Shock Occurrence and Survival in 241 Patients With Implantable Cardioverter‐ Defibrillator Therapy

BackgroundThe purpose of this study was to determine the influence of clinical characteristics on shock occurrence and survival in 241 patients with implantable cardioverter-defibrillator (ICD) therapy Methods and ResultsTwo hundred forty-one consecutive patients underwent ICD implantation between November 1982 and November 1991 and were subsequently followed for 26±22 months (intention-to-treat analysis). Actuarial incidence of “appropriate” shocks was 13%, 42%, and 63%, and the incidence of any spontaneous shocks was 15%, 51%, and 76% at 1, 3, and 5 years of follow-up, respectively. Poor left ventricular function (ejection fraction $30%) was associated with an earlier occurrence of both appropriate and any spontaneous ICD shocks (p=0.001). Appropriate and any spontaneous shocks occurred significantly later in patients who presented with cardiac arrest and in patients in whom only ventricular fibrillation but no uniform ventricular tachycardia was induced during preoperative programmed stimulation. In addition, amiodarone treatment at implant was associated with later occurrence of any spontaneous shocks. Cumulative survival from all-cause mortality including perioperative mortality was 84%, 62%, and 57%, and survival from arrhythmic death was 97%, 89%o, and 83% at 1, 3, and 5 years, respectively. Ejection fraction $30% was the best predictor of both total arrhythmic death (p=0.019) and total mortality (p=0.003). Antiarrhythmic therapy with class 1 agents at implant was also associated with a higher total mortality during follow-up (p=0.023) but not with total arrhythmic death. Age, sex, underlying heart disease, clinical presentation, and preoperative response to programmed stimulation did not predict long-term survival. In addition, survival curves were similar for patients with and without spontaneous shocks. ConclusionThe majority of patients receive shocks during long-term follow-up. The occurrence of appropriate or any spontaneous shocks during follow-up is not associated with increased arrhythmic or total mortality consistent with effective prevention of sudden cardiac death with ICD therapy in this high-risk patient population. Although low ejection fraction is the strongest predictor of both shock occurrence and mortality during follow-up, no easy algorithm can be derived from the analyzed clinical characteristics to predict which patients will benefit most from ICD implantation.

[1]  R. Fogoros,et al.  Actuarial Incidence and Pattern of Occurrence of Shocks Following Implantation of the Automatic Implantable Cardioverter Defibrillator , 1989, Pacing and clinical electrophysiology : PACE.

[2]  V L Gott,et al.  Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. , 1980, The New England journal of medicine.

[3]  Elisa T. Lee,et al.  Statistical Methods for Survival Data Analysis , 1994, IEEE Transactions on Reliability.

[4]  J. Fisher,et al.  Sudden Death Mortality in Implantable Cardioverter Defibrillator Patients , 1991, Pacing and clinical electrophysiology : PACE.

[5]  A. Castellanos,et al.  Time to first shock and clinical outcome in patients receiving an automatic implantable cardioverter-defibrillator. , 1989, Journal of the American College of Cardiology.

[6]  T. Guarnieri,et al.  Follow-up of patients with ventricular tachyarrhythmia treated with the automatic implantable cardioverter defibrillator: Programmed electrical stimulation results do not predict clinical outcome , 1989 .

[7]  J. Elson,et al.  Survival of Patients Who Have Received Appropriate Shocks from Their Implantahle Defibrillators , 1991, Pacing and clinical electrophysiology : PACE.

[8]  M. Lehmann,et al.  Operative mortality with implantation of the automatic cardioverter-defibrillator. , 1991, The American journal of cardiology.

[9]  B. Wilkoff,et al.  Six‐Year Clinical Experience with the Automatic Implantable Cardioverter Defibrillator , 1991, Pacing and clinical electrophysiology : PACE.

[10]  R. Fogoros,et al.  Efficacy of the automatic implantable cardioverter-defibrillator in prolonging survival in patients with severe underlying cardiac disease. , 1990, Journal of the American College of Cardiology.

[11]  P. Tchou,et al.  Does Reception of Appropriate Shocks from the Implantable Cardioverter Defibrillator Affect Survival? , 1991, Pacing and clinical electrophysiology : PACE.

[12]  P E Oyer,et al.  Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. , 1985, Circulation.

[13]  J. Ruskin,et al.  The automatic implantable cardioverter-defibrillator: efficacy, complications and survival in patients with malignant ventricular arrhythmias. , 1988, Journal of the American College of Cardiology.

[14]  H. Trappe,et al.  Implantable Cardioverter Defibrillator Therapy: Indications and Decision Making in Patients with Coronary Artery Disease , 1992, Pacing and clinical electrophysiology : PACE.

[15]  T. Guarnieri,et al.  Predictors of First Discharge and Subsequent Survival in Patients With Automatic Implantable Cardioverter‐Defibrillators , 1991, Circulation.

[16]  J. Fisher,et al.  Influence of Left Ventricular Function on Outcome of Patients Treated With Implantable Defibrillators , 1992, Circulation.

[17]  R. Winkle,et al.  Long-term outcome with the automatic implantable cardioverter-defibrillator. , 1989, Journal of the American College of Cardiology.

[18]  S. Furman,et al.  Influence of Clinical Characteristics and Shock Occurrence on ICD Patient Outcome: A Multicenter Report , 1991, Pacing and clinical electrophysiology : PACE.

[19]  J. Langberg,et al.  Survival after implantation of the cardioverter defibrillator. , 1992, The American journal of cardiology.

[20]  F. Marchlinski,et al.  Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapy. , 1991, Journal of the American College of Cardiology.

[21]  P. Tchou,et al.  Survival in Patients with Depressed Left Ventricular Function Treated by Implantable Cardioverter Defibrillator , 1991, Pacing and clinical electrophysiology : PACE.

[22]  J. Fisher,et al.  Occurrence of ICD Shocks and Patient Survival , 1991, Pacing and clinical electrophysiology : PACE.

[23]  A C Thomas,et al.  Implantable Defibrillation: Eight Years Clinical Experience , 1988, Pacing and clinical electrophysiology : PACE.

[24]  P. Tchou,et al.  When Is it Safe not to Replace an Implantable Cardioverter Defibrillator Generator? , 1991, Pacing and clinical electrophysiology : PACE.