Zero energy buildings and sustainable development implications – A review

Buildings account for a significant proportion of the total energy and carbon emissions worldwide, and play an important role in formulating sustainable development strategies. There is a growing interest in ZEBs (zero energy buildings) in recent years. Several countries have adopted or considering establishing ZEBs as their future building energy targets to help alleviate the problems concerning the depletion of energy resources and the deterioration of the environment. Broadly speaking, ZEBs involve two design strategies – minimizing the need for energy use in buildings (especially for heating and cooling) through EEMs (energy-efficient measures) and adopting RETs (renewable energy and other technologies) to meet the remaining energy needs. This paper reviews the works related to these two strategies. EEMs include building envelopes, internal conditions, and building services systems; RETs cover photovoltaic/building-integrated photovoltaic, wind turbines, solar thermal (solar water heaters), heat pumps, and district heating and cooling. Issues pertaining to sustainable development implications and further research work required are also highlighted. These include life-cycle cost and environmental impacts, climate change and social policy issues.

[1]  Hongguang Jin,et al.  The energy situation and its sustainable development strategy in China , 2011 .

[2]  Martin K T Wu BSc MSc CEng Mhkie Miee Mcibse,et al.  Office Lighting Retrofit Using Dimmable Electronic Ballasts and Occupancy Controls , 2001 .

[3]  S. N. Garg,et al.  Energy rating of different glazings for Indian climates , 2009 .

[4]  Ismat Nawaz,et al.  Embodied energy analysis of photovoltaic (PV) system based on macro- and micro- level , 2006 .

[5]  Jian Zuo,et al.  Green building research–current status and future agenda: A review , 2014 .

[6]  Jiaping Liu,et al.  Development of passive design zones in China using bioclimatic approach , 2006 .

[7]  Ali Naci Celik,et al.  Optimisation and techno-economic analysis of autonomous photovoltaic–wind hybrid energy systems in comparison to single photovoltaic and wind systems , 2002 .

[8]  Wen Liu,et al.  The Potential of Renewable Energy Systems in China , 2009 .

[9]  Tianzhen Hong,et al.  An insight into actual energy use and its drivers in high-performance buildings , 2014 .

[10]  Riccardo Maria Pulselli,et al.  Energy and emergy based cost–benefit evaluation of building envelopes relative to geographical location and climate , 2009 .

[11]  Hassan Radhi,et al.  Evaluating the potential impact of global warming on the UAE residential buildings – A contribution to reduce the CO2 emissions , 2009 .

[12]  Scott Drake,et al.  Occupant comfort in naturally ventilated and mixed-mode spaces within air-conditioned offices , 2010 .

[13]  Gregory M. Maxwell,et al.  An empirical validation of the daylighting algorithms and associated interactions in building energy simulation programs using various shading devices and windows , 2007 .

[14]  Bin-Juine Huang,et al.  Study of system dynamics model and control of a high-power LED lighting luminaire , 2007 .

[15]  Saeed Zeinali Heris,et al.  Experimental investigation of the effects of silica/water nanofluid on PV/T (photovoltaic thermal units) , 2014 .

[16]  Mariesa L. Crow,et al.  Performance evaluation of energy efficient lighting associated with renewable energy applications , 2012 .

[17]  Danny H.W. Li,et al.  Energy and cost analysis of semi-transparent photovoltaic in office buildings , 2009 .

[18]  Wenming Yang,et al.  Advances in heat pump systems: A review , 2010 .

[19]  Zheng Li,et al.  The use of energy in China: Tracing the flow of energy from primary source to demand drivers , 2012 .

[20]  Onder Ozgener,et al.  Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings , 2010 .

[21]  T. Muneer,et al.  Solar Radiation and Daylight Models: For the Energy Efficient Design of Buildings , 1997 .

[22]  Danny H.W. Li,et al.  Daylighting and energy analysis for air-conditioned office buildings , 1998 .

[23]  Weifeng Zhu,et al.  Energy Conservation Using Variable-speed Chilled Water Pumps for Single-loop Chilled Water Systems with Fan-coil Units , 2003 .

[24]  Shang-Liang Chen,et al.  Theoretical and experimental investigations of a two-phase thermosyphon solar water heater , 2011 .

