleep.

[13]  D. Altman,et al.  Statistics Notes: Diagnostic tests 1: sensitivity and specificity , 1994, BMJ.

[14]  Peter Achermann,et al.  Individual ‘Fingerprints’ in Human Sleep EEG Topography , 2001, Neuropsychopharmacology.

[15]  A A Borbély,et al.  Brain topography of the human sleep EEG: antero‐posterior shifts of spectral power , 1996, Neuroreport.

[16]  Giulio Tononi,et al.  Antidepressant effects of selective slow wave sleep deprivation in major depression: a high-density EEG investigation. , 2011, Journal of psychiatric research.

[17]  C. Guilleminault,et al.  Comparison of actigraphic, polysomnographic, and subjective assessment of sleep parameters in sleep-disordered patients. , 2001, Sleep medicine.

[18]  Djordje Popovic,et al.  Scoring accuracy of automated sleep staging from a bipolar electroocular recording compared to manual scoring by multiple raters. , 2013, Sleep medicine.

[19]  Djordje Popovic,et al.  Automatic scoring of sleep stages and cortical arousals using two electrodes on the forehead: validation in healthy adults , 2014, Journal of sleep research.

[20]  M. Kendall Statistical Methods for Research Workers , 1937, Nature.

[21]  G. Tononi,et al.  Sleep-dependent improvement in visuomotor learning: a causal role for slow waves. , 2009, Sleep.

[22]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.