[25]  Gail Brager,et al.  Developing an adaptive model of thermal comfort and preference , 1998 .

[26]  Tariq Muneer,et al.  Windows in buildings : thermal, acoustic, visual and solar performance , 2000 .

[27]  Joshua D. Kneifel,et al.  Beyond the code: Energy, carbon, and cost savings using conventional technologies , 2011 .

[28]  Danny H.W. Li,et al.  Electricity use characteristics of purpose-built office buildings in subtropical climates , 2004 .

[29]  Per Heiselberg,et al.  Zero energy buildings and mismatch compensation factors , 2011 .

[30]  E. Halawa,et al.  The adaptive approach to thermal comfort: A critical overview , 2012 .

[31]  Francis A Kulacki,et al.  Utility scale hybrid wind–solar thermal electrical generation: A case study for Minnesota , 2008 .

[32]  Danny H.W. Li,et al.  Daylighting and its implications to overall thermal transfer value (OTTV) determinations , 2002 .

[33]  Danijela Nikolić,et al.  Toward a positive-net-energy residential building in Serbian conditions , 2011 .

[34]  Gregor P. Henze,et al.  Sensitivity analysis of optimal building thermal mass control , 2007 .

[35]  S. Boixo,et al.  Potential energy savings from cool roofs in Spain and Andalusia , 2012 .

[36]  Paul Kenny,et al.  From net energy to zero energy buildings: Defining life cycle zero energy buildings (LC-ZEB) , 2010 .

[37]  Giuliano Dall'O',et al.  Nearly Zero-Energy Buildings of the Lombardy Region (Italy), a Case Study of High-Energy Performance Buildings , 2013 .

[38]  Paris A. Fokaides,et al.  Legislation driven scenarios based on recent construction advancements towards the achievement of nearly zero energy dwellings in the southern European country of Cyprus , 2014 .

[39]  K. Chong,et al.  Study of a solar water heater using stationary V-trough collector , 2012 .

[40]  L. J. Grobler,et al.  A new and innovative look at anti-insulation behaviour in building energy consumption , 2008 .

[41]  Danny H.W. Li,et al.  A study of grid-connected photovoltaic (PV) system in Hong Kong , 2012 .

[42]  Geetanjali Tiwari,et al.  Technical performance evaluation of stand-alone photovoltaic array for outdoor field conditions of New Delhi , 2012 .

[43]  J. C. Lam,et al.  An analysis of daylighting and solar heat for cooling-dominated office buildings , 1999 .

[44]  Richard de Dear,et al.  Green occupants for green buildings: The missing link? , 2012 .

[45]  K. F. Fong,et al.  Towards net zero energy design for low-rise residential buildings in subtropical Hong Kong , 2012 .

[46]  Yang Wang,et al.  Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit , 2014 .

[47]  Raffaele Bornatico,et al.  Optimal sizing of a solar thermal building installation using particle swarm optimization , 2012 .

[48]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .

[49]  J. C. Lam,et al.  Energy performance of building envelopes in different climate zones in China , 2008 .

[50]  Ying Li,et al.  Thermal performance analysis of a direct-expansion solar-assisted heat pump water heater , 2011 .

[51]  Baruch Givoni,et al.  Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periods , 1998 .

[52]  Yusuf Yildiz,et al.  Identification of the building parameters that influence heating and cooling energy loads for apartm , 2011 .

[53]  J. C. Lam,et al.  Impact of climate change on building energy use in different climate zones and mitigation and adaptation implications , 2012 .

[54]  M. Barak,et al.  Effect on energy use and greenhouse microclimate through fan motor control by variable frequency drives , 2004 .

[55]  C.Y. Jim,et al.  Theoretical evaluation of thermal and energy performance of tropical green roofs , 2011 .

[56]  Jinggang Wang,et al.  Study on hybrid ground-coupled heat pump system for air-conditioning in hot-weather areas like Hong Kong , 2010 .

[57]  S. C. Solanki,et al.  Photovoltaic modules and their applications: A review on thermal modelling , 2011 .

[58]  Chin-Hsiang Cheng,et al.  Development of an energy-saving module via combination of solar cells and thermoelectric coolers for green building applications , 2011 .

[59]  Ying Fan,et al.  Exploring energy consumption and demand in China , 2012 .

[60]  Naouel Daouas,et al.  A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loads , 2011 .

[61]  S. Kalogirou Solar Energy Engineering: Processes and Systems , 2009 .

[62]  Wang Yi,et al.  PV (photovoltaics) performance evaluation and simulation-based energy yield prediction for tropical buildings , 2014 .

[63]  Siaw Kiang Chou,et al.  Energy performance of residential buildings in Singapore , 2010 .

[64]  Pei Liu,et al.  Integrated energy strategy for the sustainable development of China , 2011 .

[65]  Bernd Möller,et al.  Excess heat production of future net zero energy buildings within district heating areas in Denmark , 2012 .

[66]  Paul Gerard Tuohy,et al.  Twenty first century standards for thermal comfort: fostering low carbon building design and operation , 2010 .

[67]  Mary Ann Piette,et al.  Advanced energy-efficient lighting systems: Progress and potential , 1993 .

[68]  M. Noro,et al.  Solar cooling between thermal and photovoltaic: An energy and economic comparative study in the Mediterranean conditions , 2014 .

[69]  Nurettin Yamankaradeniz,et al.  Experimental study of horizontal ground source heat pump performance for mild climate in Turkey , 2009 .

[70]  Minoru Mizuno,et al.  Verification of energy efficiency of district heating and cooling system by simulation considering design and operation parameters , 2008 .

[71]  Yang Liu,et al.  A new method to develop typical weather years in different climates for building energy use studies , 2011 .

[72]  Wai Ming To,et al.  Association between energy use and poor visibility in Hong Kong SAR, China , 2014, Energy.

[73]  Philip C.H. Yu,et al.  A discussion on potentials of saving energy use for commercial buildings in Hong Kong , 2007 .

[74]  Liu Yang,et al.  Sensitivity analysis and energy conservation measures implications , 2008 .

[75]  John Burnett,et al.  Influence of envelope and partition characteristics on the space cooling of high-rise residential buildings in Hong Kong , 2002 .

[76]  Joel Ann Todd,et al.  Continuous Improvement of the U.S. Green Building Council's Leadership in Energy and Environmental Design (LEED®) Rating System™ , 2008 .

[77]  Himangshu Ranjan Ghosh,et al.  Prospect of wind–PV-battery hybrid power system as an alternative to grid extension in Bangladesh , 2010 .

[78]  S. Svendsen,et al.  Residential and commercial buildings , 2012 .

[79]  Zhengen Ren,et al.  Climate change adaptation pathways for Australian residential buildings , 2011 .

[80]  Volker Coors,et al.  Large scale integration of photovoltaics in cities , 2012 .

[81]  Ivan Vera,et al.  Energy indicators for sustainable development , 2007 .

[82]  Geoff Levermore,et al.  A review of the IPCC Assessment Report Four, Part 1: the IPCC process and greenhouse gas emission trends from buildings worldwide , 2008 .

[83]  Robert F. Boehm,et al.  Measurements and simulations for peak electrical load reduction in cooling dominated climate , 2012 .

[84]  Eike Musall,et al.  Zero Energy Building A review of definitions and calculation methodologies , 2011 .

[85]  Per Heiselberg,et al.  Life cycle cost analysis of a multi-storey residential Net Zero Energy Building in Denmark , 2011 .

[86]  Peter E.D. Love,et al.  Net energy analysis of solar and conventional domestic hot water systems in Melbourne, Australia , 2001 .

[87]  Meredydd Evans,et al.  Scenarios of building energy demand for China with a detailed regional representation , 2014 .

[88]  Carlos Ernesto Ochoa,et al.  Simulation-based method to determine climatic energy strategies of an adaptable building retrofit façade system , 2014 .

[89]  Liu Yang,et al.  Impacts of lighting density on heating and cooling loads in different climates in China , 2006 .

[90]  Andrew Cripps,et al.  The economic and environmental optimisation of integrating ground source energy systems into buildings , 2009 .

[91]  Patrick James,et al.  Climate change future proofing of buildings—Generation and assessment of building simulation weather files , 2008 .

[92]  T. Muneer,et al.  Life cycle assessment: A case study of a dwelling home in Scotland , 2007 .

[93]  Liwei Tian,et al.  Evaluation on energy and thermal performance for residential envelopes in hot summer and cold winter zone of China , 2009 .

[94]  Brian Vad Mathiesen,et al.  Large-scale integration of wind power into the existing Chinese energy system , 2011 .

[95]  Xiliang Zhang,et al.  Technologies and policies for the transition to a sustainable energy system in china , 2010 .

[96]  Marc A. Rosen,et al.  District heating and cooling: Review of technology and potential enhancements , 2012 .

[97]  Jordan Macknick,et al.  The power of efficiency: Optimizing environmental and social benefits through demand-side-management , 2014 .

[98]  Aoife Foley,et al.  Current methods and advances in forecasting of wind power generation , 2012 .

[99]  Sai On Cheung,et al.  Residential building envelope heat gain and cooling energy requirements , 2005 .

[100]  Soteris A. Kalogirou,et al.  Simulation and optimization of a LiBr solar absorption cooling system with evacuated tube collectors , 2005 .

[101]  Zoltán Nagy,et al.  Balancing envelope and heating system parameters for zero emissions retrofit using building sensor data , 2014 .

[102]  H. Manz,et al.  Climatic potential for passive cooling of buildings by night-time ventilation in Europe , 2007 .

[103]  Tariq Muneer,et al.  Energy and environmental impact analysis of double-glazed windows , 1998 .

[104]  Yan Su,et al.  Real-time prediction models for output power and efficiency of grid-connected solar photovoltaic systems , 2012 .

[105]  Teuku Meurah Indra Mahlia,et al.  Cost benefits analysis and emission reductions of optimum thickness and air gaps for selected insulation materials for building walls in Maldives , 2010 .

[106]  Theodore F. Smith,et al.  Evaluation of variable volume and temperature HVAC system for commercial and residential buildings , 1996 .

[107]  R. Dedear Developing an adaptive model of thermal comfort and preference , 1998 .

[108]  Danny H.W. Li,et al.  An analysis of energy-efficient light fittings and lighting controls , 2010 .

[109]  Joseph C. Lam,et al.  Sensitivity analysis of energy performance of office buildings , 1996 .

[110]  Liu Yang,et al.  Thermal comfort and building energy consumption implications - A review , 2014 .

[111]  Michael I. Gentry,et al.  Central heating thermostat settings and timing: building demographics , 2010 .

[112]  Matteo Bonifacio,et al.  Building a low carbon society , 2011 .

[113]  J. C. Lam,et al.  Future trends of building heating and cooling loads and energy consumption in different climates , 2011 .

[114]  Mark Luther,et al.  Energy efficient envelope design for high-rise apartments , 2005 .

[115]  Philip C. Eames,et al.  Interventions for large-scale carbon emission reductions in future UK offices , 2009 .

[116]  E. Caamaño-Martín,et al.  Energy saving potential of semi-transparent photovoltaic elements for building integration , 2014 .

[117]  Liwei Tian,et al.  A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China , 2009 .

[118]  Farouk Fardoun,et al.  Air source heat pump water heater: Dynamic modeling, optimal energy management and mini-tubes condensers , 2014 .

[119]  Lisa Guan Energy use, indoor temperature and possible adaptation strategies for air-conditioned office buildings in face of global warming , 2012 .

[120]  Soteris A. Kalogirou,et al.  Performance enhancement of an integrated collector storage hot water system , 1999 .

[121]  Mark Gaterell,et al.  The impact of climate change uncertainties on the performance of energy efficiency measures applied to dwellings , 2005 .

[122]  Roman Jaques,et al.  Impacts of climate change on building performance in New Zealand , 2001 .

[123]  G. Levermore,et al.  Future energy demand for public buildings in the context of climate change for Burkina Faso , 2012 .

[124]  Richard de Dear,et al.  A preliminary evaluation of two strategies for raising indoor air temperature setpoints in office buildings , 2011 .

[125]  Kuan Chen,et al.  New developments in illumination, heating and cooling technologies for energy-efficient buildings , 2010 .

[126]  Edward Morofsky,et al.  Effectiveness of single and multiple energy retrofit measures on the energy consumption of office bu , 2011 .

[127]  Danny H.W. Li,et al.  Impact of climate change on energy use in the built environment in different climate zones – A review , 2012 .

[128]  T. Frank,et al.  Climate change impacts on building heating and cooling energy demand in Switzerland , 2005 .

[129]  U. K. Rout,et al.  Energy and emissions forecast of China over a long-time horizon , 2011 .

[130]  Tony Pereira,et al.  The transition to a sustainable society: a new social contract , 2012, Environment, Development and Sustainability.

[131]  Milorad Bojić,et al.  Thermal insulation of cooled spaces in high rise residential buildings in Hong Kong , 2002 .

[132]  Adisa Azapagic,et al.  Domestic heat pumps: Life cycle environmental impacts and potential implications for the UK , 2012 .

[133]  Yoshiyuki Shimoda,et al.  City-level energy and CO 2 reduction effect by introducing new residential water heaters , 2010 .

[134]  V. Badescu,et al.  Warm season cooling requirements for passive buildings in Southeastern Europe (Romania) , 2010 .

[135]  Miroslav Premrov,et al.  Economical optimization of energy-efficient timber buildings: Case study for single family timber house in Slovenia , 2014 .

[136]  Alemayehu Gebremedhin,et al.  Introducing District Heating in a Norwegian town – Potential for reduced Local and Global Emissions , 2012 .

[137]  M. Jovanović,et al.  Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia , 2014 .

[138]  C. Karras,et al.  Electricity savings and CO2 emissions reduction in buildings sector: How important the network losses are in the calculation? , 2010 .

[139]  Liu Yang,et al.  Building energy efficiency in different climates , 2008 .

[140]  C. Cleveland Net energy from the extraction of oil and gas in the United States , 2005 .

[141]  Cheng Tian,et al.  A generalized window energy rating system for typical office buildings , 2010 .

[142]  Joseph C. Lam Building envelope loads and commercial sector electricity use in Hong Kong , 1995 .

[143]  M. Kummert,et al.  Designing net-zero energy buildings for the future climate, not for the past , 2012 .

[144]  Roland Clift,et al.  Climate change and energy policy: The importance of sustainability arguments , 2007 .

[145]  R. Schaeffer,et al.  Energy sector vulnerability to climate change: A review , 2012 .

[146]  Danny H.W. Li,et al.  Assessment of climate change impact on building energy use and mitigation measures in subtropical climates , 2011 .

[147]  Nan Zhou,et al.  Estimating Total Energy Consumption and Emissions of China's Commercial and Office Buildings , 2008 .

[148]  Kadir Bakirci,et al.  Evaluation of the performance of a ground-source heat-pump system with series GHE (ground heat exchanger) in the cold climate region , 2010 .

[149]  Danny H.W. Li,et al.  Lighting and cooling energy consumption in an open-plan office using solar film coating , 2008 .

[150]  Ruzhu Wang,et al.  Energy supply concepts for zero energy residential buildings in humid and dry climate , 2011 .

[151]  B. Perers,et al.  Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings , 2010 .

[152]  Pichai Namprakai,et al.  Experimental studies of a new solar water heater system using a solar water pump , 2008 .

[153]  J. Kiviluoma,et al.  The complexity and challenges of determining GHG (greenhouse gas) emissions from grid electricity consumption and conservation in LCA (life cycle assessment) – A methodological review , 2011 .

[154]  M. Thring World Energy Outlook , 1977 .

[155]  Danijela Nikolić,et al.  A simulation appraisal of performance of different HVAC systems in an office building , 2011 .

[156]  Li Zhu,et al.  Comprehensive energy and economic analyses on a zero energy house versus a conventional house , 2009 .

[157]  Joseph C. Lam An analysis of residential sector energy use in Hong Kong , 1996 .

[158]  Seppo Junnila,et al.  Combining life cycle costing and life cycle assessment for an analysis of a new residential district energy system design , 2013 .

[159]  Karsten Voss,et al.  Net zero energy buildings: A consistent definition framework , 2012 .

[160]  H. Akbari,et al.  Cooling energy savings potential of reflective roofs for residential and commercial buildings in the United States , 1999 .

[161]  Brian Vad Mathiesen,et al.  The role of district heating in future renewable energy systems , 2010 .

[162]  Mohd Shiraz Aris,et al.  Energy saving technique for cooling dominated academic building: Techno-economic analysis of its application , 2014 .